PubMed Health⌕ Search

Biomedical subjects

P Anne Hiltner

Publications and source records attributed to P Anne Hiltner.

2 recordsLinked to original sources

In vivo inflammatory and wound healing effects of gold electrode voltammetry for MEMS micro-reservoir drug delivery device.

The in vivo biocompatibility and biofouling of gold electrodes for a microelectromechanical systems drug delivery device were investigated in a rodent model. The role of the applied voltage and gold electrolysis products in modulating the inflammatory response (biocompatibility), and the temporal adhesion of cellular populations onto macroscopic gold film electrodes (biofouling) were analyzed in reference to two controls, devices to which voltage was not applied (uncorroded) or voltage was applied to inert platinum electrodes (electrical controls). Voltammetry was applied to the gold surfaces once (day 4, 7, 14, 21, 28, 35, 42, or 49), while voltage of identical magnitude was applied to the electrical controls. An inflammatory response characterized by a rapid decrease of leukocyte concentration to control levels was observed 48 h following voltage application with no significant cell concentration difference (p > 0.05) between the corroded devices and electrical controls. The histological evaluation of the direct implant fibrous capsule showed comparable thickness of voltage applied and control specimens. The gold corrosion peak current showed no significant difference (p > 0.05) among peak values at all time points. It was concluded that gold electrode corrosion was biocompatible and its electrochemical performance was not hindered by fibrous capsule formation.

Animals↗

Macrophage behavior on surface-modified polyurethanes.

Adherent macrophages and foreign body giant cells (FBGCs) are known to release degradative molecules that can be detrimental to the long-term biostability of polyurethanes. The modification of polyurethanes using surface modifying endgroups (SMEs) and/or the incorporation of silicone into the polyurethane soft segments may alter macrophage adhesion, fusion and apoptosis resulting in improved long-term biostability. An in vitro study of macrophage adhesion, fusion and apoptosis was performed on polyurethanes modified with fluorocarbon SMEs, polyethylene oxide (PEO) SMEs, or poly(dimethylsiloxane) (PDMS) co-soft segment and SMEs. The fluorocarbon SME and PEO SME modifications were shown to have no effect on macrophage adhesion and activity, while silicone modification had varied effects. Macrophages were capable of adapting to the surface and adhering in a similar manner to the silicone-modified and unmodified polyurethanes. In the absence of IL-4, macrophage fusion was comparable on the modified and unmodified polyurethanes, while macrophage apoptosis was promoted on the silicone modified surfaces. In contrast, when exposed to IL-4, a cytokine known to induce FBGC formation, silicone modification resulted in more macrophage fusion to form foreign body giant cells. In conclusion, fluorocarbon SME and PEO SME modification does not affect macrophage adhesion, fusion and apoptosis, while silicone modification is capable of mediating macrophage fusion and apoptosis. Silicone modification may be utilized to direct the fate of adherent macrophages towards FBGC formation or cell death through apoptosis.

Apoptosis↗