Extension of a state-of-the-art optimization criterion to predict co-contraction.

Most studies concerned with the prediction of muscle forces have tried to predict a physiologically reasonable, synergistic muscle behavior. In addition to the load sharing of synergistic muscles, co-contraction of antagonistic muscles also occurs. An extension to a standard quadratic criterion for the calculation of muscle forces is presented in this study. This extension however is not limited to quadratic optimization. The extension is applied to a planar, one degree of freedom model of the human knee. For this model an analytical solution is presented. With the extended criterion it was possible to predict and control the amount of co-contraction for the knee model. The enforced antagonistic muscle activity led to higher agonistic muscle activity. In the absence of an external load flexor and extensor muscles were activated. As a consequence the knee joint was preloaded. This might indicate that antagonistic muscle activity is generated to maintain or improve joint stability. In conclusion, this study presents a novel approach to predict co-contraction when using optimization techniques to determine muscle forces by introducing a shift parameter for the optimization criterion.

Humans↗

Influence of diclofenac (group of nonsteroidal anti-inflammatory drugs) on fracture healing.

INTRODUCTION: Nonsteroidal antirheumatics (NSAR; NSAID) are often used in patients with fractured bones for analgetic reasons. This animal experiment was performed to determine the influence of NSAR on the process of fracture healing. As an alternative, tramadol, the centrally acting analgetic without peripheral effects, was included in this experiment. MATERIALS AND METHODS: Wistar rats were operated on by a transverse osteotomy of the proximal tibia of the left leg. The fracture was stabilized by intramedullary nailing (healing period 21 days). All drugs were applied orally twice a day. The animals were divided into four groups with 10 rats each: Group 1 was treated with placebo (P), group 2 with tramadol (T; 20 mg/kg body weight/day), group 3 with diclofenac sodium (DS; 5 mg/kg bw/day) for 7 days followed by 14 days of placebo, group 4 with diclofenac sodium (DL; 5 mg/kgbw/day) over 21 days. On day 21 the rats were killed, and each leg was examined by X-ray, then the tibia was examined by CT scan, three-point bending, and histology. RESULTS: The results of CT and three-point bending showed that rats treated by diclofenac presented with delayed fracture healing compared with those treated by placebo or tramadol. Bone density in CT was highest in group 1 (mean 611.4+/-50.1 mg/ml), followed by group 2 (mean 542.5+/-29.5 mg/ml). Groups 3 (mean 411+/-34.0 mg/ml; p=0.006) and 4 (mean 395.2+/-15.4 mg/ml; p=0.009) were significantly lower. The stability of the bones, as measured by the breaking force ( F(max)), was highest in group 1 (mean 45.8+/-19.0 N), followed by group 2 (mean 39.0+/-7.9 N; NS); group 3 (mean 20.6+/-7.8 N; p=0.01) was significantly lower than the placebo animals, followed by group 4 (mean 26.5+/-8.3 N; p=0.03). Similar results were shown for bending stiffness: group 1 (mean 1404.6+/-611.4 Nmm/mm), group 2 (mean 1033.2+/-232.1 Nmm/mm; NS), group 3 (mean 564.2+/-457 Nmm/mm; p=0.045), and group 4 (mean 494.8+/-340.2 Nmm/mm; p=0.028). There were no significant differences between groups 1 and 2 and between groups 3 and 4, respectively. Diclofenac serum levels on day 21 in rats with long-term diclofenac application (mean 301.4+/-83.3 ng/ml) were comparable to those in humans. CONCLUSION: Oral application of diclofenac significantly delayed fracture healing in rats. This effect might be comparable to other NSAR and fracture healing in humans.

Analgesics, Opioid↗

Influence of the stiffness of bone defect implants on the mechanical conditions at the interface--a finite element analysis with contact.

