Publications and source records attributed to P C Li.

At least 19 recordsLinked to original sources

Industrial wideband noise reduction for hearing aids using a headset with adaptive-feedback active noise cancellation.

High-intensity noises are a health hazard for industrial workers, and hearing protection is necessary to prevent hearing loss. Passive methods, such as ear muffs, are ineffective against low-frequency noise. Moreover, many hearing-impaired workers must wear hearing aids to enable communication at their workplace, and such aids can amplify ambient noise. To overcome this problem, the present study developed a headset equipped with a digital signal processing system to implement adaptive-feedback active noise cancellation (AFANC) to reduce low-frequency noise. The proposed AFANC headset was effective against wideband industrial noise, with a maximum noise spectrum power reduction of 30 dB. Furthermore, when used with a hearing aid, it improved the speech signal-to-noise ratio by up to 14 dB. These results suggest that a headset with AFANC would be useful for hearing protection in workplaces with high levels of low-frequency industrial noise, especially for hearing-impaired workers.

Ear Protective Devices↗

Optoacoustic imaging with synthetic aperture focusing and coherence weighting.

Optoacoustic imaging takes advantage of high optical contrast and low acoustic scattering and has found several biomedical applications. In the common backward mode a laser beam illuminates the image object, and an acoustic transducer located on the same side as the laser beam detects the optoacoustic signal produced by thermoelastic effects. A cross-sectional image is formed by laterally scanning the laser beam and the transducer. Although the laser beam width is generally narrow to provide good lateral resolution, strong optical scattering in tissue broadens the optical illumination pattern and thus degrades the lateral resolution. To solve this problem, a combination of the synthetic aperture focusing technique with coherence weighting is proposed. This method synthesizes a large aperture by summing properly delayed signals received at different positions. The focusing quality is further improved by using the signal coherence as an image quality index. A phantom comprising hair threads in a 1% milk solution was imaged with an optoacoustic imaging system. The results show that the proposed technique improved lateral resolution by 400-800% and the signal-to-noise ratio by 7-23 dB over conventional techniques.

Acoustics↗

Left ventricular cavity-to-myocardium count ratio in exercise and resting technetium-99m-tetrofosmin SPECT: correlation with left ventricular function.

The aim of this study was to assess the value of the cavity-to-myocardium count ratio (C/M ratio) calculated in exercise and resting technetium-99m (Tc-99m) tetrofosmin single photon emission computed tomography (SPECT) images to identify patients with depressed exercise and resting left ventricular ejection fraction (LVEF). We studied 60 patients with recent coronary artery diseases (CAD) undergoing first-pass ventriculography to calculate LVEF and myocardial perfusion SPECT imaging to calculate left ventricular C/M ratios. The group A of 30 CAD patients with higher LVEF (> or = 40%) had significant higher C/M ratios than the group B of 30 CAD patients with abnormal LVEF (< 40%) during exercise and rest. However, C/M ratios between exercise and rest did not differ significantly in the both groups A and B. There is significant correlation between exercise/rest LVEF and exercise/rest C/M ratios. Tc-99m tetrofosmin C/M ratios calculated SPECT perfusion images are useful parameters in identifying patients with depressed LVEF in CAD patients.

Adult↗

Neurophysiological effects of recurrent laryngeal and thoracic vagus nerves on mediating the neurogenic inflammation of the trachea, bronchi, and esophagus of rats.

