PubMed Health⌕ Search

Biomedical subjects

P B Sparks

Publications and source records attributed to P B Sparks.

At least 19 recordsLinked to original sources

Focal atrial tachycardia arising from the tricuspid annulus: electrophysiologic and electrocardiographic characteristics.

INTRODUCTION: Focal right atrial tachycardia (RAT) arising from the crista terminalis, para-Hisian, and coronary sinus os regions are well described. Less information exists regarding RAT arising from the nonseptal region of the tricuspid annulus (TA). METHODS AND RESULTS: From a consecutive series of 64 patients who had undergone successful radiofrequency ablation (RFA) of 67 RATs, the characteristics of 9 (13%) patients (6 men; mean age 50 +/- 20 years) with a TA focus were reviewed. The annular focus was localized to the inferoanterior TA in 7 and the superior TA in 2. Mean tachycardia cycle length was 371 +/- 66 msec. Mean activation time at the site of successful RFA in 9 of 9 patients was -43 +/- 11 msec. At 9.3 +/- 5.6 months of follow-up, 1 of 9 patients had recurrent tachycardia successfully treated with repeat RFA. In 7 of 9 patients with RAT from the inferoanterior TA, the surface ECG P wave morphology was upright in aVL, inverted in III and VI, and either inverted or biphasic with an initial negative deflection from V2 to V6. CONCLUSION: The TA is an important site of origin of RAT. In the present study, the inferoanterior region of the TA was a preferential site of origin with resulting characteristic P wave morphology. Knowledge of this anatomic distribution and P wave morphology allows targeted mapping and may facilitate successful RFA.

Adult↗

Clinical outcome after radiofrequency catheter ablation of focal atrial fibrillation triggers.

INTRODUCTION: Ablative therapy for atrial fibrillation (AF) by targeting initiating triggers, usually in or around the pulmonary veins, has been reported by several centers. Evidence for an overall improvement in quality of life (QOL) and amelioration of symptoms is lacking. METHODS AND RESULTS: Seventy-one patients undergoing attempted ablation of focal AF were followed for 60+/-33 weeks. QOL and symptom questionnaires were completed 1 month before and 6 months after electrophysiologic study. Twenty-three patients (32%) underwent electrophysiologic mapping but no ablation because of either insufficient or multifocal ectopy; the other 48 patients (68%) underwent attempted ablation. Sixteen of 48 patients (33%) undergoing ablation, or 16 (23%) of 71 on an intention-to-treat basis, were found at last follow-up to have persistent sinus rhythm without antiarrhythmic drugs. Patients who underwent mapping without ablation reported no improvements in any QOL or symptom score, whereas patients who had long-term successful ablation had significant improvements in all six QOL measures. Interestingly, patients who developed AF recurrence after ablation still reported significant improvements in 4 of 6 QOL measures. Four of 48 patients (8.3%) undergoing ablation developed pulmonary vein stenosis. CONCLUSION: Paroxysmal AF can be treated successfully in some patients by ablating initiating triggers in the pulmonary veins; however, in our experience the recurrence rate (32/48 [68%]) and risk of pulmonary vein stenosis (8%) after ablation are high. Patients with recurrent AF after ablation of focal AF triggers have significant improvement in QOL and symptoms compared with before ablation. Patients and their physicians should carefully balance the risks and benefits before considering ablation.

Adult↗

Electrical remodeling of the atria associated with paroxysmal and chronic atrial flutter.

