PubMed Health⌕ Search

Biomedical subjects

P Ask

Publications and source records attributed to P Ask.

At least 37 records · Page 2Linked to original sources

Bio-acoustic signals from stenotic tube flow: state of the art and perspectives for future methodological development.

To study the degree of stenosis from the acoustic signal generated by the turbulent flow in a stenotic vessel, so-called phonoangiography was first suggested over 20 years ago. A reason for the limited use of the technique today may be that, in the early work, the theory of how to relate the spectrum of the acoustic signal to the degree of the stenosis was not clear. However, during the last decade, the theoretical basis for this and other biological tube flow applications has been clarified. Now there is also easy access to computers for frequency analysis. A further explanation for the limited diagnostic use of bio-acoustic techniques for tube flow is the strong competition from ultrasound Doppler techniques. In the future, however, applications may be expected in biological tube flow where the non-invasive, simple and inexpensive bio-acoustic techniques will have a definite role as a diagnostic method.

Acoustics↗

Regurgitant heart valve flow from 2-D proximal velocity field: continued search for the ideal method.

It has been suggested that flow through a leaking heart valve can be determined by studying the proximal velocity field. Normally, only the centre-line velocity is studied as a potential method. The aim of the study is to improve this method by using information from the entire reconstructed proximal velocity field. Four methods are compared: use of the centre-line velocity; use of velocities at three different angles; integration of velocities over a hemisphere; and integration of velocities over an estimated hemi-elliptical isovelocity line. Measurements are performed in a hydraulic model with 4, 6 and 8 mm circular orifices, and these are compared with those from computer simulation. From the results presented in the study, it is suggested that the velocities should be integrated over a hemisphere within a best zone. This zone is dependent on the instrument settings, but in this case it is positioned 1.2-1.4 orifice diameters from the orifice inlet, with an angle of up to +/- 45 degrees from the centre axis, and contains velocities in the range 0.15-0.45 ms-1.

Blood Flow Velocity↗

A bioacoustic method for timing of respiration at cardiac investigations.

At cardiac investigations Doppler echocardiography is an established technique for the recording of intracardial and intravascular flow velocities. Transvalvular and venous flows are, however, markedly influenced by respiration. Since the start of inspiration is the important time of reference, accurate recording of the respiratory phase is important when analysing these flow velocities. A bioacoustic technique was therefore adopted to meet this demand and was tested in 10 normal subjects. Oesophageal balloon technique was used as a reference, and the bioacoustic technique was compared with a respiratory inductive plethysmograph. The average delay for the acoustic sensor signal compared to the oesophageal pressure changes was 205 +/- 46 (SD) ms, ranging from 160 to 320 ms for normal breathing, and is comparable to that of the respiratory inductive plethysmograph (210 +/- 90 ms). The bioacoustic technique is easier to apply than the respiratory inductive plethysmograph. The sensitivity to disturbances can be further reduced by signal processing and the method has clinical potential for the future.

Adult↗

Mathematical model that characterizes transmitral and pulmonary venous flow velocity patterns.

The transmitral and pulmonary venous flow velocity (TMFV and PVFV, respectively) patterns are related to the physiological state of the left heart by use of an electrical analog model. Filling of left ventricle (LV) through the mitral valve is characterized by a quadratic Bernoulli's resistance in series with an inertance. Filling of the left atrium (LA) through the pulmonary veins is represented by a lumped network of linear resistance, capacitance, and inertance. LV and LA are each represented by a time-varying elastance. A volume dependency is incorporated into the LV model to produce physiological pressure-volume loops and Starling curves. The state-space representation of the analog model consists of 10 simultaneous differential equations, which are solved by numerical integration. Model validity is supported by the following. First, the expected effects of aging and decreasing LV compliance on TMFV and PVFV are accurately represented by the model. Second, the model-generated TMFV and PVFV waveforms fit well to pulsed-Doppler recordings in normal and postinfarct patients. It is shown that the TMFV deceleration time is prolonged by the increase in LV compliance and, to a lesser extent, by the increase in LA compliance. A shift from diastolic dominance to systolic dominance in PVFV occurs when LA compliance or pulmonary perfusion pressure increases or when LV compliance or mitral valve area decreases. The present model should serve as a useful theoretical basis for echocardiographic evaluation of LV and LA functions.