The study focused on the influence of the implant material stiffness on stress distribution and micromotion at the interface of bone defect implants. We hypothesized that a low-stiffness implant with a modulus closer to that of the surrounding trabecular bone would yield a more homogeneous stress distribution and less micromotion at the interface with the bony bed. To prove this hypothesis we generated a three-dimensional, non-linear, anisotropic finite element (FE) model. The FE model corresponded to a previously developed animal model in sheep. A prismatic implant filled a standardized defect in the load-bearing area of the trabecular bone beneath the tibial plateau. The interface was described by face-to-face contact elements, which allow press fits, friction, sliding, and gapping. We assumed a physiological load condition and calculated contact pressures, shear stresses, and shear movements at the interface for two implants of different stiffness (titanium: E=110GPa; composite: E=2.2GPa). The FE model showed that the stress distribution was more homogeneous for the low-stiffness implant. The maximum pressure for the composite implant (2.1 MPa) was lower than for the titanium implant (5.6 MPa). Contrary to our hypothesis, we found more micromotion for the composite (up to 6 microm) than for the titanium implant (up to 4.5 microm). However, for both implants peak stresses and micromotion were in a range that predicts adequate conditions for the osseointegration. This was confirmed by the histological results from the animal studies.

Animals↗

Correlation of bone mineral density with strength and microstructural parameters of cortical bone in vitro.

The aim of this study was to evaluate the influence of microstructural parameters, such as porosity and osteon dimensions, on strength. Therefore, the predictive value of bone mineral density (BMD) measured by quantitative computed tomography (QCT) for intracortical porosity and other microstructural parameters, as well as for strength of cortical bone biopsies, was investigated. Femoral cortical bone specimens from the middiaphysis of 23 patients were harvested during total hip replacement while drilling a hole (dia. 4.5 mm) for the relief of the intramedullary pressure. In vitro structural parameters assessed in histological sections as well as BMD determined by quantitative computed tomography were correlated with yield stress, and elastic modulus assessed by a compression test of the same specimens. Significant correlations were found between BMD and all mechanical parameters (elastic modulus: r = 0.69, p < 0.005; yield stress: r = 0.64, p < 0.005). Significant correlations between most structural parameters assessed by histology and yield stress were discovered. Structural parameters related to pore dimensions revealed higher correlation coefficients with yield stress (r = -0.69 for average pore diameter and r = -0.62 for fraction of porous structures, p < 0.005) than parameters related to osteons (r = 0.60 for osteon density and average osteonal area, p < 0.005), whereas elastic modulus was predicted equally well by both types of parameters. Significant correlations were found between BMD and parameters related to porous structures (r = 0.85 for porosity, 0.80 for average pore area, and r = 0.79 for average pore diameter in polynomial regression, p < 0.005). Histologically assessed porosity correlated significantly with parameters describing porous structures and haversian canal dimensions. Our results indicate a relevance of osteon density and fraction of osteonal structures for the mechanical parameters of cortical bone. We consider the measurement of BMD by quantitative computed tomography to be helpful for the estimation of bone strength as well as for the prediction of intracortical porosity and parameters related to porous structures of cortical bone.

Aged↗

Interaction of fibronectin and aggregation substance promotes adherence of Enterococcus faecalis to human colon.

This in vitro study investigates the interaction between aggregation substance (AS), a virulence factor of Enterococcus faecalis, and colonic mucosal fibronectin in normal colon and colon from patients with Crohn's disease. Fibronectin was found to be overexpressed in Crohn's disease compared to normal colon. Compared to E. faecalis OG1X:pAM944 (AS-negative), E. faecalis OG1X:pAM721 (expressing AS) showed a significantly enhanced adhesion to human colonic mucosa in normal colon and in colon from patients with Crohn's disease. Double-staining of fibronectin and AS-positive enterococci showed that colocalization of bacteria and fibronectin was significantly more frequent in Crohn's disease than in normal colon. Preincubation of bacteria with soluble fibronectin caused a significant reduction in the adherence to fibronectin. In conclusion, the interaction between AS and fibronectin plays is an important factor that mediates adhesion of Enterococcus faecalis to colonic mucosa. This might be one of the mechanisms responsible for bacterial translocation of Enterococcus faecalis.

Bacterial Adhesion↗

A new bioresorbable polymer for screw augmentation in the osteosynthesis of osteoporotic cancellous bone: a biomechanical evaluation.