The present study aims to investigate the neurophysiological effects of recurrent laryngeal nerve and thoracic vagus nerve on the non-cholinergic regulation of neurogenic plasma extravasation of the rat trachea, bronchi, and esophagus. Through thoracotomy, three nerve components, the right thoracic vagal trunk, thoracic vagus nerve, and recurrent laryngeal nerve, were identified. The experiment was sequentially conducted in four steps. First, the individual nerve component was electrically stimulated and the induced inflammatory responses, as quantified by the area density of India ink-labelled blood vessels in the trachea, bronchial trees and esophagus, were compared. Second, we assessed the relative importance of medial and lateral side of the right thoracic vagus nerve in inducing the inflammatory responses by alternative stimulation of one side with simultaneous severance of the other side of this nerve. Third, we examined the effects of transection of the lateral half of the right thoracic vagus nerve on the degeneration of axon fibers located at the following three sites: the nerve segment proximal to cutting site, bronchial and esophageal nerve branches. Finally, we directly observed the inflammatory histopathology of the right lower trachea after stimulation of the medial half of the right thoracic vagus nerve with transection of its lateral half. In this study, we found that the right recurrent laryngeal nerve was predominant in mediating the neurogenic inflammatory responses of upper and dorsal portions of trachea, whereas the right thoracic vagus nerve was predominant in mediating those of the right lower ventral wall of trachea, right main bronchus, and right lobar bronchial trees. The axon fibers of the right thoracic vagus nerve responsible for mediating the neurogenic inflammatory responses of the right lower ventral trachea were mainly accumulated in the medial half, whereas those innervating the right main bronchus, right lobar bronchial trees, and lower esophagus were largely in the lateral half of this nerve. Transection of the lateral half of the right thoracic vagus nerve resulted in significant degeneration of myelinated fibers in its bronchial and esophageal nerve branches. Histopathological examination of the right lower trachea after electrical stimulation of the medial half of thoracic vagus nerve demonstrated the silver-stained leaky venules with accumulations of inflammatory cells. We thus concluded that afferent C-fibers to upper and dorsal portions of trachea were mainly from recurrent laryngeal nerve. In contrast, the neurogenic inflammatory responses of the right lower trachea were predominantly mediated by the medial half of the right thoracic vagus nerve, and those of the right main bronchus, bronchial trees and lower esophagus were largely by the lateral half of this nerve.

Animals↗

Elastic properties of tendon measured by two different approaches.

Elastic properties of tendon were assessed by two different approaches. Six fresh bovine Achilles tendon specimens were used. The first approach directly measured Young's modulus along the transverse direction (E(perpendicular)) and the longitudinal direction (E(parallel)), using a cyclic compression-relaxation method. Young's moduli were derived based on the measured strain and stress values. The ratio of E(parallel): E(perpendicular) at smaller strains was around 4 and decreased to 0.6 approximately 1.1 at larger strains. The second approach assumed that tendons are transversely isotropic. Three observable second-order elastic stiffness constants (c(11), c(13) and c(33)) were obtained by sound speed measurements along various propagation directions. The measured elastic stiffness constants were also correlated with results from the first approach. It was shown that the transverse isotropy assumption was valid at small strains. However, a significant discrepancy existed between the two approaches. The discrepancy was primarily due to viscoelasticity associated with the first approach.

Achilles Tendon↗

Strain compounding: spatial resolution and performance on human images.

Compounding has long been used to reduce speckle brightness variations by incoherently combining partially correlated measurements of the same image object. Conventionally, decorrelation between measurements is introduced by imaging from different spatial positions (i.e., spatial compounding) or within different frequency ranges (i.e., frequency compounding). An alternative compounding approach based on speckle decorrelation of an object under different strain conditions was recently proposed. The new approach was referred to as strain compounding. Speckle correlation of strain compounding was previously analyzed using simulations and radiofrequency (RF) data from a gelatin-based phantom. Results indicated that effective speckle reduction is possible at strains potentially achievable in certain clinical situations. In this paper, performance of strain compounding is further analyzed. Potential degradation in spatial resolution of strain compounding is compared to that of conventional approaches using computer simulations. Results show that strain compounding potentially can achieve the same level of speckle reduction, with less degradation in spatial resolution if a large compression can be applied. Performance of strain compounding is also tested using postdetection human images acquired by a commercial imaging system. Two-dimensional (2-D) speckle tracking is performed to correct for tissue motion resulting from external compression and to ensure that the images to be compounded are spatially matched. Thyroid images show that speckle brightness variations can be effectively reduced without significant degradation in spatial resolution. Speckle reduction in liver imaging is also demonstrated. However, speckle reduction is not as significant as in thyroid imaging, due to the fact that a large compression cannot be achieved.

