PubMed Health⌕ Search

Biomedical subjects

P Bednarz

Publications and source records attributed to P Bednarz.

5 recordsLinked to original sources

Bisphosphonate treatment affects trabecular bone apparent modulus through micro-architecture rather than matrix properties.

Bisphosphonates are emerging as an important treatment for osteoporosis. But whether the reduced fracture risk associated with bisphosphonate treatment is due to increased bone mass, improved trabecular architecture and/or increased secondary mineralization of the calcified matrix remains unclear. We examined the effects of bisphosphonates on both the trabecular architecture and matrix properties of canine trabecular bone. Thirty-six beagles were divided into a control group and two treatment groups, one receiving risedronate and the other alendronate at 5-6 times the clinical dose for osteoporosis treatment. After one year, the dogs were killed, and samples from the first lumbar vertebrae were examined using a combination of micro-computed tomography, finite element modeling, and mechanical testing. By combining these methods, we examined the treatment effects on the calcified matrix and trabecular architecture independently. Conventional histomorphometry and microdamage data were obtained from the second and third lumbar vertebrae of the same dogs [Bone 28 (2001) 524]. Bisphosphonate treatment resulted in an increased apparent Young's modulus, decreased bone turnover, increased calcified matrix density, and increased microdamage. We could not detect any change in the effective Young's modulus of the calcified matrix in the bisphosphonate treated groups. The observed increase in apparent Young's modulus was due to increased bone mass and altered trabecular architecture rather than changes in the calcified matrix modulus. We hypothesize that the expected increase in the Young's modulus of the calcified matrix due to the increased calcified matrix density was counteracted by the accumulation of microdamage.

Alendronate↗

Contact stresses in the glenoid component in total shoulder arthroplasty.

Several studies of retrieved glenoid components from total shoulder arthroplasty show an erosion of the rim, surface irregularities, component fracture and wear resulting from polyethylene deformation in vivo. Particles resulting from polyethylene wear might be one of the reasons for the very high rate of glenoid component loosening found clinically. Because wear can be the result of high contact stresses, the aim of this study is to find out whether or not contact stresses are high enough to cause wear of the glenoid component and what influence the component type and geometry have on polyethylene contact stresses for different humerus abduction angles. Elasticity theory is used in a parametric study of contact stresses in several glenoid component designs. A finite element method is used to confirm the accuracy of the analytical solution. The analysis shows that the peak stress generated in glenoid components under conditions of normal living can be as high as 25 MPa; since this exceeds the polyethylene yield strength, wear and also cold flow of the components can be expected. It is predicted that more conforming components have lower contact stresses, which might result in lower wear rate and less cold flow. It is also found that a metal-backed component promotes higher contact stresses than an all-polyethylene component with the same total thickness, therefore it can be expected that metal-backed components have inferior wear properties.

Arthroplasty, Replacement↗

Yield of vancomycin-resistant enterococci and multidrug-resistant Enterobacteriaceae from stools submitted for Clostridium difficile testing compared to results from a focused surveillance program.

It has been suggested that a method of performing surveillance for vancomycin-resistant enterococci (VRE) is to screen specimens submitted for Clostridium difficile testing. We compared this approach to our focused surveillance program of high-risk units during October 1997 to compare the yield of VRE and multidrug-resistant Enterobacteriaceae (MDRE) with both methods. Of the stools submitted for C. difficile testing, 14% were positive for VRE or MDRE, whereas rectal swabs from routine surveillance yielded 11% VRE- or MDRE-positive results. Although stools submitted for C. difficile testing resulted in a higher percentage of positive cultures, 14 VRE- and 2 MDRE-positive patients from our high-risk population were missed because many patients had no stool submitted for C. difficile testing. Therefore, while screening stools submitted for C. difficile testing cannot replace our focused surveillance program, it appears advantageous to assess these stools at various intervals to detect new patient reservoirs of drug-resistant organisms that may benefit from routine surveillance cultures.

Clostridioides difficile↗

Mechanical properties of brain tissue in-vivo: experiment and computer simulation.

Realistic computer simulation of neurosurgical procedures requires incorporation of the mechanical properties of brain tissue in the mathematical model. Possible applications of computer simulation of neurosurgery include non-rigid registration, virtual reality training and operation planning systems and robotic devices to perform minimally invasive brain surgery. A number of constitutive models of brain tissue, both single-phase and bi-phasic, have been proposed in recent years. The major deficiency of most of them, however, is the fact that they were identified using experimental data obtained in vitro and there is no certainty whether they can be applied in the realistic in vivo setting. In this paper we attempt to show that previously proposed by us hyper-viscoelastic constitutive model of brain tissue can be applied to simulating surgical procedures. An in vivo indentation experiment is described. The force-displacement curve for the loading speed typical for surgical procedures is concave upward containing no linear portion from which a meaningful elastic modulus might be determined. In order to properly analyse experimental data, a three-dimensional, non-linear finite element model of the brain was developed. Magnetic resonance imaging techniques were used to obtain geometric information needed for the model. The shape of the force-displacement curve obtained using the numerical solution was very similar to the experimental one. The predicted forces were about 31% lower than those recorded during the experiment. Having in mind that the coefficients in the model had been identified based on experimental data obtained in vitro, and large variability of mechanical properties of biological tissues, such agreement can be considered as very good. By appropriately increasing material parameters describing instantaneous stiffness of the tissue one is able, without changing the structure of the model, to reproduce experimental curve almost perfectly. Numerical studies showed also that the linear, viscoelastic model of brain tissue is not appropriate for the modelling brain tissue deformation even for moderate strains.

Animals↗

Persistent contamination of fabric-covered furniture by vancomycin-resistant enterococci: implications for upholstery selection in hospitals.

Vancomycin-resistant enterococci (VRE) have emerged as important nosocomial pathogens in hospitals throughout the United States. An increasing concern with respect to VRE dissemination is survival on, and potential transmission from, environmental surfaces within health care institutions. Therefore, we assessed survival of VRE on fabric chairs in an attempt to determine the optimal upholstery for the health care setting. VRE was identified on 3 of 10 seat cushions sampled, including 2 chairs in a room of a patient with known VRE. After performing simulated contamination experiments, all samples were positive at 72 hours and 1 week after inoculation. Contamination of the upholstery could be prevented by placing a sheet folded 4 times or a bath blanket folded in half on the seat cushion. In conclusion, VRE are capable of prolonged survival on fabric seat cushions and can be transferred to hands. Environmental surfaces such as chairs may serve as a potential reservoir for nosocomial transmission of VRE, and an easily cleanable, nonporous material is the preferred upholstery in hospitals.

Chicago↗