The aim of the study was to assess the mechanical efficacy of a new resorbable polymer developed on the basis of alkylene bis(dilactoyl)-methacrylate to improve the anchorage of osteosynthesis material in cancellous bone. Cancellous bone screws were inserted in bovine as well as in human vertebrae and human femoral condyles and were augmented with the new polymer or polymethylmethacrylate (PMMA), respectively. Nonaugmented screws were used as controls. A removal torque test, a dynamic fatigue test, and a pullout test were performed. Augmentation with the new polymer increased the removal torque by 84% in human femoral bone. In the dynamic fatigue test of bovine vertebrae, the removal torque after cyclic loading was 115% higher for the new polymer compared to the nonaugmented controls. In the human vertebrae, the reinforcement with the new polymer increased the removal torque after dynamic loading by 114%. The augmentation with the new polymer increased the pullout force by 88% in bovine vertebrae and by 118% in human vertebrae in comparison to nonaugmented screws. It was concluded that augmentation by the new resorbable polymer significantly enhanced the anchorage of bone screws in cancellous bone. The mechanical efficiency of the new polymer was comparable to that of PMMA cement.

Aged↗

Prediction of cortical bone porosity in vitro by microcomputed tomography.

The high importance of intracortical porosity for mechanical strength of cortical bone has been established. The contribution of other parameters of microstructure such as osteon dimensions for strength is in discussion. The aim of this study was to evaluate the predictive value of microcomputed tomography (mCT) for porosity and other microstructural parameters of cortical bone in cortical bone biopsies. Femoral cortical bone specimens from the middiaphysis of 24 patients were harvested during the procedure of total hip replacement at the location where normally one hole (Ø 4.5 mm) for the relief of the intramedullary pressure is placed. In vitro intracortical porosity and bone mineral density (BMD) measurements by mCT were compared with structural parameters assessed in histological sections of the same specimens. A strong correlation was found between intracortical porosity measured by mCT and histological porosity (r = 0.95, P <0.0001). Porosity measured by mCT was also a strong predictor for other parameters describing dimensions of porous structures. BMD?1 was associated with osteonal area (r = -0.76, P <0.0001). We consider the measurement of porosity by mCT as a very potent procedure for assessing intracortical porosity and parameters related to porous structures of cortical bone nondestructively in vitro.

Aged↗

Composites made of rapidly resorbable ceramics and poly(lactide) show adequate mechanical properties for use as bone substitute materials.

Porous composite materials made of poly(L, DL-lactide) and a ceramic component, alpha-tricalcium phosphate (alpha-TCP) or one of the rapidly resorbable glass ceramics, GB9N or GB14N, respectively, were developed to be used as bone substitutes. The present article describes the mechanical properties and the in vitro degradation characteristic of the different composite materials. The yield strength, the elastic modulus, and the molecular weight were measured after in vitro degradation up to 78 weeks. The initial strengths of the alpha-TCP composite (12.5 +/- 0.7 MPa) was higher than that of the GB9N and GB14N composites (8.3 +/- 0.2 MPa and 10.9 +/- 0.2 MPa, respectively). The initial elastic moduli of the composites were between 450 and 650 MPa. The mechanical properties remained constant until a degradation period of 26 weeks. Then they decreased continuously until they were completely lost at week 52. The molecular weight (M(w)) decreased steadily from 91,000 D in the case of the alpha-TCP composite and 78,000 D and 85,000 D in the case of the GB9N or GB14N composites, respectively, to about 10,000 D at week 78. It was concluded that the composites show adequate mechanical properties in the range of cancellous bone and a suitable degradation characteristic to be used as bone substitute materials.

Animals↗

In vivo investigations on composites made of resorbable ceramics and poly(lactide) used as bone graft substitutes.

