PubMed Health⌕ Search

Biomedical subjects

P Augat

Publications and source records attributed to P Augat.

At least 55 records · Page 3Linked to original sources

Morphometric texture analysis of spinal trabecular bone structure assessed using orthogonal radiographic projections.

The measurement of bone microstructure as well as bone mineral density may improve the estimation of bone strength. Cubic specimens (N = 26, 12 mm X 12 mm X 12 mm) of human cadaver vertebrae were cut along three orthogonal anatomic orientations, i.e., superior-inferior (SI), medial-lateral (ML), and anterior-posterior (AP). Contact radiographs of the bone cubes along all three orientations were obtained and then digitized by a laser scanner with pixel size of 50 microns x 50 microns. The specimens were tested in compression along the 3 orthogonal orientations and the Young's modulus (YM) was calculated for each direction. Quantitative computed tomography (QCT) was used to obtain a measure of trabecular bone mineral density (BMD). Global gray level thresholding and local thresholding algorithms were used to extract the trabecular bone network. Apparent trabecular bone fraction (ABV/TV), mean intercept length (I.TH), mean intercept separation (I.SP), and number of nodes (N.ND) were measured from the extracted trabecular network. Fractal dimension (Fr.D) of the trabecular bone texture was also measured. Paired t-tests showed that the mean values of each texture parameter (except ABV/TV) and of YM along the SI direction were significantly different (p < 0.05) from those along the ML and AP direction. However, the mean values along the ML and AP directions were not significantly different. Multivariate regression of YM as a function of the texture parameters and BMD showed that without adjusting for the effect of BMD, YM was significantly explained by all the texture parameters (R2 = 0.2-0.6). When BMD was included in the regression, although the variations in YM of ML, AP, and SI orientations could be explained by BMD alone, some of the texture parameters did improve the overall prediction of the biomechanical properties, while, some parameters such as ABV/TV and Fr.D in the ML orientation showed a more significant overall effect in explaining mechanical strength than did BMD. In conclusion, trabecular texture parameters correlated significantly with BMD and YM. Trabecular texture parameters from projectional radiographs reflect the anisotropy of trabecular structure. Quantitative radiographic assessment of trabecular structure using fine-detail radiography can potentially improve the estimation of bone strength.

Adult↗

Trochanteric hip fracture: strong association with spinal trabecular bone mineral density measured with quantitative CT.

PURPOSE: To determine the discriminatory capability for hip fracture of trabecular and integral bone mineral density (BMD) measured with quantitative computed tomography (CT) of the spine. MATERIALS AND METHODS: Fifty-six women who had sustained hip fractures and 59 control subjects underwent volumetric quantitative CT of L1 and L2 and dual x-ray absorptiometry of the hip. BMD was measured in vertebral regions of interest that encompassed trabecular, cortical, and integral bone. Logistic regression analysis was applied to each BMD measure to derive age-, weight-, and height-adjusted relative risk (RR) factors for overall hip fracture and for trochanteric fracture and cervical fracture separately. RESULTS: Spinal trabecular BMD was modestly related to overall hip fracture (RR, 1.4-1.7; P < .05) and strongly associated with trochanteric fracture (RR, 4.2-4.5; P < .005). Spinal integral BMD related similarly to overall hip fracture (RR, 1.7-1.8; P < .05) but more weakly to trochanteric fracture (RR, 2.3-3.2; P < .01). No spinal BMD measures were significantly related to cervical fracture. BMD at the hip was strongly related to overall hip fracture (RR, 3.3-4.3; P < .001), cervical fracture (RR, 2.7-5.3; P < .001), and trochanteric fracture (RR, 2.9-7.2; P < .001). CONCLUSION: Spinal trabecular BMD is strongly associated with both trochanteric and vertebral fractures.

Absorptiometry, Photon↗

Proximal femur: assessment for osteoporosis with T2* decay characteristics at MR imaging.

