Performances of a multidimensional on-line SPE-LC-ECD method for the determination of three major catecholamines in native human urine: validation, risk and uncertainty assessments.

A novel, multidimensional on-line SPE-LC method with electrochemical detection is described for the fully automated and direct analysis of the catecholamines norepinephrine, epinephrine and dopamine in urine. The integrated extractive clean-up of the raw biofluid is based on a SPE-column packed with restricted access material (RAM) which is modified with the affinity ligand nitrophenylboronic acid. The method was fully validated according to a recent approach based on an accuracy profile. The acceptance limits were set at +/-15% of the nominal concentration values. The method was found accurate over a concentration range from 15 to 500 microg/l for norepinephrine, from 5 to 500 microg/l for epinephrine and from 50 to 500 microg/l for dopamine. The relative risk for the use of the validated method in routine analysis was also assessed based on this validation strategy. It was found that at most 3.5% of future sample measurements will fall outside the acceptance limits. This demonstrates the high reliability of the analytical method described. Moreover, the measurements uncertainties were deduced from the validation experiments without any additional effort.

Catecholamines↗

The transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid in Lidoses: use of total error as decision criterion.

Two new statistical approaches to assess the validity of the transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid were investigated and compared to the conventional approaches generally used in this domain. These new approaches, namely the Tolerance Interval and the Risk approaches, are based on the simultaneous evaluation of the systematic (or trueness) and random (or precision) errors of the transfer into a single criterion called total error (or accuracy). The results of the transfer showed that only the total error based approaches fulfilled the objective of an analytical method transfer, i.e. to give guarantees that each future measurement made by the receiving laboratory will be close enough to the true value of the analyte in the sample. Furthermore the Risk approach was the most powerful one and allowed the estimation of the risk to have future measurements out of specification in the receiving laboratory, therefore being a risk management tool.

Chromatography, Liquid↗

[The transfer of an automated method for the determination of noradrenaline in human urine: using total error as decision criterion].

Two new statistical approaches based on the total error of measurements were applied to the transfer of an automated method for the determination of noradrenalin in human urine by LC-ECD coupled on-line to SPE. They showed that the receiving laboratory was mastering the analytical procedure allowing it to use the method in routine. Furthermore the risk based approach gave guarantee that the risk to have future measurements out of specification in the receiving laboratory was smaller than 5%, therefore being a risk management tool.

Humans↗

[Comparison of three approaches for uncertainty estimation].

Three different approaches for the estimation of uncertainty measurements using the same analytical method were compared, namely validation, robustness and inter-laboratory studies. The uncertainty obtained with the robustness study! predicted well the uncertainty of the inter-laboratory study. On the other hand, the uncertainty estimation obtained with the validation study is lower than those obtained with the two other approaches but is still acceptable as long as the analytical method will be used in a single laboratory.

Chromatography, Liquid↗

On-line coupling of cyclodextrin mediated nonaqueous capillary electrophoresis to mass spectrometry for the determination of salbutamol enantiomers in urine.

The usefulness of the on-line coupling of nonaqueous capillary electrophoresis (NACE) with electrospray ionization (ESI) mass spectrometry (MS) using heptakis(2,3-di-O-acetyl-6-O-sulfo)-beta-cyclodextrin (HDAS-beta-CD) was demonstrated for the enantioselective determination of low concentrations of salbutamol in human urine. After optimization of several parameters, such as sheath-liquid composition and flow rate, nebulizing gas pressure, CE counter-pressure and position of the CE capillary outlet, a limit of quantification of 18 and 20 ng/ml was obtained for salbutamol enantiomers. Moreover, the relative standard deviation values for repeatability at a concentration of 30 ng/ml were below 7% for both enantiomers. Typical regression lines obtained after application of a simple linear regression model revealed a good relationship between peak area and analyte concentration (with 0.9988 and 0.9966 as coefficients of determination). This paper proposes an easy to use and sensitive NACE-MS method to determine enantiomers of a basic chiral drug in biological fluids preceded by solid-phase extraction as sample cleanup.