BACKGROUND: Atrial electrical remodeling may be important for the initiation and perpetuation of atrial arrhythmias. Whether paroxysmal atrial flutter (AFL) and chronic AFL cause electrical remodeling of the atria has not been conclusively determined. METHODS AND RESULTS: Before radiofrequency ablation of paroxysmal AFL, 15 patients in sinus rhythm were evaluated under autonomic blockade. Lateral right atrial (LRA) effective refractory periods (ERPs) at 600 and 450 ms were measured before and at 1-minute intervals for 10 minutes after spontaneous or pace termination of a 5- to 10-minute period of induced AFL. In 10 patients with chronic AFL, LRA, septal, and coronary sinus (CS) ERPs and corrected sinus node recovery times (cSNRTs) at 600 and 450 ms were measured under autonomic blockade 15 minutes, 30 minutes, and 3 weeks after termination of chronic AFL by ablation. In the paroxysmal AFL group, LRA ERPs decreased by 18% at 600 ms and 12% at 450 ms (P:<0.01) after induced AFL and recovered to baseline over approximately 5 minutes. Atrial fibrillation developed during AFL in 3 patients and during ERP testing in 3 patients when refractoriness was at its nadir. In the chronic AFL group, LRA, septal, and CS ERPs at 3 weeks were significantly greater than at 15 and 30 minutes after termination of chronic AFL at both cycle lengths (P:<0.01). Three weeks after ablation, cSNRT decreased 35% at 600 ms (P:<0.05) and decreased 44% at 450 ms (P:<0. 05). Both ERPs and cSNRTs measured 15 and 30 minutes after ablation of chronic AFL were not significantly different. CONCLUSIONS: Both paroxysmal AFL and chronic AFL cause reversible electrical remodeling of the atria but demonstrate different time courses of recovery.

Aged↗

Dual demand pacing using retriggerable refractory periods for ventricular rate control during paroxysmal supraventricular tachyarrhythmias in patients with dual chamber pacemakers.

The use of dual chamber pacing in patients with atrioventricular block and paroxysmal supraventricular tachyarrhythmias may present a clinical dilemma because of the rapid and erratic triggering of ventricular pacing. To avoid this, a variety of pacing methods have now been described, including the use of retriggerable atrial refractory periods or dual demand pacing. This review details the use, advantages, and limitations of this poorly understood algorithm referred to as "pseudo-mode switching."

Algorithms↗

Electrical remodeling of the atria following loss of atrioventricular synchrony: a long-term study in humans.

BACKGROUND: Evidence suggests that an increased incidence of atrial fibrillation occurs in patients undergoing single-chamber ventricular pacing (VVI) when compared with those undergoing single-chamber atrial pacing (AAI) or those having dual-chamber atrioventricular pacing (DDD). The mechanism for this is unknown. We hypothesized that long-term loss of atrioventricular (AV) synchrony leads to atrial electrical remodeling: a potential explanation for this difference. METHODS AND RESULTS: The study was a prospective, randomized comparison between 18 patients paced in VVI mode and 12 patients paced in DDD mode for 3 months. Under autonomic blockade, effective refractory periods (ERPs) from the lateral right atrium (RA), RA appendage, RA septum, and coronary sinus-corrected sinus node recovery times (cSNRTs), as well as P-wave duration (PWD), and biatrial diameters were measured at baseline and 3 months. The VVI group was then programmed to DDD pacing and reevaluated after a further 3 months. After long-term VVI pacing, ERPs at all 4 atrial sites increased significantly in a nonuniform fashion in association with biatrial dilatation. PWD and cSNRTs also prolonged significantly. With the reestablishment of AV synchrony, ERPs, PWD, cSNRTs, and biatrial dimensions returned to baseline levels. In the 12 patients who underwent long-term DDD pacing from baseline, no significant changes in atrial electrophysiology or biatrial dimensions were demonstrated. CONCLUSIONS: Long-term loss of AV synchrony induced by VVI pacing is associated with atrial electrical remodeling, which is reversible after the reestablishment of AV synchrony with DDD pacing. This process may be partly responsible for the higher incidence of atrial fibrillation in patients undergoing VVI pacing compared with AV sequential pacing.

Aged↗

Mechanical remodeling of the left atrium after loss of atrioventricular synchrony. A long-term study in humans.