PURPOSE: To use T2* measurements at magnetic resonance (MR) imaging to investigate the trabecular structure of the hip in women with and women without osteoporotic hip fractures and to compare this technique with bone mineral density (BMD) measurements in the diagnosis of fractures. MATERIALS AND METHODS: T2* maps of the proximal femur were obtained at 1.5 T in 23 postmenopausal study patients with osteoporotic hip fractures, 27 age-matched healthy postmenopausal control subjects, and five healthy premenopausal control subjects. A modified gradient-recalled acquisition in the steady state, or GRASS, sequence was used with echo times of 4-40 msec at 4-msec increments. T2* values were measured in five regions of interest: femoral neck, the Ward triangle, trochanter, intertrochanteric region, and total proximal femur. Additionally, BMD measurements of the hip were obtained with dual x-ray absorptiometry. RESULTS: Significant differences between T2* measurements were obtained in all three groups (P < .05). BMD measurements of the hip also showed significant differences (P < .05). For T2* and BMD measurements, odds ratios and areas under the curve in receiver operating characteristic analysis were comparable. Correlations between 1/T2* values and BMD were significant (P < .05). T2* measurements in the proximal femur showed regional variations. CONCLUSION: MR imaging decay characteristics of bone marrow could be used to differentiate between postmenopausal women with and those without osteoporotic hip fractures.

Absorptiometry, Photon↗

A comparative study of trabecular bone properties in the spine and femur using high resolution MRI and CT.

The purpose of this study was to use high resolution (HR) magnetic resonance (MR) and computed tomography (CT) images combined with texture analysis to investigate the trabecular structure of human vertebral and femoral specimens and to compare these techniques with bone mineral density (BMD) in the prediction of bone strength. Twenty-nine bone cubes were harvested from 12 proximal femur cadaver specimens and 29 from 8 spines. HR MR and CT images were obtained, and texture analysis techniques were used to assess trabecular structure. Additionally, BMD, elastic modulus (EM), and maximum compressive strength were determined. R2 for EM versus texture measures computed in the MR images was higher (R2 = 0.27-0.64, p < 0.01) in the spine than in the femur specimens (R2 = 0.12-0.22, p < 0.05). R2 values were similar in the CT images. R2 for EM versus BMD was 0.66 (p < 0.01) in the spine and 0.61 (p < 0.01) in the femur specimens. In the MR images, texture measures combined with BMD in a multivariate-regression model significantly increased R2, while improvement was less significant in the CT images. Thus, texture analysis may provide additional information needed to analyze bone strength and quality.

Adult↗

Trabecular bone mineral and calculated structure of human bone specimens scanned by peripheral quantitative computed tomography: relation to biomechanical properties.

The relationship of cortical bone mineral density (BMD), and geometry to bone strength has been well documented. In this study, we used peripheral quantitative computerized tomography (pQCT) to acquire trabecular BMD and high-resolution images of trabeculae from specimens to determine their relationship with biomechanical properties. Fifty-eight human cubic trabecular bone specimens, including 26 from the vertebral bodies, were scanned in water and air. Trabecular structure was quantitated using software developed with Advanced Visual Systems interfaced on a Sun/Sparc Workstation. BMD was also obtained using a whole-body computerized tomography scanner (QCT). Nondestructive testing of the specimens was performed to assess their elastic modulus. QCT and pQCT measurements of BMD of specimens in water were strongly correlated (r2 = 0.95, p < 0.0001), with a slope (0.96) statistically not significantly different from 1. Strong correlations were found between pQCT measurements of specimens in water and in air, for BMD (r2 = 0.96, p < 0.0001), and for apparent trabecular structural parameters (r2 = 0.89-0.93, p < 0.0001). Correlations were moderate between BMD and apparent trabecular structural parameters (r2 = 0.37-0.64, p < 0.0001). Precision as coefficient of variation (CV) and standardized coefficient of variation (SCV) for these measurements was < 5%. For the vertebral specimens, the correlation was higher between elastic modulus and BMD (r2 = 0.76,p < 0.0001) than between elastic modulus and apparent trabecular structural parameters (r2 = 0.58-0.72, p < 0.0001), while the addition of apparent trabecular nodes and branches to BMD in a multivariate regression model significantly increased the correlation with the elastic modulus (r2 = 0.86, p < 0.01). Thus, pQCT can comparably and reproducibly measure trabecular bone mineral in water or air, and trabecular structure can be quantitated from pQCT images. The combination of volumetric BMD with trabecular structural parameters rather than either alone improves the prediction of biomechanical properties. Such a noninvasive approach may be useful for the preclinical study of osteoporosis.