Adrenergic beta-Agonists↗

Automated method for the determination of a new matrix metalloproteinase inhibitor in ovine plasma and serum by coupling of restricted access material for on-line sample clean-up to liquid chromatography.

A fully automated liquid chromatographic method was developed for the determination of Ro 28-2653, a new synthetic inhibitor of matrix metalloproteinases (MMPs), in ovine serum and plasma. The method was based on the coupling of a pre-column packed with restricted access material, namely LiChrospher RP-8 ADS (alkyl diol silica), for sample clean-up to an analytical column containing octyl silica stationary phase. One hundred microl of biological sample, to which 2-propanol was automatically added, were injected onto the ADS pre-column, which was then washed with a washing liquid consisting of a mixture of 25 mM phosphate buffer (pH 7.0) and acetonitrile (90:10; v/v) for 10 min. By rotation of the switching valve, the analyte was then eluted in the back-flush mode with the LC mobile phase composed of a mixture of acetonitrile and 25 mM phosphate buffer (pH 7.0) (57:43; v/v). The UV detection was performed at 395 nm. The main parameters likely to influence the sample preparation technique were investigated. The method was then validated over a concentration range from 17.5 to 1950 ng/ml, the first concentration level corresponding to the lower limit of quantitation. At this concentration level, the mean bias and the R.S.D. value for intermediate precision were -2.4% and 4.2%, respectively.

Animals↗

Integrated on-line sample clean-up using cation exchange restricted access sorbent for the LC determination of atropine in human plasma coupled to UV detection.

A new, simple and fully automated liquid chromatographic (LC) method with UV detection has been developed for the direct determination of atropine in plasma. Sample clean-up was based on the use of cation exchange restricted access material (RAM) in a pre-column, coupled to LC by means of a column switching system. After direct injection of a 200 microl-volume of plasma sample, the biological matrix was washed out for 10 min using a washing liquid composed of 2 mM lithium perchlorate adjusted to pH 3.0 and methanol (97:3; v/v). By rotation of the switching valve, atropine was then eluted in the back-flush mode for 2 min and transferred to the analytical column packed with octadecyl silica by the LC mobile phase constituted of a mixture of acetonitrile and potassium phosphate buffer (pH 3.0; 50 mM) containing 2 mM sodium heptanesulfonate (16:84; v/v). The UV detection was performed at 220 nm. The method was validated according to a new approach based on accuracy profile over a concentration range from 25 ng/ml, corresponding to the limit of quantitation, to 1000 ng/ml. The method was then applied for the determination of atropine in plasma after intravenous administration to hospitalised patients.

Atropine↗

Development and validation of a fully automated LC method for the determination of cloxacillin in human plasma using anion exchange restricted access material for sample clean-up.

In the framework of a preliminary investigation on the plasma profile of cloxacillin after oral administration, a simple and rapid LC method was developed for the direct determination of this compound in human plasma. The on-line sample clean-up was carried out using a weak anion exchanger (diethylaminoethyl groups) as restricted access material (RAM). The effects of the washing liquid pH, the ionic strength and the addition of organic modifier to the washing liquid were studied in order to obtain an efficient sample clean-up and a high recovery of cloxacillin. The separation was achieved on octadecylsilica stationary phase using a mobile phase consisting in a mixture of phosphate buffer (pH 4.0; 25 mM) and acetonitrile (72:28, v/v). The UV detection was performed at 215 nm. The most appropriate regression model of the response function as well as the limit of quantitation (LOQ) were first selected during the pre-validation step. These criteria were then assessed during the formal validation step. The LOQ was 50 ng/ml. The method was also validated with respect to analyte recovery, precision, trueness, accuracy and linearity. Finally, it was successfully applied for the analysis of the first plasma samples obtained from patients having taken an oral dose of 500 mg cloxacillin.

