PubMed Health⌕ Search

Biomedical subjects

P Boccacci

Publications and source records attributed to P Boccacci.

4 recordsLinked to original sources

Super-resolution in computational imaging.

Super-resolution is a word used in different contexts but mainly in the case of methods aimed at improving the resolution of an optical instrument beyond the diffraction limit. Such a result may be achieved by means of specific instrumental techniques (such as, for instance, interferometry) or by means of a suitable processing of a digital image; in the latter case we will use the expression computational super-resolution (CSR). In this paper we describe the basic concepts underlying CSR without using the mathematics required for establishing its theoretical validity. The aim is to introduce a wide audience to this topic, to specify the situations where CSR is feasible and to emphasize the point that unlimited CSR is not possible.

Algorithms↗

Experimental validation of a linear model for data reduction in chirp-pulse microwave CT.

Chirp-pulse microwave computerized tomography (CP-MCT) is an imaging modality developed at the Department of Biocybernetics, University of Niigata (Niigata, Japan), which intends to reduce the microwave-tomography problem to an X-ray-like situation. We have recently shown that data acquisition in CP-MCT can be described in terms of a linear model derived from scattering theory. In this paper, we validate this model by showing that the theoretically computed response function is in good agreement with the one obtained from a regularized multiple deconvolution of three data sets measured with the prototype of CP-MCT. Furthermore, the reliability of the model as far as image restoration in concerned, is tested in the case of space-invariant conditions by considering the reconstruction of simple on-axis cylindrical phantoms.

Computer Simulation↗

Image restoration in chirp-pulse microwave CT (CP-MCT).

Chirp-pulse microwave computed tomography (CP-MCT) is a technique for imaging the distribution of temperature variations inside biological tissues. Even if resolution and contrast are adequate to this purpose, a further improvement of image quality is desirable. In this paper, we discuss the blur of CP-MCT images and we propose a method for estimating the corresponding point spread function (PSF). To this purpose we use both a measured and a computed projection of a cylindrical phantom. We find a good agreement between the two cases. Finally the estimated PSF is used for deconvolving data corresponding to various kinds of cylindrical phantoms. We use an iterative nonlinear deconvolution method which assures nonnegative solutions and we demonstrate the improvement of image quality which can be obtained in such a way.

Algorithms↗