BACKGROUND: Tachycardia-mediated mechanical remodeling of the atrium is considered central to the pathogenesis of thromboembolism associated with chronic atrial fibrillation. Whether atrial mechanical remodeling also occurs in response to atrial stretch induced by chronic asynchronous ventricular pacing in patients with permanent pacemakers is unknown. METHODS AND RESULTS: The study design was a prospective randomized comparison between 21 patients paced chronically in the VVI mode and 11 patients paced chronically in the DDD mode for 3 months. Left atrial appendage (LAA) function and the presence of spontaneous echo contrast (SEC) were determined with transesophageal echocardiography (TEE) within 24 hours of pacemaker implantation and after 3 months. The VVI patients were then programmed to DDD and underwent a third TEE after DDD pacing for an additional 3 months. After chronic VVI pacing, LAA velocity decreased from 82.4+/-29.0 to 42.1+/-25.4 cm/s (P<0.01), LAA fractional area change decreased from 74.9+/-17.2% to 49.8+/-22.0% (P<0.01), and 4 patients (19%) developed left atrial SEC (P<0.05). With the reestablishment of chronic AV synchrony, LAA velocity increased to 61.6+/-18.5 cm/s (P<0.01), LAA fractional area change increased to 76.4+/-18.1% (P<0.01), and SEC resolved. In the 11 patients undergoing chronic DDD pacing, no significant changes in LAA velocity (baseline, 86.0+/-28.8 cm/s versus 3 months, 79.6+/-14. 9 cm/s) or LAA fractional area change (baseline, 76.2+/-19.4% versus 72.5+/-15.7%) were demonstrated, and SEC did not develop. CONCLUSIONS: Chronic loss of AV synchrony induced by VVI pacing is associated with mechanical remodeling of the left atrium, which may reverse after the reestablishment of AV synchrony with DDD pacing. This process may be partly responsible for the higher incidence of thromboembolism observed in patients undergoing VVI pacing compared with AV sequential pacing.

Aged↗

Left atrial mechanical function after brief duration atrial fibrillation.

OBJECTIVES: This study examined the effect of brief duration atrial fibrillation on left atrial and left atrial appendage mechanical function in humans with structural heart disease. BACKGROUND: Left atrial dysfunction and the development of spontaneous echo contrast (SEC) may follow the cardioversion of atrial fibrillation (AF) to sinus rhythm. This phenomenon has been termed "stunning" and is implicated in the development of atrial thrombus and embolic stroke. The effects of brief duration AF on left atrial mechanical function in humans are unknown. METHODS: Twenty-four patients (23 men, aged 59.1+/-12.7 years) with significant structural heart disease (ejection fraction 31.2+/-9.0%, left atrial diameter 4.9+/-0.4 cm) undergoing implantation of a ventricular cardiodefibrillator underwent transesophageal echocardiography to evaluate left atrial appendage emptying velocities (LAAeV) and SEC before, during and after a 15-min period of AF induced by rapid right atrial pacing. Atrial fibrillation was then permitted to terminate spontaneously within 5 min or was reverted with an endocardial direct current shock. Velocities and SEC were assessed in sinus rhythm pre-AF, during AF and immediately, 5 and 10 min after reversion to sinus rhythm. RESULTS: Atrial fibrillation terminated spontaneously in 10 patients after 16.1+/-1.0 min. Endocardial direct current (DC) cardioversion of 10.4+/-6.4 J was required in 14 patients after AF lasting 20 min. Mean LAAeV pre-AF (50.0 +/- 17.5 cm/s) was not significantly different to LAAeV immediately (52.8 +/- 16.7 cm/s), 5 min (54.3 +/- 16.4 cm/s) or 10 min (53.7 +/- 15.7 cm/s) after reversion to sinus rhythm. Atrial stunning defined as a reduction in LAAeV of >20% was not observed in any patient. Fourteen of 24 patients (58%) developed SEC during AF, which resolved within 30 s of AF termination. There were no significant differences between LAAeV in those patients reverting with DC shock (pre-AF 50.6+/-16.2 cm/s vs. immediately post-AF 54.7+/-16.6 cm/s) or in those patients with spontaneous reversion (pre-AF 48.9+/-20.2 cm/s vs. immediately post-AF 49.8+/-17.3 cm/s). CONCLUSIONS: Significant left atrial stunning was not observed after brief duration AF in humans with structural heart disease. Transient left atrial SEC develops in a significant proportion of these patients during AF but resolves rapidly on reversion to sinus rhythm. These findings suggest that the risk of thromboembolism may be low after brief duration AF that terminates either spontaneously or with an endocardial DC shock even in patients with significant structural heart disease. These findings have important implications for recipients of implantable devices that are capable of atrial defibrillation in response to AF.