Porous composites made of poly(L, DL-lactide) (PLA) and alpha-tricalcium phosphate (alpha-TCP) or the glass ceramic, GB14N, respectively, were investigated in a loaded implant model in sheep. Six, 12 and 24 months after implantation histological and biomechanical evaluation were performed and compared to autogenous bone transplants. No significant differences were observed between the composites. After 6 months, the interconnecting pores of the alpha-TCP-composite and the GB14N-composite were filled with newly formed bone (14 +/- 5% or 29 +/-15% of the implant, respectively) and soft tissue (30 +/-9% or 21 +/-12% of the implant, respectively). Only a mild inflammatory response was observed. The reaction was similar after 12 months. However, after 24 months a strong inflammatory reaction was seen. The newly formed bone was partly osteolytic. The adverse reaction occurred simultaneously to a significant reduction of the PLA component. The histological results were reflected by the biomechanical outcomes. Both composites showed compression strengths in the range of the autologous bone graft until 12 months of implantation. After 2 years, however, the strengths were significantly decreased. It is concluded that the new composites cannot yet be used for clinical application. An improvement in biocompatibility might be reached by a better coordination of the degradation times of the polymer and the ceramic component.

Absorbable Implants↗

The effect of micromovement on callus formation.

Micromovement at fracture sites is known to promote callus formation and bridging of the bony fragments. The present study was conducted to identify the suitable amount of micromovement, and to analyze the location and timing of callus proliferation. A standardized transverse osteotomy, in the right metatarsus of 32 sheep, was used as a fracture model. The osteotomy was externally fixed with a special ring fixator, which allowed axial micromovements of defined sizes. The animals were divided into four groups, with gaps of 2 mm and 6 mm, and micromovements of 0.3 mm and 0.7 mm, respectively. The labeling of new bone formation was performed by the intravenous injection of calcein green in the fourth week and tetracycline in the eighth week. Nine weeks postoperatively the sheep were killed. The explanted metatarsals were radiographed for the measurement of the periosteal callus area and were nondestructively loaded in a three-point bending test to determine their flexural rigidity. Histological analysis of undecalcified bone was performed in bone slices in the sagittal plane. Fluorescent green (callus formed in the fourth week) and yellow areas (callus formed in the eighth week) and the area of connective tissue were determined, using fluorescence microscopy. Bone formation was larger in the eighth week than that in the fourth week in all groups. In the fourth week, large micromovements in the small gap resulted in increased bone formation, whereas, for large gaps, the large micromovements diminished new bone formation. With large micromovement, the amount of newly formed bone within the gap decreased with increasing gap size, suggesting a delay of bone healing. Stimulation of new bone formation by micromovement was mainly effective in the early healing phase (4 weeks postoperatively). Large gaps showed the least new bone formation at the fracture site and the lowest flexural rigidity. From the histological analysis, it was found that the flexural rigidity correlated with the new bone area in the periosteal region.

Animals↗

Prediction of strength of cortical bone in vitro by microcomputed tomography.

OBJECTIVE: The aim of this study was to evaluate the predictive value of bone mineral density and intracortical porosity measured by microcomputed tomography for the strength of cortical bone biopsies. DESIGN: Experimental study comparing the predictive value of bone mineral density and of intracortical porosity determined in vitro by microcomputed tomography for the mechanical properties of cortical bone cylinders. BACKGROUND: The assessment of cortical bone strength might be relevant for the prediction of fracture risk or the choice of suitable therapy strategies in orthopaedic surgery. The predictive value of cortical density for the mechanical properties is discussed controversially. The relevance of intracortical porosity measured by histomorphometry has been established, but the predictive value of porosity determined by microcomputed tomography remains to be explored. METHODS: Femoral cortical bone specimens from the mid diaphysis of 24 patients were harvested during total hip replacement procedure at the location, where a diaphyseal hole (diameter 4.5 mm) was drilled in order to reduce the intramedullary pressure. In vitro intracortical porosity and bone mineral density measurements by microcomputed tomography were compared with strength and elastic modulus assessed by a compression test transverse to the Haversian systems of the same specimens. RESULTS: Significant negative correlations were found between porosity measured by microcomputed tomography scans and yield stress, stiffness and elastic modulus (P<0.001), however, the positive correlations between bone mineral density and mechanical parameters were stronger (P<0.0001). The mechanical parameter best predicted by mineral density as well as by porosity was yield stress (r=0.72,P<0.0001;r=-0.64,P<0.001). CONCLUSIONS: Bone mineral density determined by microcomputed tomography imaging in vitro may be a potent method to predict mechanical properties of cortical bone non-destructively. The application in vivo remains to be explored.

Aged↗

Predictive value of Singh index and bone mineral density measured by quantitative computed tomography in determining the local cancellous bone quality of the proximal femur.

