Clinical diagnosis of pneumothorax is late: use of trend data and decision support might allow preclinical detection.

Pneumothorax in the newborn has a significant mortality and morbidity. Early diagnosis would be likely to improve the outlook. Forty-two consecutive cases of pneumothorax that developed after admission to a tertiary referral neonatal medical intensive care unit over 4 y from 1993 to 1996 were reviewed. The time of onset of the pneumothorax was determined by retrospective evaluation of the computerized trend of transcutaneous carbon dioxide (tcpCO2) and oxygen tensions. The timing of the occurrence in the notes and x-rays determined the time of clinical diagnosis noted at the time. The difference was the time the condition was undiagnosed. The overall mortality before discharge was 45% (19 cases), four patients succumbing within 2 h. The median time (range) between onset of pneumothorax and clinical diagnosis was 127 min (45-660 min). In most cases, the endotracheal tube was aspirated and the transcutaneous blood gas sensor was repositioned, and in at least 40% of the cases, the baby was reintubated before the diagnosis was made. Reference centiles were constructed for level of tcpCO2 and slope of the trended tcpCO2 over various time intervals (in minutes) from 729 infants from 23 to 42 wk gestation who needed intensive care during the first 7 d of life from the same time period. The 5-min tcpCO2 trend slopes were compared in index and matched control infants. The presence of five consecutive and overlapping 5-min slopes greater than the 90th centile showed good discrimination for a pneumothorax (area under the receiver operating characteristic curve, 89%). We concluded that 1) the clinical diagnosis of pneumothorax was late, occurring when infants decompensate; 2) trend monitoring of tcpCO2 might allow the diagnosis to be made earlier if used properly; and 3) use of reference centiles of the trended slopes of tcpCO2 might be used for automatic decision support in the future.

Carbon Dioxide↗

Temperature control in very low birthweight infants during first five days of life.

AIM: To determine ranges for skin temperatures in infants weighing under 1000 g in the first five days of life. METHOD: Abdominal skin and foot temperatures were automatically collected each second, averaged over 1 minute and stored on computer. A computer program analysed the data in 83 babies weighing under 1000 g at birth over the first five days of life and expressed the temperatures as means and standard deviation. The temperature patterns seen in these babies were also visually analysed. The relation between an increasing abdominal skin-foot temperature difference and other signs of hypovolaemia was also studied. RESULTS: These babies all had similar temperature patterns. Just after birth there was little ability to vasoconstrict in the presence of cold stress and the babies behaved more like poikilothermic animals. Vasomotor tone developed in the first three days, resulting in a stabilisation of the abdominal skin temperature to a mean of 36.9 degrees C and a widening of the central-peripheral temperature difference (Td) to a mean of 1.0 degree C. A Td of > 2 degrees C was associated with other evidence of hypovolaemia for only 11% of the time. CONCLUSIONS: Infants weighing under 1000 g have poor vasomotor control at birth and are at increased risk from cold stress. After the first two to three days of life, monitoring the central-peripheral temperature difference gives an early indication of cold stress.

Abdomen↗

The murine homolog of the human breast and ovarian cancer susceptibility gene Brca1 maps to mouse chromosome 11D.

The recently cloned human breast and ovarian cancer susceptibility gene, BRCA1, is located on human chromosome 17q21. We have isolated murine genomic clones containing Brca1 as a first step in generating a mouse model for the loss of BRCA1 function. A mouse genomic library was screened using probes corresponding to exon 11 of the human BRCA1 gene. Two overlapping mouse clones were identified that hybridized to human BRCA1 exons 9-12. Sequence analysis of 1.4 kb of the region of these clones corresponding to part of human exon 11 revealed 72% nucleic acid identity but only 50% amino acid identity with the human gene. The longest of the mouse Brca1 genomic clones maps to chromosome 11D, as determined by two-color fluorescence in situ hybridization. The synteny to human chromosome 17 was confirmed by cohybridization with the mouse probe for the NF1-gene. This comparative study confirms that the relative location of the BRCA1 gene has been conserved between mice and humans.

Amino Acid Sequence↗

Data exchange in metrology.

The adoption of the directives 71/316/EEC on measuring instruments and 90/384/EEC on non-automatic weighing instruments has resulted in a considerable quantity of certificates to be exchanged between the Central Metrological Authorities and the Local Metrological Authorities, in the member states. This requirement to exchange data, prompted the setting up of the WELMEC working group, to explore how computerisation could help the member states perform their tasks.

Computer Systems↗

The place of routine urine testing on admission to hospital.

An audit of routine urine testing by dipsticks at a large private provincial hospital analysed 2294 patient records. No result was recorded in 12% of records. Abnormal but expected results were obtained in 9% of cases. Of the 4% of unexpectedly abnormal results, in only one-third of patients was the attending practitioner aware of these results and, in fewer than one-fifth of the patients, were further diagnostic tests performed. In not one case was treatment altered.