Atrial Fibrillation↗

An anatomic approach to prevention of atrial fibrillation: pulmonary vein isolation with through-the-balloon ultrasound ablation (TTB-USA).

Our current understanding is that atrial fibrillation (AF) is initiated most often by a focal trigger from the orifice of or within one of the pulmonary veins. Though mapping and ablation of these triggers appears to be curative in most patients with paroxysmal AF, there are a number of limitations to ablating focal triggers via mapping and ablating the earliest site of activation with a "point" radiofrequency lesion. One way to circumvent thesen limitations is an anatomically-guided ablative approach. By electrically isolating one or more pulmonary veins from the left atrium with a circumferential lesion, firing from within those veins would be unable to reach the body of the atrium, and thus could not trigger atrial fibrillation. We have developed a novel over-the-wire catheter design which integrates a cylindrical ultrasound transducer within a saline filled balloon, termed TTB-USA (through-the-balloon ultrasound ablation) in order to produce narrow circumferential zones of hyperthermic tissue death at the pulmonary vein ostia. Animal studies show great promise, and clinical trials will begin soon.

Animals↗

Electrophysiologic effects of selective right versus left atrial linear lesions in a canine model of chronic atrial fibrillation.

INTRODUCTION: Long linear lesions have been shown to eliminate atrial fibrillation in animal models, but little is known about the electrophysiologic response in one atrium to lesions in the contralateral atrium. METHODS AND RESULTS: Twelve dogs with chronic atrial fibrillation were randomized to either right atrial ablation (n = 4), left atrial ablation first (n = 4), or a sham procedure (n = 4). Simultaneous biatrial endocardial mapping was performed before and after three linear lesions were applied at specific points in either atrium, using an expandable ablation catheter. Atrial fibrillation was reinducible after single atrial ablation in each dog and no longer inducible after biatrial ablation in five dogs. At baseline, the mean atrial fibrillation cycle length was longer on the trabeculated (117+/-15 msec) compared with the smooth right (101+/-16 msec) or left atrium (88+/-10 msec; P < 0.01). Single right and left atrial ablation caused a significant cycle length increase in the ablated atrium. Left atrial ablation increased the cycle length on both the trabeculated (121+/-18 msec vs 137+/-11 msec; P < 0.05) and smooth right atrium (108+/-12 msec vs 124+/-9 msec; P < 0.05). Right atrial ablation, however, had no significant effect on left atrial fibrillation cycle length (82+/-8 msec vs 86+/-7 msec). CONCLUSION: Left atrial linear lesions affect right atrial endocardial activation, whereas right atrial lesions do not affect left atrial activation in a canine model of atrial fibrillation. These findings suggest that the left atrium is the driver during chronic atrial fibrillation in this animal model and may explain the limited success of right atrial ablation alone in human atrial fibrillation.

Animals↗

Effect of direct current shocks on left atrial mechanical function in patients with structural heart disease.

OBJECTIVES: This study examined the effect of endocardial and transthoracic direct current (DC) shocks on left atrial and left atrial appendage function in humans with structural heart disease. BACKGROUND: DC cardioversion of atrial fibrillation (AF) to sinus rhythm is associated with transient left atrial and left atrial appendage dysfunction and the development of spontaneous echo contrast (SEC). This phenomenon has been termed atrial "stunning" and may be associated with thrombus formation and embolic stroke. To what extent the shock itself contributes to atrial stunning is unclear. METHODS: Thirteen patients in sinus rhythm undergoing implantation of a ventricular implantable cardioverter defibrillator (ICD) were prospectively evaluated. All patients had significant structural heart disease. To evaluate the effects of DC shocks on left atrial and left atrial appendage function, biphasic R wave synchronized endocardial shocks of 1, 10 and 20 J were delivered between the right ventricular electrode and the left pectoral generator of the ICD in sinus rhythm. R wave synchronized transthoracic shocks of 360 J were also delivered between anteriorly and posteriorly positioned chest electrodes. Transesophageal echocardiography was performed to evaluate left atrial appendage velocities, mitral inflow velocities and the presence of SEC before and immediately after each DC shock. RESULTS: There were no significant changes in left atrial or left atrial appendage function after endocardial or transthoracic DC shocks. Left atrial SEC did not develop after endocardial or transthoracic DC shocks. CONCLUSIONS: Endocardial and transthoracic DC shocks are not directly responsible for left atrial and left atrial appendage stunning and do not contribute to the stunning that is observed after the cardioversion of AF to sinus rhythm.