Animals↗

Importance of collateral vessels in aortic coarctation: computer simulation at rest and exercise using transmission line elements.

Coarctation of the aorta causes arterial hypertension in the upper body and a low blood pressure downstream. Collateral blood vessels compensate by reducing the downstream pressure drop. To study the effect of various coarctation and collateral properties, we designed a computer model of the arterial circulation. The model contains a flow source and a library of subroutines for the lines and connectors. Distributed friction and wall viscoelasticity effects are included. Computer simulation was performed, using published values for vessel dimensions, in an arterial model with a coarctation and one lumped collateral. Rest and two levels of exercise (by increased heart rate) were studied. Without a collateral, we found the downstream pressure of the model was extremely dependent on the size of the coarctation. A collateral vessel reduced the pressure difference between the up- and downstream circulations. For a severe coarctation, the length and the diameter of the collateral were the main factors determining the downstream pressure and flow, whereas wall stiffness of the collateral had little influence. The relationship between mean pressure drop and cardiac output in coarctation was also dependent on the peripheral resistance in different flow beds, especially during exercise.

Aortic Coarctation↗

Vascular characteristics influence the aortic ultrasound Doppler signal: computer and hydraulic model simulations.

There is an increasing demand for non-invasive methods for the assessment of left ventricular function. Ultrasound Doppler methods are promising, and the early systolic flow velocity signal immediately distal to the aortic valve has been used clinically for this purpose. However, the signal is influenced not only by left ventricular ejection but also by systemic vascular characteristics. Their relative contribution to the time-velocity signal has not been analysed in depth previously. A theoretical analysis, based on a three-element Windkessel model, neglecting peripheral outflow in early systole and assuming linear pressure rise, was therefore tested in computer and hydraulic model simulations where peripheral outflow was included. Significant changes in early aortic flow velocity parameters were found when vascular characteristics were altered. As predicted by the theory, with a standardized aortic valve area and aortic pressure change, the simulations confirmed that maximal flow velocity is related to compliance of the aorta and the large arteries, and that maximal acceleration is inversely related to the characteristic impedance of the aorta. Therefore, maximal velocity and acceleration can be used for assessment of left ventricular function only in situations where vascular characteristics can be considered relatively constant or where they can be estimated.

Aorta↗

Coarctation of the aorta--a theoretical and experimental analysis of the effects of a centrally located arterial stenosis.

Aortic coarctation is a local constriction of the aorta that may severely affect haemodynamics. It is therefore important to quantify these effects. Using Bernoulli's equation and the momentum theorem, the pressure drop is described including the pressure recovery distal to the coarctation and the effects of collateral flow; both laminar and turbulent. Assuming the coarctation and collaterals to be stiff, a quadratic relationship between flow and pressure drop is expected for flow through the coarctation and for turbulent collateral flow. For laminar collateral flow, a linear relationship is expected. The coarctation flow was studied in a model consisting of a rigid tube with local constriction, connected to a flooded-level tank, containing a 36 per cent by weight solution of sucrose, with a viscosity equivalent to that of blood at body temperature. The pressure drop across the constriction showed a quadratic relationship to flow in agreement with theoretical expectations. Pressure recovery in this model was very slight (0-4 mm Hg). Nine patients with aortic coarctation were catheterised. Cardiac output and pressure drop across the coarctation were measured at rest and during supine cycle exercise at two different workloads. The relationship between mean pressure drop and cardiac output tended to be either 'parabolic' or, in some cases, approximately linear, suggesting that the flow situation in aortic coarctation can be quantified by expressions that either linearly or quadratically relate pressure and flow.

