PubMed HealthSearch

Biomedical subjects

P C Fong

Publications and source records attributed to P C Fong.

15 recordsLinked to original sources

Percutaneous transluminal coronary angioplasty in a patient with paroxysmal nocturnal hemoglobinuria.

Paroxysmal nocturnal hemoglobinuria (PHN) is an acquired chronic hemolytic anemia associated with an unusual susceptibility to hemolytic crisis, infection, and venous thrombosis which would be aggravated by a number of factors including surgery. We report a case of PHN undergoing percutaneous transluminal coronary angioplasty and discuss the corresponding perioperative management.

Adult

Ventricular rate-adaptive pacing in the elderly.

The role of ventricular rate-adaptive pacing (VVIR) in the elderly was investigated in 12 patients with a mean age of 85 +/- 2 years (range 75-95 years) with implanted activity-initiated VVIR pacemakers. Although four patients had significant extracardiac diseases, all were capable of independent walking and self care. The pacing rate achieved during structured daily activities (walking, climbing stairs, washing, bed-making and scrubbing floors) were compared with those achieved by 10 age-matched healthy subjects. Apart from the more strenuous activities (ascending stairs and floor-scrubbing), the pacing rates achieved by the patients were comparable to those of the healthy subjects and occurred within an appropriate time. In a 4-weekly randomized, double-blind crossover protocol in the VVI and VVIR pacing modes, all patients underwent assessments in a 12-min walking distance test, a 24 h non-invasive ambulatory blood pressure recording and a symptomatic documentation. During VVIR pacing, the 12-min walking distance was significantly improved compared to VVI pacing (556 +/- 52 vs. 545 +/- 55 m, P less than 0.05). There was no difference between the recorded blood pressure and symptom scores between the two pacing modes, although most patients preferred VVIR pacing (P less than 0.05). It is concluded that VVIR pacing in this elderly population can improve exercise capacity, and the patients' preference for the VVIR mode was documented despite the absence of a measurable difference in symptomatology.

Aged

The use of implantable sensors for the control of pacemaker mediated tachycardias: a comparative evaluation between minute ventilation sensing and acceleration sensing dual chamber rate adaptive pacemakers.

The role of implantable sensors to control pacemaker mediated tachycardias was investigated in 16 patients with two different dual chamber rate adaptive (DDDR) pacemakers, which sensed eiter minute ventilation (DDDR-Meta, nine patients) or body acceleration (Relay, seven patients). Successive atrial sensed events beyond a programmable rate occurring in the absence of detection of exercise by the sensors were considered to represent retrograde conduction or atrial arrhythmias, and the pacemakers responded by either a mode shift from DDDR to ventricular rate adaptive (VVIR) pacing (DDDR-Meta) or by tracking at an interim rate, the so-called conditional ventricular tracking limit (CVTL, Relay). In the unipolar atrial sensing mode, myopotential sensing (MPI) and external chest wall stimulations (CWS) at 250 beats/min were induced to be preferentially sensed by the atrial channel to simulate the conditions of atrial arrhythmias. In the DDD mode, these maneuvers resulted in ventricular responses of 88 +/- 3 beats/min and 110 +/- 3 beats/min for MPI and CWS, respectively. The pacing rate was significantly reduced in the DDDR mode with the sensors correctly detecting and responding to the sensed abnormal atrial signals (68 +/- 5 beats/min during MPI and 71 +/- 5 beats/min during CWS, P less than 0.005 compared with the corresponding DDD rate). One patient with a Relay pacemaker developed spontaneous atrial flutter and the ventricular tracking responses were 140 and 85 beats/min in the DDD and DDDR pacing modes, respectively. Thus MPI and CWS are useful bedside testing methods to assess pacemaker response during atrial arrhythmias. The use of implantable sensors to judge the appropriateness of atrial rate is a new approach to the management of pacemaker mediated tachycardias.

Adult

Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers.