Adult↗

In vivo high resolution MRI of the calcaneus: differences in trabecular structure in osteoporosis patients.

The purpose of this study was to use high resolution (HR) magnetic resonance (MR) images of the calcaneus to investigate the trabecular structure of patients with and without osteoporotic hip fractures and to compare these techniques with bone mineral density (BMD) in differentiating fracture and nonfracture patients. Axial and sagittal HR MR images of the calcaneus were obtained in 50 female (23 postmenopausal patients with osteoporotic hip fractures and 27 postmenopausal controls). A three-dimensional gradient-echo sequence was used with a slice thickness of 500 micron and in plane resolution of 195 x 195 micron. Texture analysis was performed using morphological features, analogous to standard histomorphometry and fractal dimension. Additionally, BMd measurements of the hip (dual-energy X-ray absorptiometry) were obtained in all patients. Significant differences between both patient groups were obtained using morphological parameters and fractal dimension as well as hip BMD (p < 0.05). Odds ratios for the texture parameters apparent (app.) bone volume/total volume and app. trabecular separation were higher than for hip BMD. Receiver operator characteristic values of texture measures and hip BMD were comparable. In conclusion, trabecular structure measures derived from HR MR images of the calcaneus can differentiate between postmenopausal women with and without osteoporotic hip fractures.

Absorptiometry, Photon↗

Influence of size and stability of the osteotomy gap on the success of fracture healing.

Flexible fixation of fractures with minimally invasive surgical techniques has become increasingly popular. Such techniques can lead to relatively large fracture gaps (larger than 5 mm) and considerable interfragmentary movements (0.2-5 mm). We investigated the influence of the size of the fracture gap, interfragmentary movement, and interfragmentary strain on the quality of fracture healing. A simple diaphyseal long-bone fracture was modeled by means of a transverse osteotomy of the right metatarsus in sheep. In 42 sheep, the metatarsus was stabilized with a custom-made external ring fixator that was adjustable for gap size and axial interfragmentary movement. The sheep were randomly divided into six groups with three different gap sizes (1, 2, or 6 mm) and small or large interfragmentary strain (approximately 7 or 31%). The movement of the fracture gap was monitored telemetrically by a displacement transducer attached to the fixator. After 9 weeks of healing, the explanted metatarsus was evaluated mechanically in a three-point bending test to determine bending stiffness and was radiographed to measure the amount of periosteal callus formation. Increased size of the gap (from 1 to 6 mm) resulted in a significant reduction in the bending stiffness of the healed bones. Larger interfragmentary movements and strains (31 compared with 7%) stimulated larger callus formation for small gaps (1-2 mm) but not for larger gaps (approximately 6 mm). The treatment of simple diaphyseal fractures with flexible fixation can be improved by careful reduction of the fracture; this prevents large interfragmentary gaps. The experimental fracture model for the metatarsus showed that the healing process was inferior when the gap was larger than 2 mm.

Animals↗

Quantitative assessment of experimental fracture repair by peripheral computed tomography.