Adult↗

Analysis of different methods of assessing the stenotic mitral valve area with emphasis on the pressure gradient half-time concept.

There are 2 different theoretical models that analyze factors influencing the transmitral pressure gradient half-time (T1/2), defined as the time needed for the pressure gradient to reach half its initial value. In this report the models and the assumptions inherent in them were summarized. One model includes left heart chamber compliance, the other does not. Although the models at a superficial glance seem to be contradictory, the conclusions drawn from them are similar: i.e., T1/2 is influenced not only by valve area, but also by initial maximal pressure gradient and by flow. Different clinical situations in which the T1/2 method for valve area estimation has been shown not to work are analyzed in the 2 models. It is concluded that these models have contributed to our understanding of the T1/2 concept and when it should not be used. We also advocate use of the continuity equation in these situations, since no assumptions then need be made.

Blood Flow Velocity↗

Estimation of elastic properties in the urethral flow controlling zone by signal analysis of urodynamic pressure/flow data.

When urethral flow is treated as a lossless flow through an elastic tube, the relationship between the detrusor pressure and the urinary flow can be related to the elasticity of the flow-controlling zone of the urethra. A recent analytical method of describing urethral elasticity is implemented on a computer. The function p(Q) = pmo + LmQm is fitted to the recorded pressure/flow data. p(Q) is the detrusor pressure, Q the flow and pmo, m and Lm parameters. The elastic properties are then obtained as p(A) = pmo + KnAn, where p(A) is the static pressure, A the cross-sectional area of the flow-controlling zone and n and Kn calculated parameters. The urodynamic methods used and the computer implementation of the analytical method are described. In obstructed and unobstructed men without neurological symptoms, the elastic properties could be estimated in 94 per cent of the micturitions. The method makes it possible to describe urethral flow properties with Griffiths' model in a standardised way and compare results obtained by different investigators. It is recommended for quantification of urethral obstruction in research and for assessment of borderline cases of obstruction in clinical practice.

Biomechanical Phenomena↗

Measurement techniques for urodynamic investigations.

Important measurement techniques for investigating lower urinary tract function are flow and pressure measurements. The demands on urinary flowmeters and the measurement principles of balance type, rotating disc, dipstick, and air-displacement type are described. Urological pressure measurements are performed in the bladder, in the urethra, and in the abdominal cavity. Various fluid-filled and microtransducer systems are reviewed and demands for performance given. Differences in measuring a mechanical pressure, like in the urethra, and a fluid pressure in the bladder are discussed. Electromyography (EMG) technique is used to investigate various neurological disturbances in the lower urinary tract. The electrode technique is also described. Furthermore, techniques for incontinence detection are reviewed.

Humans↗

Problems related to the assessment of fluid velocity and volume flow in valve regurgitation using ultrasound Doppler technique.

Understanding of the factors affecting regurgitant flow through a heart valve and of the inherent limitations of the Doppler technique is needed to interpret correctly the information obtained during an ultrasound Doppler examination. This paper describes the flow conditions at the leaking valve and limitations of the Doppler technique which become important in the case of valve regurgitation. The flow conditions can be described in the following terms: contraction of the flow, core flow dimensions, friction, and intrusion and width of the jet flow. Contraction occurs at the entrance to the orifice and causes the width of the jet at the orifice to be smaller than the orifice itself. This contraction should be taken into account when calculating volume flow. The jet reaches a minimal area at the vena contracta where the flow velocity is close to that expected from the Bernoulli equation. The area of the vena contracta relative to the area of the hole can vary between 0.6 and 1.0; the lowest value is seen at a sharp-edged orifice and the highest value, at a hole with an ideally rounded inlet. Friction has a marginal role on flow velocity at the vena contracta. The velocity at the vena contracta persists in a region called the core flow region. This region has a length of 4-8 hole diameters. The total jet intrusion and the width of the jet are related to both the flow velocity at the hole and the diameter of the hole.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

Peripheral nerve as an osmometer: role of endoneurial capillaries in frog sciatic nerve.