Although a long postventricular atrial refractory period (PVARP) may prevent the occurrence of pacemaker mediated tachycardias and inadvertent tracking of atrial arrhythmias in dual chamber (DDD) pacing, the maximum upper rate will necessarily be compromised. We tested the feasibility of using minute ventilation sensing in a dual chamber rate adaptive pacemaker (DDDR) to shorten the PVARP during exercise in 13 patients with bradycardias (resting PVARP = 463 +/- 29 msec) to avoid premature upper rate behavior. Graded treadmill exercise tests in the DDD and DDDR modes at this PVARP resulted in maximum ventricular rates of 98 +/- 8 and 142 +/- 3 beats/min, respectively (P < 0.0001), due to chronotropic incompetence and upper rate limitation in the DDD mode, both circumvened with the use of sensor. In order to stimulate atrial arrhythmias, chest wall stimulation was applied for 30 seconds at a rate of 250 beats/min at a mean unipolar atrial sensitivity of 0.82 mV. Irregular ventricular responses occurred in the DDD mode (the rates at a PVARP of 280 and 463 +/- 29 msec were, respectively 92 +/- 5 and 66 +/- 3 msec; P < 0.0001). In the DDDR mode at a PVARP of 463 +/- 29 msec, regular ventricular pacing at 53 +/- 2 beats/min occurred due to mode switching to VVIR mode in the presence of repetitive sensed atrial events within the PVARP. One patient developed spontaneous atrial fibrillation on follow-up, which was correctly identified by the pacemaker algorithm, resulting in mode switch from DDDR to regular VVIR pacing and preservation of rate response. In conclusion, sensor controlled PVARP allows a long PVARP to be used at rest without limiting the maximum rate during exercise. In addition, to offer protection against retrograde conduction, a long PVARP and mode switching also limit the rate during atrial arrhythmias and allow regular ventricular rate responses according to the physiological demands.

Aged

Clinical experience with an activity sensing DDDR pacemaker using an accelerometer sensor.

The rate adaptive characteristics and pacemaker mediated tachycardia protection algorithm of an accelerometer based DDDR pacemaker were evaluated in 11 patients with bradycardia (seven atrioventricular block, four sick sinus syndrome). Rate adaptive programming was effected by collecting the acceleration level during a 3-minute moderate exercise ("tailoring" of sensor). In comparison with an externally attached piezoelectric sensor, the accelerometer sensor showed lower rate changes during external tapping of the pacemaker (16 +/- 3 vs 29 +/- 4 ppm, P less than 0.02) and applied direct pressure (1 +/- 1 vs 40 +/- 3 beats/min, P less than 0.001) on the pacemaker. At nominal setting, the accelerometer sensor showed improved rate stability and higher rate response to jogging and standing, although responses to other daily activities and treadmill exercise were similar. Apart from changing the rate responsive slope, rate response could be improved by repeat "tailoring" of the sensor at a lower exercise level, resulting in better overall rate response characteristics. The ability of the rate monitoring software to collect acceleration levels for an activity and profile the projected rate response at different rate responsive settings allowed programming to be effected with the minimum amount of exercise testing. The pacemaker also discriminated atrial tachyarrhythmias from normal sinus response using the sensor to judge the appropriateness of the atrial rate, which correctly identified and prevented rapid ventricular tracking in two patients during atrial flutter/fibrillation.

Adult

Bidirectional tachycardia induced by herbal aconite poisoning.

This report details the clinical, electrocardiographic, and electropharmacological characteristics of an unusual case of bidirectional tachycardia induced by aconites present in a Chinese herbal decoction consumed by a previously healthy subject. The tachycardia showed marked susceptibility to vagotonic maneuvers, cholinesterase inhibition, and adenosine triphosphate. The incessant nature of the tachycardia, rapid recurrence after transient suppression, and failure to respond to direct current cardioversion suggested an automatic tachycardia mechanism consistent with known data on the cellular electrophysiological mechanism of aconitine-mediated arrhythmogenesis. A fascicular or ventricular myocardial origin of the tachycardia with alternating activation patterns, or dual foci with alternate discharge, appeared most plausible. The rootstocks of aconitum plants have been commonly employed in traditional Chinese herbal recipes for "cardiotonic" actions and for relieving "rheumatism." Multiple pitfalls could occur during the processing of these herbs that might have predisposed to aconite poisoning. The need for strict control and surveillance of herbal substances with low margins of safety is highlighted.

Aconitum

Incessant automatic ventricular tachycardia complicating acute coxsackie B myocarditis.

A 13-year-old girl presented with incessant ventricular tachycardia complicating acute Coxsackie B3 myocarditis. Electrophysiologic assessment revealed that the tachycardia could not be terminated, overdrive suppressed or accelerated by programmed electrical stimulation, but was transiently slowed by intravenous adenosine triphosphate and had marked spontaneous and sympathoautonomic-mediated fluctuation in the tachycardia cycle length. These features were atypical of reentry and triggered automaticity and suggested that abnormal automaticity was the likely tachycardia mechanism. Intravenous amiodarone slowed the ventricular tachycardia, but the patient eventually succumbed from rapidly progressive left ventricular failure. Postmortem pathohistologic examination confirmed the diagnosis of acute myocarditis.

Adolescent

Bilateral coronary-artery-to-pulmonary-artery fistula coexistent with apical hypertrophic cardiomyopathy--a case report.