An experimental fracture model was used to assess bone mineral density at the fracture site by peripheral computed tomography and to compare the model with biomechanical, histological, and radiographic methods for the quantification of the fracture repair process. Transverse osteotomies in the mid-diaphysis of 28 tibia of sheep were externally fixed and mineral densities, cross-sectional areas, flexural rigidities, tissue composition, and projected callus area were calculated after 9 weeks of healing time. BMD measured by pQCT was strongly correlated with histologically determined percentages of mineralized tissue in the osteotomy gap (R = 0.71) and in the periosteal callus (R2 = 0.62). The percentage of mineralized tissue in the osteotomy gap was the best predictor of the flexural rigidity of the tibiae (R2 = 0.74). Because of high correlations with the histological findings, the volumetric BMD at the level of the osteotomy gap was also strongly correlated with the biomechanical findings (R2 = 0.70). Neither the cross-sectional area in pQCT nor the projected callus area in plane film radiography were positively correlated to the flexural rigidity of the tibiae. Quantitative computed tomography proved to be a successful estimator for the prediction of the mechanical stability of healing bones. The noninvasive procedure is a reliable tool for the quantification of the fracture repair process in experimental studies and may be useful for treatment decisions in particular clinical situations.

Animals↗

Patella position and biomechanical properties of the patellar tendon 1 year after removal of its central third.

OBJECTIVE: The aim of this study was to investigate how the removal of a patellar tendon graft for cruciate ligament reconstruction influences the mechanical properties of the remaining patellar tendon and the position of the patella at the knee joint. DESIGN: The experimental model of this in vivo study was the anterior cruciate ligament reconstruction in sheep. BACKGROUND: While the efficacy of a patellar tendon third as a ligament replacement has been extensively investigated, the consequences for the function of the remaining tendon and patella position remain unclear. METHODS: The central third of the patellar tendon from the right knees of 10 animals was removed for cruciate ligament replacement. One year postoperatively, the position of the patella within the joint and the stiffness and modulus of elasticity of the remaining tendon were compared with the non-operated contralateral controls. RESULTS: The patella position did not change in the operated knee joints in comparison with the controls. The cross-sectional area of the operated patellar tendon increased significantly by scar tissue formation at the defect site. CONCLUSION: Although the inferior mechanical properties of the scar tissue reduced the modulus of, elasticity of the tendon, the increase in cross-sectional area allowed it to develop a structural stiffness similar to the control tendons. RELEVANCE: The central third of the patellar tendon is often used for ligament replacement. Resulting biomechanical and structural changes in the remaining patellar tendon have not been previously reported using an in vivo animal model. The recovery of the biomechanical properties of the partially resected tendons allows for continued function.

Journal Article↗

Volumetric quantitative computed tomography of the proximal femur: precision and relation to bone strength.

We have developed a three-dimensional computed tomography (CT) scanning and image analysis method for measurement of trabecular and integral bone mineral density (BMD) and geometry in automatically determined femoral-neck and trochanteric subregions of the proximal femur. We measured the correlation of the density and geometry variables to femoral strength assessed in vitro under loading simulating a single-limb condition and a fall to the side. While BMD alone accounted for 48%-77% of the variability in strength for the stance loading configuration, femoral neck cross-sectional area (minCSA) and femoral neck axis length (FNAL) also contributed independently to femoral strength, and a combination of BMD and geometry variables explained 87%-93% of the variance in the data. For the fall loading configuration, trochanteric trabecular BMD alone explained 87% of the variability of strength. The reproducibility in vivo of the technique was assessed in a group of seven postmenopausal women, who underwent repeat scans with repositioning. For trabecular BMD, the precision was 1.1% and 0.6% for the femoral neck and trochanteric subregions, respectively, compared to 3.3% and 1.6% for the corresponding integral envelopes. Thus, trabecular BMD measurements were reproducible and highly correlated to biomechanical strength measurements. These results support further exploration of quantitative CT for assessment of osteoporosis at the proximal femur.

Accidental Falls↗

Prediction of fracture load at different skeletal sites by geometric properties of the cortical shell.