Humans↗

A capillary zone electrophoretic method for the study of formation of a covalent conjugate between microcystin LR and protein phosphatase 2A.

The study of conjugate formation between microcystin (MCYST)-LR and protein phosphatase (PP) 2A, which was isolated from bovine kidney and mouse brain, was achieved by using a highly efficient capillary zone electrophoretic (CZE) separation method. The MCYST-LR-PP2A conjugate (from bovine kidney) was resolved from its precursor after just 15 min of incubation. Moreover, the migration time, and, hence, the total analysis time, was less than 5 min. While the present findings of the time lag between conjugate formation and full inhibition are not novel, the CZE method does provide an alternative tool to HPLC with a higher separation efficiency to yield data for kinetic and mechanistic studies of the enzyme-toxin interaction. The CZE data reported here were found not to be adequately described by a first-order kinetic model. Moreover, the CZE method, which involves the use of a low ionic strength aqueous buffer, does not suffer from the drawback of the use of denaturing organic solvents such as those used in HPLC.

Animals↗

Harmonic leakage and image quality degradation in tissue harmonic imaging.

Image quality degradation caused by harmonic leakage was studied for finite amplitude distortion-based harmonic imaging. Various sources of harmonic leakage, including transmit waveform, signal bandwidth, and system nonlinearity, were investigated using both simulations and hydrophone measurements. Effects of harmonic leakage in the presence of sound velocity inhomogeneities were also considered. Results indicated that sidelobe levels of the harmonic beam pattern were directly affected by harmonic leakage when the harmonic signal was obtained by filtering out the fundamental signal. Because sidelobe levels also increase with the bandwidth of the transmitted signal, a trade-off exists between axial resolution and contrast resolution. It is concluded that accurate control of the frequency content of the waveform prior to propagation is necessary to optimize imaging performance of tissue harmonic imaging. The filtering technique was also compared with the pulse inversion technique. It was shown that the pulse inversion technique effectively suppresses harmonic leakage at the cost of imaging frame rate and potential motion artifacts.

Computer Simulation↗

On velocity estimation using speckle decorrelation.

Quantitative estimation of blood velocity using Doppler techniques is fundamentally limited because only the axial component can be detected. Speckle decorrelation resulting from scatterer motion may be used to compute non-axial components and to obtain quantitative flow information. Based on both simulations and experimental results, it is shown that the decorrelation technique is feasible only for constant flows. If flow gradients are present, the correlation between two signals along the same line of observation may be significantly affected by the gradients. Therefore, the decorrelation method cannot be used for quantitative flow estimation if flow gradients are not accurately measured and effects on signal correlation are not fully compensated. Results in this paper show that accurate estimation of flow gradients is practically difficult. It is further shown that effects of signal-to-noise ratio (SNR) on the correlation must also be taken into account for quantitative flow analysis.

Biomedical Engineering↗

Tissue harmonic image analysis based on spatial covariance.

The van Cittert-Zernike theorem has been widely used to describe spatial covariance of the pressure field backscattered from a speckle object. Spatial covariance contains important information in the context of correlation-based correction of sound velocity inhomogeneities. Previous work was primarily based on spatial covariance analysis for linear imaging. In this paper, we extend the analysis to tissue harmonic imaging. Specifically, we investigate effects of the signal-to-noise ratio (SNR) and sound velocity inhomogeneities on spatial covariance. Results from tissue harmonic imaging are also compared with those from linear imaging. Both simulations and experiments are performed. At high SNRs, although both linear imaging and tissue harmonic imaging have spatial covariance functions close to theory, the spatial covariance of tissue harmonic imaging is consistently lower than that of linear imaging regardless of the presence of sound velocity inhomogeneities. At low SNRs, on the other hand, spatial covariance of tissue harmonic imaging is significantly affected. Because the tissue harmonic signal is much weaker than the linear counterpart, the low SNR reduces the accuracy of correlation-based estimation. It is concluded that the linear signal is more suitable for correlation-based correction of sound velocity inhomogeneities, despite the fact that tissue harmonic imaging generally has improved image quality over linear imaging.