OBJECTIVE: The purpose of this study was to assess the predictive value of the Singh index as well as quantitative computed tomography for the in vitro local mechanical competence of the cancellous bone of the proximal femur. DESIGN: An experimental study examining the relation between mechanical properties and bone mineral density of the femoral neck determined in vitro and the clinical estimated Singh index on X-rays. BACKGROUND: Evaluation of the predictive value of the Singh index, an inexpensive and simple technique for the mechanical properties of the cancellous bone of the proximal femur. METHODS: The bone quality of the proximal femur of 34 patients undergoing total hip replacement was estimated by roentgenography using the Singh index. Bone mineral density was quantified by quantitative computed tomography using cylindrical cancellous bone biopsies harvested during the total hip replacement procedure by a new biopsy method. The mechanical properties of the bone specimens (Young's modulus, strength and maximum energy absorption E(max)) were measured by mechanical testing of the bone biopsies. RESULTS: A strong correlation of the Singh index versus material properties of cancellous bone was noted (r=0.66 for Young's modulus, r=0.73 for strength and r=0.69 for E(max), P<0.0001). The correlations of bone mineral density measured by quantitative computed tomography versus Young's modulus, strength and energy absorption E(max) were significant. Strength was predicted best (r=0.82; P<0.0001), followed by E(max) (r=0.79; P<0.0001) and Young's Modulus (r=0.73; P<0.0001). CONCLUSIONS: We conclude, that assessment of bone mineral density by quantitative computed tomography is a reliable and precise method for the estimation of cancellous bone material properties. The Singh index provides a rough estimate for the mechanical competence of the proximal femur. It is inexpensive, simply to assess and can in some cases replace the measurement of bone mineral density, notably in cases of marked decrease in bone density.

Aged↗

Predictive value of bone mineral density and morphology determined by peripheral quantitative computed tomography for cancellous bone strength of the proximal femur.

Peripheral quantitative computed tomography (pQCT) is an established diagnostic method for assessment of bone mineral density in the diagnosis of osteoporosis. However, the capacity of structural parameters of cancellous bone measured by high-resolution computed tomography remains to be explored. In 33 patients, bone mineral density (BMD) of the proximal femur was measured in vitro by pQCT using cylindrical biopsies from the intertrochanteric region harvested before the implantation of an artificial hip joint. By digital image analysis of CT scans, parameters derived from histomorphometry describing the microarchitecture of cancellous bone were measured. The biopsies were also loaded to failure by an uniaxial compression test to determine the biomechanical parameters, Young's modulus, strength, and maximum energy absorption (E(max)). Strong correlations were found for BMD vs. mechanical parameters (r = 0.73 for Young's modulus, r = 0.82 for strength, and r = 0.79 for E(max); p < 0.001, n = 29). The morphological parameters, bone volume per trabecular volume (BV/TV), apparent trabecular thickness (app.Tb.Th), apparent trabecular separation (app.Tb.Sp), and trabecular number (Tb.N), correlated significantly with all mechanical parameters. The combination of morphological parameters with BMD in a multivariate regression model led to an overall, but only moderate, increase in R(2) in all cases. Our data confirm the high predictive value of BMD for the mechanical competence of cancellous bone of the intertrochanteric region. However, quantification of cancellous bone structure by image analysis of CT scans may provide additional qualitative information for the analysis of bone strength.

Aged↗

Effects of high-frequency, low-magnitude mechanical stimulus on bone healing.

Recent studies have shown osteogenic effects of high-frequency mechanical stimuli. The purpose of this study was whether externally applied, high-frequency, low-magnitude interfragmentary movements affect the process of bone healing. In 12 sheep, a transverse osteotomy with a 3 mm gap was created in the right metatarsus and externally stabilized by a rigid circular fixator. External stimulation was performed in six sheep with the use of ground-based vibration. The sheep were standing with their hind limbs on a platform that produced vertical movements resulting in interfragmentary movements of approximately 0.02 mm magnitude at 20 Hz frequency. The other six sheep remained rigidly stabilized by external fixation during the 8-week study and served as a control group. Healing was assessed postmortem by densitometric and mechanical examinations. No significant differences were found between the two groups, although callus formation was slightly enhanced (11%) in the stimulated group compared with the control group. Mechanical stimuli attributable to weightbearing in the control group were sufficient enough to initiate callus formation even under rigid, external fixation. Thus, external mechanical stimulation with the stimulation design described in the current study might not be indicated for improvement of bone healing.