Quantitative bone assessment today is primarily based on the analysis of bone mineral density (BMD). The geometric properties of bone, which are an important parameter for skeletal strength, are generally not considered in the routine clinical assessment of osteoporosis. This study combined the geometric properties and the BMD values determined by peripheral quantitative computed tomography (pQCT) at the distal radius and at the femoral neck to predict fracture loads of the radius, femur, and lumbar vertebrae of 20 cadavers. Generalized osteopenia reduced the fracture loads at all three sites (p < 0.001). The strength of the radius and the femoral neck could best be predicted by considering either the second moment of inertia and trabecular BMD (R = 0.93) or the moment of inertia and the cortical BMD (R = 0.91). The geometric properties at the distal radius were highly correlated with the fracture load at the same skeletal site (R = 0.89) and were also used to estimate the fracture risk at the lumbar vertebrae (R = 0.75) and at the femoral neck (R = 0.87). We conclude that both geometry and density contribute substantially to the strength of the skeleton. The screening for osteoporosis and the prediction of fracture risk can be improved, therefore, by an additional consideration of the geometric properties of the cortex.

Aged↗

Calcaneal fractures cause a lateral load shift in Chopart joint contact stress and plantar pressure pattern in vitro.

In order to evaluate the effects of the anatomical changes after calcaneal fractures on joint loading characteristics we investigated the effects of simulated calcaneal fractures on intra-articular loading in the Chopart joint and on plantar pressure patterns in vitro. Five fresh-frozen lower leg specimens were axially loaded with 500 N in three positions: neutral, 10 degrees plantarflexion and 10 degrees dorsiflexion. The loading characteristics were determined before and after creating a tongue-type fracture by osteotomy. Plantar loading patterns were measured with a capacitive pressure distribution platform. Intra-articular contact areas and pressures were recorded on pressure sensitive film introduced into the talonavicular and calcaneocuboid joint. Increased loading in the calcaneocuboid joint (+25%,p = 0.005) and decreased loading in the talonavicular joint (-16%,p = 0.01) corresponded to increased loading of the lateral aspects of the plantar surface. These findings were independent of the foot position. The results suggest that the effects of increased lateral foot loading which have been observed in calcaneal fracture patients (Rosenbaum et al., Clin. Biomech. 10, 345-351, 1995) are caused by changes in joint kinematics and do not appear to result from a protective gait pattern established after the injury.

Adult↗

Early, full weightbearing with flexible fixation delays fracture healing.

Secondary fracture healing is known to be accelerated by the process of periosteal callus formation that can be induced by flexible fracture fixation in connection with loading of the injured extremity. The purpose of this study was to compare the healing of experimental fractures of long bones in sheep under early weightbearing with that of fractures under delayed, steadily increasing weightbearing. Differences in the quality of fracture healing were described by biomechanical (rigidity of fracture, indentation stiffness of callus) and histologic methods. Prevention from early, full weightbearing resulted in a higher flexural rigidity of the fracture, an increased mechanical stiffness of the callus tissue, and an enhanced bone formation at the healing front. Although early loading of a fresh fracture initiated an enormous amount of periosteal callus, the healing of the osteotomy was significantly delayed, and the quality of the newly formed tissue was reduced as compared with fractures with a reduced loading situation. A reduction of load transfer by delaying full weightbearing is advantageous for the healing of fractures stabilized with flexible fixation systems.

Animals↗

Increase of stability in external fracture fixation by hydroxyapatite-coated bone screws.