Ultrasonography↗

Filter-based synthetic transmit and receive focusing.

Most diagnostic ultrasonic imaging systems perform fixed focusing on transmit and dynamic focusing on receive. Such systems suffer from image quality degradation at depths away from the transmit focal zone. Several dynamic transmit focusing techniques have been previously investigated. Among them, a filter-based, retrospective focusing technique was proposed to increase the length of the transmit focal zone. In this paper, the filter-based technique is extended from dynamic receive focusing to fixed receive focusing. It is shown that the filtering technique with fixed receive focusing can achieve an image quality similar to that of dynamic receive focusing with filtering. The performance of the proposed approach is verified using real ultrasound data. It is shown that the proposed approach with fixed receive focusing requires a longer filter than that with dynamic receive focusing. Nonetheless, system complexity is greatly reduced with synthetic transmit and receive focusing because the dynamic receive focusing circuit is no longer needed.

Algorithms↗

Feasibility study of time-intensity-based blood flow measurements using deconvolution.

Ultrasonic contrast agents have been used to enhance the acoustic backscattered intensity of blood and to assist the assessment of blood flow parameters. One example is the time-intensity method based on the indicator-dilution theory. In this case, a mixing chamber model can be employed to describe the concentration of the contrast agent as a function of time. By measuring the time intensities at both the input and output of the blood mixing chamber, blood flow information can be obtained if proper deconvolution techniques are applied. Note that most deconvolution techniques assume a linear and time invariant (LTI) system for the mixing of the contrast agent with blood. In this paper, the hypothesis that a blood mixing chamber is an LTI system was tested. Several aspects were studied. One aspect was the linear relationship between the concentration of the contrast agent and the backscattered intensity. The other aspect was the dependence of the derived time constants on the concentration. The concept of an effective mixing volume was also introduced and evaluated. Finally, the input and the output time constants were measured and compared to theory under the LTI assumption. Extensive experiments were performed. Two in vitro flow models were constructed and two contrast agents were used. Results indicated that the LTI assumption does not hold and quantitative flow estimation is generally not possible. Nonetheless, the indicator-dilution theory can still be applied if only relative measurements of the flow rate are required.

Contrast Media↗

Universal antenatal human immunodeficiency virus testing in Hong Kong: consensus statement.

Following the recommendations of the Advisory Council on AIDS, Hong Kong, the Hospital Authority announced plans to introduce universal antenatal screening for human immunodeficiency virus infection and hence, a consensus conference was held to discuss strategies for implementing such screening in Hong Kong. This paper reports the discussions of the consensus conference. The consensus meeting group consisted of 15 clinicians and scientists from Hong Kong, Macau, and Thailand. Seven commonly asked questions concerning mother-to-child transmission of human immunodeficiency virus were selected for discussion by the participating panellists. Information on the laboratory diagnosis of human immunodeficiency virus infection and the efficacy of preventive measures in reducing mother-to-child transmission of human immunodeficiency virus were reviewed. Data from local studies was also presented and discussed. The timing, potential problems, and cost issues involved in testing all pregnant women in Hong Kong for human immunodeficiency virus were then considered.

Adult↗

Micellar electrokinetic capillary chromatographic separation and fluorescent detection of amino acids derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole.