Anion Exchange Resins↗

Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal--Part I.

This paper is the first part of a summary report of a new commission of the Société Française des Sciences et Techniques Pharmaceutiques (SFSTP). The main objective of this commission was the harmonization of approaches for the validation of quantitative analytical procedures. Indeed, the principle of the validation of theses procedures is today widely spread in all the domains of activities where measurements are made. Nevertheless, this simple question of acceptability or not of an analytical procedure for a given application, remains incompletely determined in several cases despite the various regulations relating to the good practices (GLP, GMP, ...) and other documents of normative character (ISO, ICH, FDA, ...). There are many official documents describing the criteria of validation to be tested, but they do not propose any experimental protocol and limit themselves most often to the general concepts. For those reasons, two previous SFSTP commissions elaborated validation guides to concretely help the industrial scientists in charge of drug development to apply those regulatory recommendations. If these two first guides widely contributed to the use and progress of analytical validations, they present, nevertheless, weaknesses regarding the conclusions of the performed statistical tests and the decisions to be made with respect to the acceptance limits defined by the use of an analytical procedure. The present paper proposes to review even the bases of the analytical validation for developing harmonized approach, by distinguishing notably the diagnosis rules and the decision rules. This latter rule is based on the use of the accuracy profile, uses the notion of total error and allows to simplify the approach of the validation of an analytical procedure while checking the associated risk to its usage. Thanks to this novel validation approach, it is possible to unambiguously demonstrate the fitness for purpose of a new method as stated in all regulatory documents.

Chemistry Techniques, Analytical↗

Fully automated method for the liquid chromatographic-tandem mass spectrometric determination of cyproterone acetate in human plasma using restricted access material for on-line sample clean-up.

A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The method was based on the use of a pre-column packed with internal-surface reversed-phase material (LiChrospher RP-4 ADS, 25 mm x 2 mm) for sample clean-up coupled to LC separation on an octadecyl silica stationary phase by means of a column switching system. A 30 microl plasma sample volume was injected directly onto the pre-column using a mixture of water, acetonitrile and formic acid (90:10:0.1 (v/v/v)) adjusted to pH 4.0 with diluted ammonia as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase consisting of water, methanol and formic acid (10:90:0.1 (v/v/v)). The dispensing flow rates of the washing liquid and the LC mobile phase were 300 microl min(-1). Medroxyprogesterone acetate (MPA) was used as internal standard. The MS ionization of the analytes was achieved using electrospray (ESI) in the positive ion mode. The pseudomolecular ionic species of CPA and MPA (417.4 and 387.5) were selected to generate daughter ions at 357.4 and 327.5, respectively. Finally, the developed method was validated according to a new approach using accuracy profiles as a decision tool. Very good results with respect to accuracy, detectability, repeatability, intermediate precision and selectivity were obtained. The LOQ of cyproterone acetate was 300 pg ml(-1).

Automation↗

Evaluation of a novel anion-exchange restricted-access sorbent for on-line sample clean-up prior to the determination of acidic compounds in plasma by liquid chromatography.

A new kind of silica-based restricted-access material (RAM) with anionic properties has been tested in pre-columns for on-line solid-phase extraction of acidic compounds from directly injected plasma samples prior to their determination by reversed-phase liquid chromatography (LC), using the column-switching technique. The outer surface of the porous RAM particles contains hydrophilic diol groups while diethylaminoethyl (DEAE) groups are bound to the internal surface which gives the sorbent the properties of a weak anion exchanger towards low-molecular-mass compounds. Due to an appropriate pore diameter (about 6 nm), macromolecules, such as proteins, are physically excluded from the pores and flushed directly out during the sample clean-up process, while small compounds have access to the inner surface and can be retained mainly by electrostatic interactions. The retention capability of this novel packing material has been tested for some hydrophilic acidic compounds such as aspartic acid, glutamic acid, ascorbic acid and acetylcysteine as well as for some more hydrophobic drugs such as naproxen, ibuprofen and diclofenac, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The efficiency of the sorbent to clean-up complex matrices was also tested using human plasma and urine samples. A generic washing liquid composition was then selected in order to obtain efficient and selective sample clean-up as well as a high recovery of the acidic analytes.

