PubMed Health⌕ Search

Biomedical subjects

P Bisgaard

Publications and source records attributed to P Bisgaard.

3 recordsLinked to original sources

The Mt. Hood challenge: cross-testing two diabetes simulation models.

Starting from identical patients with type 2 diabetes, we compared the 20-year predictions of two computer simulation models, a 1998 version of the IMIB model and version 2.17 of the Global Diabetes Model (GDM). Primary measures of outcome were 20-year cumulative rates of: survival, first (incident) acute myocardial infarction (AMI), first stroke, proliferative diabetic retinopathy (PDR), macro-albuminuria (gross proteinuria, or GPR), and amputation. Standardized test patients were newly diagnosed males aged 45 or 75, with high and low levels of glycated hemoglobin (HbA(1c)), systolic blood pressure (SBP), and serum lipids. Both models generated realistic results and appropriate responses to changes in risk factors. Compared with the GDM, the IMIB model predicted much higher rates of mortality and AMI, and fewer strokes. These differences can be explained by differences in model architecture (Markov vs. microsimulation), different evidence bases for cardiovascular prediction (Framingham Heart Study cohort vs. Kaiser Permanente patients), and isolated versus interdependent prediction of cardiovascular events. Compared with IMIB, GDM predicted much higher lifetime costs, because of lower mortality and the use of a different costing method. It is feasible to cross-validate and explicate dissimilar diabetes simulation models using standardized patients. The wide differences in the model results that we observed demonstrate the need for cross-validation. We propose to hold a second 'Mt Hood Challenge' in 2001 and invite all diabetes modelers to attend.

Albuminuria↗

A method for personal sampling and analysis of nanogram amounts of formaldehyde in air.

An air sampling and analytical system for formaldehyde measurements based on a solid sampler is described. The samplers were tested on a standard atmosphere in the range of 0.2 to 0.8 mg/m3 dry air. A single 340 mg sorbant section had without drying sections a capacity of 16 micrograms formaldehyde in dry air and 3 micrograms at 70% RH, 23 degrees C. The precision of fluorimetric analysis was better than 6% for samples of 300, 600 and 1200 ng formaldehyde, and the accuracy was better than 10%. The precision of a colorimetric analysis was 12% for a 300 ng sample and 2% for 600 and 1200 ng samples. The accuracy of this method was better than 7%. Both the fluorimetric and the colorimetric analyses are found to be accurate and sensitive analytical methods for the determination of low formaldehyde concentrations. However, if measurements of more than 15 minutes duration are taken and a dessicant is used, the accuracy still remains to be verified. Positive interference from acrolein (5-7% interference when equimolar amounts are present) was found, but there was no interference from other aldehydes.

Air Pollutants, Occupational↗