Aged↗

Left atrial "stunning" following radiofrequency catheter ablation of chronic atrial flutter.

OBJECTIVES: This study examined the effect of radiofrequency ablation (RFA) on left atrial (LA) and left atrial appendage (LAA) function in humans with chronic atrial flutter (AFL). BACKGROUND: Atrial stunning and the development of spontaneous echocardiographic contrast (SEC) is a consequence of electrical cardioversion of AFL to sinus rhythm. This phenomenon has been termed "stunning" and is associated with thrombus formation and embolic stroke. Radiofrequency ablation is now considered to be definitive treatment for chronic AFL, but whether this procedure is complicated by LA stunning is unknown. METHODS: Fifteen patients with chronic AFL undergoing curative RFA underwent transesophageal echocardiography to evaluate LA and LAA function and SEC before and immediately, 30 minutes and 3 weeks after RFA. To control for possible direct effects of RFA on atrial function, seven patients undergoing RFA for paroxysmal AFL were also studied. In this group, RF energy was delivered in sinus rhythm and echocardiographic parameters were assessed before and immediately and 30 minutes following RFA. RESULTS: Chronic AFL: Mean arrhythmia duration was 17.2 +/- 13.3 months. Twelve patients (80%) developed SEC following RF energy application and reversion to sinus rhythm. LAA velocities decreased significantly from 54.0 +/- 14.2 cm/s in AFL to 18.0 +/- 7.1 cm/s in sinus rhythm after arrhythmia termination (p < 0.01). These changes persisted for 30 minutes. Following 3 weeks of sustained sinus rhythm, significant improvements in LAA velocities (68.9 +/- 23.6 vs. 18.0 +/- 7.1 cm/s, p < 0.01) and mitral A-wave velocities (49.8 +/- 10.3 vs. 13.4 +/- 11.2 cm/s, p < 0.01) were evident and SEC had resolved in all patients. Paroxysmal AFL: Radiofrequency energy delivered in sinus rhythm had no significant effect on any of the above indexes of LA or LAA function and no patient developed SEC following RFA. CONCLUSIONS: Radiofrequency ablation of chronic AFL is associated with significant LA stunning and the development of SEC. Left atrial stunning is not secondary to the RF energy application itself. Sustained sinus rhythm for 3 weeks leads to resolution of these acute phenomena. Left atrial stunning occurs in the absence of direct current shock or antiarrhythmic drugs, suggesting that its mechanism may be a function of the preceding arrhythmia rather than the mode of reversion.

Atrial Flutter↗

Atrial fibrillation and anticoagulation in patients with permanent pacemakers: implications for stroke prevention.

