Relationship between neurosis and personality disorder.

316 psychiatric patients--predominantly out-patients--with a clinical diagnosis of neurosis (International Classification of Disease), were given an interview schedule for assessing personality disorders. Nearly two fifths were rated as having personality disorder, the anankastic type being the most common and sociopathic personality disorder the least. Patients with anxiety, phobic and obsessional neurosis were all significantly more likely to show personality disorder than those with depressive neurosis. Broadly, passive-dependent personalities were linked to anxiety neurosis, anankastic personality disorder to obsessional neurosis, and both anankastic and passive-dependent personalities to phobic neurosis. In a clinical trial of the efficacy of two dosage regimes of phenelzine in 60 patients the presence of personality disorder significantly impaired clinical outcome. The results suggest strongly that the assessment of personality in neurotic disorders is necessary to make an adequate diagnosis and predict the outcome of treatment.

Clinical Trials as Topic↗

[Antibiotic preparation of the colon or preoperative parenteral prophylaxis in colon surgery. A randomized study].

A double-blind randomised trial was carried out among 72 patients undergoing elective colorectal surgery. 37 patients received Metronidazole and Kanamycin systemically, 35 patients the same medicaments orally. We could not find any difference between the two ways of application. These results are in opposition to those of a comparable study of Birmingham, where the therapy was significantly less successful in the oral group. This fact is discussed and the parenteral, short-term prophylaxis is recommended.

Clinical Trials as Topic↗

A five year study of the incidence of valve-related complications with the Omniscience cardiac prosthesis.

A total of 228 Omniscience cardiac valve prostheses were implanted in 210 patients at two hospitals in Canada from November, 1979 to August, 1984. The 184 operative survivors were followed for a mean duration of 28.5 months (maximum 62.7 months) and for a total of 438 patient-years. Actuarial analysis for AVR, MVR, and all patients showed survival probabilities at five years of 97.2%, 98.9%, and 97.0% respectively. The five-year actuarial probabilities of remaining free of any thrombotic complications were 96.9% for AVR, 96.4% for MVR, and 95.7% overall. When considering only serious thrombotic complications (thromboembolism with deficit or valve thrombosis), the event-free rates are 100% for AVR, 98.9% for MVR, and 98.6% for the overall patient group at five years. These rates for survival and freedom from thrombotic complication demonstrate the clinical safety and effectiveness of the Omniscience prosthesis. In addition, there were no cases of structural failure or intrinsic mechanical malfunction of the prosthesis.