Animals↗

Mechanical stimulation by external application of cyclic tensile strains does not effectively enhance bone healing.

OBJECTIVE: To determine whether an externally induced interfragmentary movement enhances the healing process of a fracture under flexible fixation. DESIGN: Randomized, prospective in vivo animal study with control group. Twenty-four skeletally mature Merino sheep were randomly assigned to six groups of four animals, which received cyclic interfragmentary movements of 0.2 and 0.8 millimeters and stimulation frequencies of 1, 5, and 10 Hertz, respectively. Twelve animals did not receive any externally applied stimulation and served as a control group. SETTING: Unrestricted stall activity with weight bearing reduced by tenotomy of the Achilles tendon. INTERVENTIONS: Osteotomy of the tibial diaphysis with three-millimeter gap width fixed with a six-pin, monolateral, double-bar external fixator. Interfragmentary movement of the osteotomy gap was externally induced by a motor-driven actuator unit. Five hundred cycles inducing nonuniform tensile strains within the gap were performed each day. MAIN OUTCOME MEASUREMENTS: Nine weeks after surgery, the animals were killed, and bone mineral density and callus cross-sectional area were measured with quantitative computed tomography. Callus projectional area was assessed by radiographs, and mechanical stability was determined with a three-point bending test. RESULTS: External stimulation with nonuniform cyclic tensile strains did slightly affect but not significantly enhance the fracture healing process. Varying the stimulation frequency had no influence on the healing process. The stimulation with 0.8 millimeter displacement magnitude resulted in a larger periosteal callus, but a decreased bone mineral density compared with the 0.2-millimeter displacement magnitude. The stimulation had no significant influence on the mechanical properties of the healing bone. CONCLUSIONS: Induced cyclic tensile strains did not produce a relevant enhancement of bone healing under flexible fixation.

Animals↗

Degradation behavior of composite pins made of tricalcium phosphate and poly(L,DL-lactide).

Combining a bioactive ceramic with a resorbable polymer may improve the biocompatibility and the osseointegration of degradable fracture fixation devices. This study reports on the mechanical properties and degradation behavior of two composite pins made of poly(L,DL-lactide) and 10 and 30% beta-tricalcium phosphate (TCP), respectively. The pins were compared to a pin made of 100% poly(L,DL-lactide). The failure force, bending strength, and molecular weight were determined during in vitro degradation at 37 degrees C up to 78 weeks. The blending with 10 or 30% beta-TCP decreased the initial mechanical properties and led to an accelerated degradation rate. The pins with 30% TCP lost half of their strength after 16 weeks, i.e. faster than the unmodified pin (40 weeks). The pins with 10% TCP, however, showed a decreased initial strength (128+/-9 MPa) compared to the unmodified pin (152+/-9 MPa) but very similar degradation characteristics. The drop of the molecular weight was not significantly different between the three types of pins. It was concluded that the mechanical requirements for a pin for the fixation of small bony fragments with improved biocompatibility were fulfilled by the composite pin with 10% TCP but not by the pin with 30% TCP.

Biocompatible Materials↗

[Mechanical modification of callus healing].

Interfragmentary movement and size of the fracture gap influence fracture healing. Limited movements promote callus formation and may result in increased mechanical stability. Although larger movements still promote callus formation, the bony consolidation of the fracture is hampered. Fracture healing is also hampered if the size of the fracture gap is too large. A combination of large movement and large gap bears the risk of non-union. Therefore, having in mind a minimally invasive surgical approach, one should strive for good reduction of the fracture ends and flexible yet stable osteosynthesis. Dynamization of the fracture by enabling axial movement will close the fracture gap, stimulate tissue differentiation and possibly accelerate the healing process. External mechanical stimulation, however, has not been shown to effectively enhance the healing process under flexible fixation or in load-bearing patients.

Animals↗