Several large prospective randomized trials have demonstrated that anticoagulation with warfarin reduces the risk of thromboembolic stroke in high risk patients with chronic AF by approximately 70%. Large numbers of patients with permanent pacemakers have AF, and anticoagulation rates in this population have not been described. In a prospective analysis of 110 consecutive patients attending the pacemaker clinic of a large university hospital we assessed the number of patients with AF and the proportion of these patients who were receiving anticoagulation to prevent thromboembolic stroke. Where necessary, temporary pacemaker reprogramming to low ventricular rates was utilized to facilitate the diagnosis of AF. Fifty-three of the 110 patients (48%) were diagnosed with AF, all of whom (100%) had accepted high risk factors for thromboembolic stroke. Only eight of the 53 (15%) had been anticoagulated with warfarin. Thirty-six of the 53 patients (68%) diagnosed with AF had no prior documented diagnosis of chronic AF, and the majority had no symptoms suggesting AF. A single lead II ECG was insufficient in 67 of the 110 patients (61%) to diagnose the underlying atrial rhythm; the remainder required 12-lead ECGs or temporary pacemaker reprogramming to low ventricular rates to diagnose the underlying atrial rhythm. AF is common in patients with permanent pacemakers. It is commonly asymptomatic, and anticoagulation is markedly underutilized in reducing stroke risk in these patients. Attention to the possibility of AF in paced patients should allow prompt diagnosis and allow both the initiation of anticoagulation in order to reduce thromboembolic stroke risk and consideration for cardioversion of AF to sinus rhythm.

Aged↗

Radiofrequency ablation for cure of atrial flutter.

BACKGROUND: Atrial flutter is a common arrhythmia which frequently recurs after cardioversion and is relatively difficult to control with antiarrhythmic agents. AIMS: To evaluate the success rate, recurrence rate and safety of radiofrequency, (RF) ablation for atrial flutter in a consecutive series of patients with drug refractory chronic or paroxysmal forms of the arrhythmia. METHODS: Electrophysiologic evaluation of atrial flutter included activation mapping with a 20 electrode halo catheter placed around the tricuspid annulus and entrainment mapping from within the low right atrial isthmus. After confirmation of the arrhythmia mechanism with these techniques, an anatomic approach was used to create a linear lesion between the inferior tricuspid annulus and the eustachian ridge at the anterior margin of the inferior vena cava. In order to demonstrate successful ablation, mapping techniques were employed to show that bi-directional conduction block was present in the low right atrial isthmus. RESULTS: Successful ablation was achieved in 26/27 patients (96%). In one patient with a grossly enlarged right atrium, isthmus block could not be achieved. Of the 26 patients with successful ablation, there has been one recurrence of typical flutter (4%) during a mean follow-up period of 5.5 +/- 2.7 months. This patient underwent a successful repeat ablation procedure. Of eight patients with documented clinical atrial fibrillation (in addition to atrial flutter) prior to the procedure, five continued to have atrial fibrillation following the ablation. There were no procedural complications and all patients had normal AV conduction at the completion of the ablation. CONCLUSIONS: RF ablation is a highly effective and safe procedure for cure of atrial flutter. In patients with chronic or recurrent forms of atrial flutter RF ablation should be considered as a first line therapeutic option.

Adult↗

Inappropriate sinus tachycardia (IST): management by radiofrequency modification of sinus node.

BACKGROUND: Inappropriate sinus tachycardia (IST) is a rare form of supraventricular arrhythmia. It can cause disabling symptoms and may be refractory to medical treatment. In symptomatic drug refractory patients, sinus node excision or total ablation of the sinus node with permanent pacemaker implantation was the only therapeutic option. Recently, radiofrequency (RF) modification of the sinus node has been reported to be an effective treatment for this condition. AIM: To present our experience with sinus node modification using RF energy in the management of IST. METHODS: Between 1989 to 1996 three patients (two females and one male), aged 28-36 years were diagnosed with symptomatic IST. All had failed multiple drugs and hence underwent sinus node modification using RF. In the first two patients, the site of RF application was guided by anatomical landmarks using fluoroscopy to localise the presumed most superior portion of the crista terminalis and also the earliest site of atrial activation. In the third patient, a 20 pole electrode catheter was used to map the crista terminalis and guide the ablation. Success was defined by 20-30% reduction in the heart rate with normal atrial activation sequence after ablation. RESULTS: The three patients described here had IST by clinical, electrocardiographic and electrophysiological criteria and were refractory to multiple antiarrhythmic drugs. The number of RF applications were 11, 15, and three applied at the site of earliest atrial activation for the control of heart rates. Patient 3 had a early recurrence at one month and underwent repeat sinus node modification (five RF applications). All three patients who underwent RF modification of the sinus node had a successful outcome. The procedure was uncomplicated and the patients remain asymptomatic during follow up (20, 12 and three months) with satisfactory control of heart rate, although one patient requires atenolol which was previously ineffective. CONCLUSIONS: RF modification of the sinus node is feasible and effective for IST, and should be the treatment of choice in patients refractory to medical therapy.