The sciatic nerve of the frog was perfused in vivo with isotonic Ringer solution followed by Ringer made hypertonic by addition of sucrose or of NaCl. Nerve diameter and endoneurial hydrostatic pressure fell during hypertonic Ringer perfusion. Using a model that describes the elastic and osmotic properties of the nerve, sigma sLp, the product of the osmotic reflection coefficient at endoneurial capillaries for s equals sucrose or NaCl (which approximates 1), and of capillary hydraulic conductivity, was found to equal 73 X 10(-13) cm3 X s-1 X dyn-1. The nerve is elastic. It has a compliance K of 3.7 X 10(-5) cm2 X mmHg-1, corresponding to a modulus of elasticity E of the perineurium equal to 1.2 X 10(6) dyn X cm-2. The results indicate that the nerve behaves as an osmometer during vascular perfusion, due to the low permeability of endoneurial capillaries to small solutes such as NaCl and sucrose. A low capillary hydraulic conductivity limits bulk water flow between blood and nerve, and a low compliance limits nerve swelling and edema.

Animals↗

Electromyography of human oesophageal smooth muscle.

The aim was to study whether electromyography (EMG) activity is synchronous with oesophageal motor activity as assessed by manometry from the same oesophageal site. Patients with different motor disorders of the oesophagus and control subjects were investigated. EMG recordings were made by means of a suction capsule with silver/silver chloride spike electrodes. Slow EMG waves synchronous with respiration were recorded from the lower oesophageal sphincter and intermittently from the body of the oesophagus. Edrophonium increased spike discharges; atropine diminished or abolished spike discharges after swallowing. Swallowing caused a burst of spiking activity which began immediately after deglutition. Continuous sips of water produced constant EMG activity but no peristaltic contractions as seen by manometry. In a patient with scleroderma and aperistalsis, swallowing elicited vigorous electrical activity. The different EMG findings without simultaneous contractions at manometry are interpreted as a response to a swallow by the longitudinal muscle of the oesophagus.

Animals↗

Oesophagitis, signs of reflux, and gastric acid secretion in patients with symptoms of gastro-oesophageal reflux disease.

In a study comprising 100 patients referred to a surgical clinic with symptoms suggestive of gastro-oesophageal reflux disease the value of different diagnostic procedures was investigated. Positive acid perfusion and 24-h pH tests were the commonest findings. Forty-nine per cent showed a normal oesophageal mucosa or diffuse oesophagitis at endoscopy. The severity of heartburn and regurgitation did not differ between patients with normal oesophageal mucosa and oesophagitis of various severities. The severity of macroscopic oesophagitis was significantly correlated to the total reflux time, the presence of reflux or a hiatal hernia at radiology, an open cardia or reflux at endoscopy, pressure transmission or reflux and low lower oesophageal sphincter pressure at manometry. Gastric hypersecretion was found in 66% of the patients. Gastric acid secretion was not correlated to the severity of oesophagitis or to the findings at 24-h pH test. In patients with severe oesophagitis the sensitivity for radiologic, manometric, and endoscopic signs of incompetence of the gastro-oesophageal junction was 94%.

Adult↗

Quantification of heart valve regurgitation: a critical analysis from a theoretical and experimental point of view.

A theoretical analysis is presented regarding factors of importance for the determination of distance of intrusion of the regurgitant jet in heart valve regurgitation. The analysis is based on hydrodynamic theory. In the idealized model situation, for a circular hole, the intrusion of the regurgitant jet is linearly related to the product of the fluid mean velocity in the orifice and the diameter of the orifice. This was also shown to be true in an experimental fluid model. Thus, volume regurgitation cannot be quantified by the measurement of distance of intrusion of the regurgitant jet alone. On the other hand, an estimate of volume regurgitation can, in the idealized situation, be obtained if mean fluid velocity in the orifice, distance of intrusion of the jet and regurgitation time are known.

Aortic Valve Insufficiency↗