Methemoglobinemia after topical anesthesia with lidocaine and benzocaine for a difficult intubation.

Methemoglobinemia is an uncommon cause of cyanosis; however, rapid diagnosis is critical to avoid potentially fatal consequences. Several local anesthetics can precipitate methemoglobinemia in susceptible patients. This case report of acute methemoglobinemia occurred during fiberoptic intubation in an awake patient without a past medical history of adverse reactions to local anesthetics.

Adult↗

The effect of nitroglycerin on the gravid uterus in sheep and rabbits.

UNLABELLED: Clinical reports suggest that nitroglycerin (TNG) has an effect on the uterus that is detected by the obstetrician on palpation, but not obvious by measurement of uterine pressure. This study was designed to compare the effects of TNG on uterine compliance and tension. We used three sets of experiments to evaluate the effect of TNG on the uterus. In vivo experiments were conducted on laboring ewes and rabbits 2 h postpartum to measure the effect of TNG on active uterine tension. An in vitro experiment was also conducted by using isolated uterine strips from term pregnant rabbits to evaluate the effect of TNG on uterine compliance. TNG had no discernible effect on uterine intracavitary pressure or frequency of contraction in either laboring ewes or postpartum rabbits at doses that were sufficient to reduce the mean arterial pressure. TNG did, however, increase the compliance of uterine tissue from rabbits at term, whereas S-nitroso-N-acetylpenicillamine failed to produce a similar effect. Thus, the perceived relaxant effects of TNG may be caused by an increase in uterine compliance, which may facilitate efforts by the obstetrician to manipulate the uterus. While the mechanism of action remains unclear, it appears to be independent of nitric oxide. IMPLICATIONS: The administration of nitroglycerin may have a relaxant effect on the uterus. These experiments were conducted to elucidate the effect of nitroglycerin on the peripartum uterus by measuring active tension and compliance.

Adrenergic beta-Agonists↗

Growth of Staphylococcus aureus in Diprivan and Intralipid: implications on the pathogenesis of infections.

BACKGROUND: The incidence and severity of infections are increased when Intralipid or Diprivan are administered to patients. Intralipid promotes infection, presumably by inhibiting the reticuloendothelial system, thereby suppressing the host's constitutive immunity, whereas Diprivan supposedly promotes infection by supporting bacterial growth and increasing the inoculating dose. This study considers whether bacterial replication alone in Intralipid and Diprivan adequately explains the increased risk of infection associated with these agents or whether other factors might also be involved. METHODS: Staphylococcus aureus was cultured in 10% Intralipid or Diprivan at clinically relevant conditions or in Intralipid containing 0.005% (w/v) sodium EDTA, a current additive, to measure growth. To determine whether Intralipid affected infection, New Zealand white rabbits were injected intravenously with S. aureus with or without Intralipid. Twenty-four hours later, bacteria in lung, liver, spleen, and kidney tissues were enumerated. RESULTS: S. aureus failed to grow in Diprivan or Intralipid containing 0.005% EDTA. Whereas S. aureus did replicate in plain Intralipid, growth was delayed until the bacteria conditioned the media. Once initiated, growth was slow at clinically relevant temperatures. The administration of Intralipid to rabbits significantly increased the recovery of staphylococci from the kidneys, P < 0.001, relative to the other tissues 24 h after an intravenous inoculation with S. aureus, compared with rabbits receiving S. aureus with no Intralipid. CONCLUSIONS: These results suggest that Diprivan, and possibly Intralipid, represent poor media for the growth of S. aureus and may promote infection through mechanisms other than increased inoculum size.

Anesthetics, Intravenous↗

Synchronization of radiograph film exposure with the inspiratory pause. Effect on the appearance of bedside chest radiographs in mechanically ventilated patients.