Another method has been developed for the separation of amino acids (1 min derivatization plus 22 min separation) by micellar electrokinetic capillary chromatography (MECC) with laser-induced fluorescence detection. Interestingly enough, such work has never been performed on essential amino acids derivatized by 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). Fifteen L-amino acid standards were labelled with NBD-F at 60 degrees C for 1 min, and separated in a buffer system containing 20 mM borate, 25 mM sodium cholate, 10 mM Brij 35 and 2.5% methanol. Methanol was employed to expand the MECC migration time window; whereas Brij 35 was used to improve the fluorescence intensity of amino acid derivatives. This method also indicates that bile salt is effective for MECC separation of ionic analytes. Surprising though, improvements in resolution, sensitivity and speed for amino acids analysis are obtained in this work, which are not initially apparent in just employing another derivatizing reagent. Under optimal conditions, 15 amino acids were separated in a short 22 min analysis time, the shortest ever reported, and detection limits of nanomolar concentration and attomole mass were obtained. Furthermore, RSDs of migration time and peak height are better than 1% and 1.8%, respectively, again the smallest ever reported in the literature.

4-Chloro-7-nitrobenzofurazan↗

Antioxidant activity of phenylethanoid glycosides from Brandisia hancei.

Brandisia hancei is a medicinal herb in China. The ethanol extract of this plant and four phenylethanoid glycosides, acteoside (1), 2'-acetylacteoside (2), poliumoside (3) and brandioside (4), isolated from it were shown to have inhibitory effects on free radical-induced hemolysis of red blood cells and free radical scavenging activities in vitro. Brandioside (4) and poliumoside (3) showed stronger antioxidant effect than acteoside (1), 2'-acetylacteoside (2) and trolox.

Animals↗

Successful application of extracorporeal membrane oxygenation and intra-aortic balloon counterpulsation as lifesaving therapy for a patient with amniotic fluid embolism.

A woman in labor was noted to have amniotic fluid embolism. Extracorporeal membrane oxygenation and intra-aortic balloon counterpulsation were performed post partum, and the vital signs became stable. The ensuing recovery was uneventful. We conclude that extracorporeal membrane oxygenation and intra-aortic balloon counterpulsation should be considered to save the life of a patient with amniotic fluid embolism and left ventricular failure unresponsive to medical therapy.

Adult↗

A dynamic focusing technique for delta-sigma-based beamformers.

Beamformation using oversampling delta-sigma (deltasigma) modulators has been proposed for diagnostic ultrasound. Such a beamformer can reduce the size, complexity and cost of an imaging system while providing adequate signal-to-quantization noise ratio (SQNR). High quality images can also be generated if dynamic receive delays are applied correctly. Several dynamic focusing techniques were previously proposed. Generally, an additional bit or extra compensation circuit is required to preserve the power and frequency distribution of the signal. Without preserving the power and frequency distribution, the image background noise is increased. In this paper, an alternative technique is presented. The new technique exploits the symmetry of focusing delays relative to the center of a transducer array. By properly synchronizing the delays and selecting the inserted values, no noise is added to the beam sum signal and the image background level is not increased. Using real ultrasound data, it is shown that the proposed technique provides the same imaging performance as the previous approaches with reduced system complexity by using only a single bit to encode the output of the deltasigma modulator.

Electronics, Medical↗

Correlation-based correction of sound velocity inhomogeneities using delta-sigma modulators.

Delta-sigma (deltasigma) modulator based beamformers have been proposed for high-quality ultrasonic imaging. Due to the high sampling rate and single bit data width, the cost and complexity of the receive beamformer can be significantly reduced. It was shown that with proper dynamic focusing controls, equivalent image quality could be achieved with an adequate signal-to-quantization noise ratio (SQNR). In this paper, deltasigma modulator based beamformers are used for correlation-based phase aberrations correction of sound velocity inhomogeneities in the body. It is shown that the correction can be efficiently implemented at a performance level similar to that of a conventional radio frequency (rf) beamformer. In addition, more than 6 dB contrast improvement is demonstrated. The different dynamic focusing techniques are also investigated in the context of phase aberration correction. It is shown that the single bit dynamic focusing approach does not affect the overall performance of phase aberration correction.

Electronics, Medical↗