Adult↗

The safety of digital mobile cellular telephones with minute ventilation rate adaptive pacemakers.

In vitro tests suggest that rate adaptive pacemakers using changes in transthoracic impedance to vary pacing rate may be affected by digital mobile telephones. Electromagnetic fields generated by digital mobile telephones (Global System for Mobile [GSM]) represent a potential source of electromagnetic interference (EMI) for the Telectronics META rate adaptive pacemakers, which use transthoracic impedance as a sensor to determine changes in minute ventilation. Sixteen implanted Telectronics META pulse generators were exposed to 25-W simulated GSM transmissions (900-MHz carrier pulsed at 2, 8, and 217 Hz with a pulse width of 0.6 ms) and the antenna of a 2-W digital mobile telephone (900-MHz, 217-Hz pulse, 0.6-ms pulse width). The 12 dual and four single chamber devices were programmed to maximum sensitivity and assessed in unipolar and bipolar settings and rate adaptive and nonrate adaptive modes. In all cases of EMI, testing was repeated at lower, more routinely set bipolar sensitivity levels. At maximum sensitivity, 11 of 16 devices displayed no evidence of EMI. Brief ventricular triggering occurred in 2, a brief pause in 1, a combination of both in 1, and a brief episode of pacemaker-mediated tachycardia in 1. With pulse generators programmed to more routine sensitivities, only one device displayed rare single beat ventricular triggering. No changes in minute ventilation rate adaptive pacing were observed. At maximum unipolar sensitivities, the META series of rate adaptive pacemakers are resistant to clinically important EMI from digital mobile telephones. Set at routine sensitivities, these devices perform reliably in the presence of digital mobile telephones.

Cardiography, Impedance↗

Immediate and long-term results of radiofrequency ablation of pulmonary vein ectopy for cure of paroxysmal atrial fibrillation using a focal approach.

BACKGROUND: Atrial fibrillation (AF) is frequently initiated by focal activity originating in the pulmonary veins. We present the early and long-term results of a focal approach to pulmonary-vein ablation for cure of paroxysmal AF. AIMS: The aim of this study was to establish the effectiveness of focal pulmonary vein radiofrequency ablation (RFA) for cure of paroxysmal AF. METHODS: Fifty-one consecutive patients (35 male; 45+/-11.4 years) were considered for RFA on the following criteria: (i) symptomatic drug refractory AF, (ii) high-density atrial ectopy, bursts of atrial tachycardia or AF, (iii) absence of structural heart disease and (iv) provision of informed consent. Pulmonary vein mapping and RFA were by single trans-septal puncture, which was only performed in patients with adequate focal activity at the time of procedure. Focal activity was present spontaneously or was elicited by isoprenaline, burst pacing or AF induction and cardioversion. RESULTS: One patient was excluded from the analysis due to non-pulmonary vein triggers. Trans-septal mapping and RFA were not performed in 22 patients (44%) due to: (i) inadequate ectopy (17), (ii) recurrent AF (1), (iii) inability to cross septum (2) and (iv) multiple foci (2). Of 28 patients, RFA was attempted with procedural success in 23 patients (82%), with no acute complications. Mean fluoroscopy time for patients having RFA was 29+/-11.5 mins. Pulmonary vein stenosis occurred in one case. Ten patients had symptomatic recurrence and, of those, two had further RFA. At a mean follow up of 11+/-8 months, 15 patients (54% ablated, 30% of the total cohort) remained free of AF without antiarrhythmics. CONCLUSION: This series highlights the low long-term success rate of RFA to cure AF by targeting pulmonary vein initiators using a focal approach. Electrical pulmonary vein isolation may provide better long-term results.

Atrial Fibrillation↗