A sixty-four-year-old man presented with repolarization abnormalities on the electrocardiogram. Echocardiography and cardiac catheterization revealed that he had the rare combination of apical hypertrophic cardiomyopathy with bilateral coronary-artery-to-pulmonary-artery fistula. An exercise thallium scan was negative, suggesting that the marked electrocardiographic changes were most likely secondary to the apical myocardial hypertrophy, instead of to coronary-steal-induced ischemia.

Arterio-Arterial Fistula

Cerebral haemorrhage in anticoagulated patients with non-septic mechanical valvular prosthesis.

Cerebral haemorrhage in anticoagulated patients with mechanical valvular prosthesis poses an uncommon but difficult management problem. Four such patients are presented: one patient had delayed haemorrhagic transformation of a preexisting cerebral infarct, one probably had de novo haemorrhage complicating hypertension and in two patients cerebral haemorrhage was associated with excessive anticoagulation. Conservative management including the use of fresh frozen plasma, delayed heparinisation and warfarinisation was used. Both patients with anticoagulant overdose died as a result of extensive haemorrhage despite the drainage of cerebellar haematoma in one patient. The remaining two patients survived with minimal neurological deficits. Diagnosis of the underlying cause of cerebral haemorrhage, and the timing of heparinisation and anticoagulation are discussed.

Adult

Diffuse aortitis complicating Behçet's disease leading to severe aortic regurgitation.

Cardiovascular complications are uncommon in Behçet's disease, but are frequently the cause of morbidity and mortality. Venous and peripheral arterial involvement have been well documented, but involvement of the proximal aorta has rarely been described. This report details a Chinese patient with Behçet's disease. Diffuse aortitis led to proximal aortic dilatation and severe aortic regurgitation necessitating aortic valve replacement. Histopathology of the aorta revealed features similar to those observed in other systemic diseases with aortic involvement.

Adult

Propylthiouracil hypersensitivity with circumstantial evidence for drug-induced reversible sensorineural deafness: a case report.

Severe adverse reactions to propylthiouracil occur in 1-5% of patients. Three major side effects, namely agranulocytosis, hepatotoxicity and drug-induced hypersensitivity, have been described though these syndromes are not distinct entities and there can be overlaps in the clinical manifestations. The drug-induced hypersensitivity may be an immune-mediated reaction with multiorgan involvement in which a combination of polyarthritis, cutaneous vasculitis and fever is common. We report a patient with propylthiouracil-induced hypersensitivity with an unusual combination of high spiking fever, migratory polyarthritis, reversible sensorineural deafness, normochromic normocytic anaemia, leucocytosis and hepatotoxicity associated with polyclonal activation of multiple autoantibodies. This case illustrates the highly variable clinical manifestations of the syndrome. The prompt recovery upon withdrawal of the drug indicates the importance of early diagnosis.

Adult

Reentrant fascicular tachycardia with cycle length alternans: insights into the tachycardia mechanism and origin.

This report details the electrophysiology of a unique case of reentrant fascicular tachycardia in a patient without structural heart disease. Persistent cycle length alternans, with constant fluctuation in alternate RR intervals, occurred during tachycardia. A distinct mode of spontaneous termination of tachycardia was observed. The findings were consistent with the presence of decremental conduction properties in the tachycardia circuit or decremental dual functional pathways within one limb of the circuit. These observations provide further evidence in support of a fascicular origin of the tachycardia.

Bundle of His

Pacemaker mediated tachycardias in single chamber rate responsive pacing.

Although pacemaker mediated tachycardias are classically associated with dual chamber pacemakers, single chamber rate responsive pacemakers are also susceptible to such tachycardias under special circumstances. A unipolar activity sensing rate responsive pacemaker (Activitrax 8403) was implanted in an 83-year-old man with complete atrioventricular block. The pacemaker was programmed at an output of 5 V, activity threshold medium, rate response 5, and lower and upper rates of 70 and 125 beats/min, respectively. He presented with palpitations at rest and muscle twitching of the pacemaker pocket 4 months after implantation. Examination confirmed that the pacemaker had flipped over, resulting in pocket pacing which in turn activated the activity sensor, resulting in a rate response. The increase in pacing rate lead to a higher frequency of pocket pacing, thus leading to positive feedback increase in rate. With the patient at rest, pacemaker mediated rates were 106, 91, and 74 beats/min at low, medium and high thresholds, respectively. Decreasing the output to 2.5 V eliminated pocket pacing and the tachycardia. As a result of the reversal of the pacemaker, a similar rate response during exercise could only be achieved at a more sensitive rate responsive setting. Thus, pacemaker mediated tachycardia can complicate pacemaker "flipping" in single chamber activity sensing rate responsive pacemakers. Methods for the avoidance and treatment of pacemaker flipping are discussed. A review of other sensor mediated tachycardias is also presented.

Aged