Fusion in medical imaging: theory, interests and industrial applications.

The accumulation of several data coming from medical images and signals, expert knowledge and databases is becoming very common for the study of a given pathology. The aggregation of all this information is mentally performed by a clinician, and generally allows for a better medical decision in clinical studies. We propose in this article a fusion method that models this aggregation process. This method is a three step scheme, that first transforms all the available information in a common theoretical frame, then aggregates these data using their redundancy and their conflicts, and finally computes a new information synthesizing all the initial knowledge. We first introduce in this article the fusion scheme and its theoretical aspects, and we particularly focus on the three steps of the process. We then detail the software implementation of this concept, achieved in collaboration with SEGAMI Corporation Inc. We finally apply this concept to a real clinical problem, the study of Alzheimer's disease using MR and SPECT images, and we show very encouraging preliminary results.

Aged↗

Iterative reconstruction methods for nonuniform attenuation distribution in SPECT.

Two iterative methods, a generalization of the Chang method and a projection precorrection, were investigated to determine whether the use of an attenuation map could improve nonuniform attenuation compensation. After a detailed description of the methods, results obtained with simulated and phantom data were compared. This study demonstrates that projection precorrection provides accurate quantification and good image quality as early as the precorrection step, whereas the generalized Chang method requires computation of one more iteration.

Algorithms↗

The value of pixel per pixel multiharmonic Fourier analysis to assess left ventricular function.

Left ventricular systolic and diastolic function can be assessed by peak ejection and filling rates and their time of occurrence. These parameters can be calculated using two different methods: from the global left ventricular time-activity curve analysed with a four harmonic Fourier fit and from each pixel time-activity curve analysed with two and three harmonics (the values being averaged over the left ventricular region of interest). In both cases, values were normalized for heart rate and end diastolic counts. A study was conducted in a series of 11 patients (six without and five with a previous myocardial infarction but a normal left ventricular function) examined at baseline and during an i.v. dobutamine infusion, at a dose known to increase both peak ejection and filling rates. During dobutamine infusion, analysis of global left ventricular time-activity curve demonstrated a statistically significant increase in both peak ejection and filling rates, but the local analysis showed a more significant increase of these parameters. To assess ventricular function, a local harmonic analysis can be used and appears to be a more sensitive approach than analysis of the global left ventricular time-activity curve. The local analysis provides spatial mapping and a histogram of the parameters which can be used as parametric images to describe systolic and diastolic function.

Dobutamine↗

Filters and Fourier analysis of gated blood pool studies: a search for the optimal combination.

Fourier analysis of gated blood pool studies is performed after filtering the raw data by a spatial median 3 x 3, 9 x 9 or temporo-spatial 9 x 9 x 9 filter. 20 patients and a dynamic cardiac phantom were studied to determine the quantitative effects of these filters and of multiharmonic Fourier filtering (MHFF). The filtered MHFF data, with or without preprocessing, were compared with a 3 D or 2 D filter to the raw data using a chi 2 distribution. The MHFF (two or three harmonics) procedure applied to the raw data of patients without any preprocessing produced the smallest chi 2 value, thus demonstrating the very close relationship between filtered images and raw data. Preprocessing the raw data by the median filter also preserved the signal when two or three harmonics were applied, whereas the 3 D and 2 D (9 x 9) filters did not. The phantom study also demonstrated that MHFF preserved the signal better than any other preprocessing. The median filter introduced a smaller distortion than the 2 D (9 x 9) and 3 D filters. It is concluded that MHFF applied with two or three harmonics on the raw data or after preprocessing by a median (3 x 3) filter is the most successful way of preserving the real signal. It is believed that the other filters should be avoided. The clinical advantage of MHFF processing is to provide both very accurate filtering and parametric images.

Fourier Analysis↗

Improved detection of anterior left ventricular aneurysm with multiharmonic fourier analysis.

Single and multiharmonic Fourier analysis of LAO 30-45 degrees gated blood-pool studies were performed in a selected group of 30 patients with a left ventricular anterior aneurysm proven by contrast angiography. The sensitivity of the first harmonic phase image for the diagnosis of ventricular aneurysm was 80%. The clear phase shift (greater than 110 degrees) between the normal and the aneurysmal areas was missing in six patients. Peak acceleration images (negative maximum of the second derivative of the Fourier series) were calculated for each pixel with the analytical Fourier formula using two or three harmonics. A clear phase shift (greater than 126 degrees) than appeared in all the patients. This improvement was related to the increased weight of the second and third harmonics in the aneurysmal area when compared to control patients or to patients with dilative cardiomyopathy. Multiharmonic Fourier analysis clearly improved the sensitivity of the diagnosis of anterior left ventricular aneurysm on LAO 30 degrees-45 degrees gated blood-pool images.

Cardiomyopathy, Dilated↗