A major problem in fracture treatment by external fixation is screw loosening, which often results in reduced stability and can lead to prolonged treatment. A load-carrying experiment was conducted to determine whether coating implants with bioactive hydroxyapatite (HA) increases screw stability. Twelve HA-coated ASIF screws with 3 different macroporosities were inserted in 12 sheep that had already been fitted with a 6-pin external fixator for the treatment of a tibial osteotomy. The same number of uncoated polished steel screws served as controls. Although initial stability was not different for HA-coated screws, average removal torque after a 9-week implantation period increased with increasing macroporosity of the HA coating (p < .002). Instability of some screws was accompanied by histologic findings of cartilagenous tissue and proliferation of periosteal callus. Near the threads in the tibial cortex and in the shaft area of the screw were seen large numbers of HA particles that had been sheared off during implantation as well as during screw removal because of high contact forces between the HA coating and bone. Particulate debris of HA particles as well as the release of small bone fragments during explanation is likely to be unavoidable since HA adherence to bone is greater than adherence to steel after several weeks of implantation.

Animals↗

In vivo effect of shock-waves on the healing of fractured bone.

In a controlled animal experiment we attempted to clarify the question of whether there is a stimulating effect of extracorporeal shock-waves on the repair process of fractured long bones. As a fracture model we used an osteotomy in the diaphysis of the ovine tibia and an external fixation device. Shock-wave treatment at two levels of intensity and with four different numbers of applied shocks was performed with an electromagnetic acoustic source. Healing of the osteotomized bone was evaluated by biomechanical and radiological investigations on the whole bone as well as on bone sections from areas of the fracture gap and the periosteal fracture callus. We found a non-significant tendency to deterioration of the fracture healing with increasing shock-wave intensities. The study of treatment parameters led neither to significantly different biomechanical outcomes nor to altered radiological results in comparison to the untreated control group. RELEVANCE:--While we cannot comment upon the effectiveness of extracorporeal shock-waves in the delayed treatment of fractures or pseudarthrosis, our results suggest that shock-waves have no beneficial effect in acute fracture repair.

Journal Article↗

Effect of dynamization on gap healing of diaphyseal fractures under external fixation.

We asked whether dynamization of externally fixed diaphyseal fractures could improve bone healing in comparison to rigid fixation of fractures having similar remaining gap sizes. To answer this question we evaluated metatarsal osteotomies in 12 sheep. The osteotomy with a 0.6-mm gap was stabilized with a specially designed high bending and torsional stiffness external ring fixator. Osteotomies in six sheep were stabilized rigidly (axial movement < 0.06 mm) or dynamically (axial movement 0.15-0.34 mm). The cyclical axial interfragmentary movement was caused by the load-bearing of the operated limb. With increasing healing time, the initially allowed movement was decreased by callus formation around the osteotomy. The reduction in interfragmentary movement was measured and monitored by a linear variable displacement transducer at the external fixator and a telemetry system. After 9 weeks the sheep were sacrificed and the healed bones were investigated biomechanically and histomorphologically. Compared to the rigidly fixed osteotomies, the dynamized osteotomies showed significantly (P < 0.05) greater (+41%) callus formation and 45% greater tensile strength of the newly formed bone in the cortical osteotomy gap. Histological analysis indicated that the effect of dynamization occurred mainly after the 5th week. RELEVANCE: From these results we conclude that dynamic fixation of diaphyseal gaps is advantageous in comparison to stable external fixation.

Journal Article↗

Influence of water temperature on pressure pulses generated by an electromagnetic type lithotripter.

The need to survey and compare in vitro investigations on the effect of extracorporeally generated pressure pulses demands precise description of experimental conditions. We determined the effect of water temperature on the pressure characteristics in and around the focus area of an electromagnetic type lithotripter. The peak pressure amplitude at the geometrical focus of the lens was reduced to 60% of the original peak pressure if water at room temperature was used instead of water with human body temperature. By decreasing the temperature of the lithotripter's internal water, we observed shifting of the focus point at a rate of 1.4 mm per degree. This dramatic reduction of the peak pressure and the shifting of the focus point resulting from changes in the acoustic and thermal parameters of the propagation medium and of the focusing device could lead to differences of up to 80% of peak pressure amplitude.

Acoustics↗