The appearance of portable chest radiographs (CXRs) may be affected by changes in ventilation, particularly when patients are mechanically ventilated. Synchronization of the CXR with the ventilatory cycle should limit the influence of respiratory variation on the appearance of the CXR. This study evaluates the effect of synchronizing the CXR film exposure with ventilation on the appearance of the radiograph. Twenty-five patients who remained intubated postoperatively, were mechanically ventilated, and required a CXR were enrolled in this triple-blind, randomized prospective study. Each patient received one radiograph using conventional techniques and another using the interface. The sequence of the two films was randomized, and the two films were taken on the same patient within a few minutes of each other. Hence, each patient served as his own control and the position of the patient, source-film distance, intensity (Kvp), and duration of the exposure (mAs) were identical for the two films. Five board-certified radiologists were then asked to compare paired films for clarity of lines and tubes, definition of the pulmonary vasculature, visibility of the mediastinum, definition of the diaphragm, and degree of lung inflation. Radiologists were also asked to choose which films they preferred. A majority of board certified radiologists preferred CXRs taken with the interface in 21 of 25 patients (p < 0.0001). Furthermore, four of the five criteria evaluated were improved (p < 0.05) on synchronized CXRs. Synchronization of the bedside CXR with the end of inspiration ensures that they are always obtained at maximal inflation, which improves the appearance of a majority of radiographs by at least one of five criteria.

Diaphragm↗

The potential for dissemination of Mycobacterium tuberculosis through the anesthesia breathing circuit.

BACKGROUND: Respiratory pathogens that pass through the anesthesia breathing system potentially can infect other patients. This study was designed to determine if bacteria can pass through contemporary anesthesia breathing systems and if the environment within the machine is hostile to these organisms. METHODS: Staphylococcus aureus, Pseudomonas aeruginosa, and Mycobacterium tuberculosis were nebulized into the expiratory limb of an anesthesia breathing circuit and collected from the inspiratory and expiratory limbs in an impinger system that provided a quantitative determination of the number of organisms entering the circuit and the number that would reach the patient in the inspiratory gas. Bacteria were collected before, during, and after nebulization. A second experiment determined if a saturated solution of soda lime was bactericidal. RESULTS: When the gas flow through the circuit was interrupted for < 1 h following the nebulization period, large numbers of microorganisms (1 x 10(3) to 1 x 10(5), around 100% of the nebulized organisms) were collected from the inspiratory gas. Soda lime itself was not bactericidal for any of the organisms tested, but solutions of this material with a pH of 12 were bactericidal. CONCLUSION: Cross contamination between patients may occur unless the gas flow through the anesthesia breathing system is interrupted for > 1 h.

Aerosols↗

A prospective study of the safety of tracheal extubation using a pediatric airway exchange catheter for patients with a known difficult airway.

STUDY OBJECTIVE: To determine the usefulness of routinely inserting a hollow airway exchange catheter (jet stylet) prior to tracheal extubation of adult patients with risk factors for difficult tracheal intubation. DESIGN: Prospective, 1-year study of 40 consecutive patients undergoing mechanical ventilation who had one or more risk factors for difficult tracheal reintubation. SETTING: Surgical ICU of a tertiary university medical center. INTERVENTIONS: Study patients at risk for difficult tracheal reintubation were extubated using a No. 11 Cook airway exchange catheter (CAEC). Following tracheal extubation, the CAEC was secured, and humidified oxygen was insufflated through the central lumen (2 to 8 L/min) for a minimum of 4 h, during which oxyhemoglobin saturation (SpO2) and respiratory frequency were monitored. Stridor or other signs of respiratory difficulty were also assessed. The CAEC was removed when it became clinically apparent that the need for tracheal reintubation was unlikely. When patients failed to respond to tracheal extubation, the CAEC was used to facilitate reintubation of these difficult airways. RESULTS: Respiratory distress necessitating tracheal reintubation occurred in 3 of 40 patients (8%). One patient failed to respond to tracheal extubation twice. None of the patients developed oxyhemoglobin desaturation (SpO2 <90%) before or during tracheal reintubation. All four reintubations were accomplished during the first attempt using the CAEC as a stylet. The CAEC was kept in the trachea for a mean duration of 9.4 h. There were no adverse events documented. CONCLUSIONS: The No. 11 CAEC is a useful and effective tool for giving patients a trial of extubation. Administration of oxygen through the CAEC diminishes the potential for hypoxia while maintaining the ability to reintubate the trachea, especially when reintubation might prove challenging. Previous data suggest that the CAEC is rigid enough to facilitate tracheal reintubation in adults; this was confirmed in the three patients in our study who required tracheal reintubation. The risk of aspiration, barotrauma, or other airway trauma during prolonged placement of the CAEC appears to be low (zero incidence in 40 patients in this study), and use of the No. 11 CAEC appeared to be safe. Since oxygen can be delivered through the CAEC, it may provide a means to safely evaluate an airway during a trial of extubation, ie, a reversible extubation. Finally, oxygen administration through the CAEC may obviate the need for facemask or nasal cannula following tracheal extubation.

Adolescent↗

Epidural catheter reconnection. Safe and unsafe practice.

BACKGROUND: An in vitro model of epidural catheter contamination was used to determine if disconnected catheters can be safely reconnected. METHODS: Epidural catheters were filled with brain-heart infusion (BHI) broth or preservative-free saline containing 5 micrograms/ml fentanyl. Escherichia coli, Pseudomonas aeruginosa, or Staphylococcus aureus (1.10(5) colony-forming units) was injected into the initial 1.1 +/- 0.24 inch (2.75 +/- 0.60 cm) of the catheters. To study the effect of bacteria settling in a vertically oriented catheter on the advancement of bacteria along the catheter, bacteria were incubated with catheters in the vertical and the horizontal positions. To determine if bacteria are swept further into a catheter when fluid in it is displaced, catheters were inclined 30 degrees and the fluid in them was allowed to drain from the distal end to various extents. Bacteria were incubated with the catheter held horizontally. After incubation, the catheters were serially sectioned, and the resulting segments were eluted with buffered saline-containing gelatin (BSG), which was collected on BHI agar plates for colony counts. This determined if a segment of the catheter remained internally sterile distal to the point of disconnection. Effectiveness of decontaminating the exterior of the catheter was also tested as follows: Catheters (n = 10) were first immersed in BSG containing 1.10(5) S, aureus, immediately immersed in betadine for 2 min, exposed to air for 3 min, cut with a sterile instrument, and reconnected to a sterile screw cap catheter connector. Reconnected catheters were perfused with 10 ml BSG for 1 hr. Collected perfusate (100 microliters) was removed for direct colony count; the remaining perfusate was mixed with an equal volume of BHI and incubated overnight. A 100 microliters aliquot of BHI-BSG mixture was sampled the next day. No bacteria were cultured from either the perfusate or BHI-BSG mixture. RESULTS: Eight hours after contamination, as long as the fluid in the catheter was static, no bacteria were detected more than 13 inches (32.5 cm) from the contaminated end of catheters filled with BHI and no more than 8 inches (20 cm) from the end of those filled with fentanyl solution. This finding was not affected by incubation of the catheter in the vertical position. Fluid displacement less than 8 inches (20 cm) had no effect on dissemination, but when fluid was displaced 13 inches (32.5 cm), bacteria were found at the end of the catheter, 35 inches (87.5 cm) away. No bacteria were recovered from the perfusate of reconnected catheters after the catheters were cleaned with betadine and cut with a sterile instrument. CONCLUSIONS: There may be an area distal to the disconnected end of an epidural catheter where its interior remains sterile for at least 8 hr. Such an area exists only when the fluid in the catheter remains static. Furthermore, the exterior of the catheter can be adequately cleaned to prevent bacteria from entering the catheter when reconnected at that point.

Analgesia, Epidural↗

Hyperresponsiveness of arterial rings induced by renal prehypertensive rabbit plasma.

Vascular rings from normal rabbit renal arteries, when bathed in processed plasma from 3-day renal artery stenosis (RAS) rabbits, had greater contractile responses to norepinephrine than did matched rings bathed in processed plasma from sham-operated rabbits. This vascular hyperresponsiveness of the rings produced by 3-day RAS plasma was abolished by the angiotensin II (ANG II) antagonist [Sar1, Ile8] ANG II but not by [Sar1, Ala8] ANG II at a dose that completely blocked the contractile responses of the rings to ANG II. The addition of [Sar1, Ala8]-ANG II to rings bathed in normal rabbit plasma did not alter the contractile responses to norepinephrine, indicating a lack of agonistic action by this ANG II analogue. These studies demonstrated that the ANG II receptors involved in the hormonally mediated vascular hyperresponsiveness in 3-day RAS rabbits are contained in the tissues that comprise these renal arterial rings.

1-Sarcosine-8-Isoleucine Angiotensin II↗