Acids↗

Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment.

A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).

Androgen Antagonists↗

Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

Anti-Bacterial Agents↗

An analysis of the SFSTP guide on validation of chromatographic bioanalytical methods: progress and limitations.

The Société Française des Sciences et Techniques Pharmaceutiques (SFSTP) published in 1997 a guide on the validation of chromatographic bio-analytical methods, which introduces new concepts in three different areas: stages of the validation, test of acceptability of a method and design of experiments to perform. In 'stages of validation', the SFSTP guide requires two phases to validate a method. The first phase, called 'prevalidation', is intended to (1) identify the model to use for the calibration curve; (2) evaluate the limits of quantitation; and (3) provide good estimates of the precision and bias of the method before designing the 'validation' phase per se. In the 'test of acceptability', the use of the interval hypotheses is envisaged by the SFSTP guide, not on the parameters of bias and precision, but on individual results by mixing mean bias and intermediate precision in a single test. The SFSTP guide also avoids the use of Satterthwaite's df for testing the acceptability. The reasons for those choices are discussed extensively. In 'design of experiments', much effort has been devoted to improving the quality of results by optimally designing and sizing the experiments to perform in validation. The rationale for using near D-optimal designs for the calibration curve is demonstrated and sample sizes are proposed to correctly size the validation experiments.

Chromatography↗

Fully automated LC method for the determination of sotalol in human plasma using restricted access material with cation exchange properties for sample clean-up.

A simple and rapid fully automated bio-analytical method for the liquid chromatographic (LC) determination of sotalol in human plasma has been described. The method is based on the use of a new kind of porous silica restricted access material (RAM) with cation exchange properties for sample clean-up. 100 microl of plasma samples were directly injected into the precolumn coupled on-line to a reversed-phase column (RP-Select B) by means of column switching system. The plasma matrix was washed out for 10 min using a washing liquid composed of 2 mM lithium perchlorate and methanol (97:3; v/v). By rotation of the switching valve, the analytes were then eluted in back-flush mode for 2 min and transferred to the analytical column by the LC mobile phase constituted of a mixture of methanol and 50 mM potassium phosphate buffer (pH 7.0) containing 1 mM 1-octanesulphonic acid sodium salt (20:80; v/v). The flow-rate was 1.0 ml/min and sotalol was detected using fluorescence detection at 235 and 300 nm as excitation and emission wavelengths, respectively. The method was then validated using a new approach based on accuracy profile over a concentration range from 5 to 500 ng/ml. The limit of quantitation (LOQ) was 5 ng/ml and the total analysis time was 19 min.

Cation Exchange Resins↗

Oral bioavailability in sheep of albendazole from a suspension and from a solution containing hydroxypropyl-beta-cyclodextrin.

Albendazole (ABZ) is a benzimidazole derivative with a broad spectrum of activity against human and animal helminthe parasites. ABZ has a very poor aqueous solubility. This study shows that hydroxypropyl-beta-cyclodextrin (HP-beta-CD) is able to form inclusion complexes with ABZ and that is able to increase its aqueous solubility. A synergistic effect exists between HP-beta-CD and citric acid. The combination of HP-beta-CD (200 mM) and citric acid (50 mM) allows dissolution of more than 1.5 mg of ABZ per ml. The aim of this study is the in vivo evaluation in sheep of a solution of the inclusion complex of ABZ with HP-beta-CD in comparison with a suspension of the same drug. A significant (P<0.05) increase in the relative bioavailability is obtained with the solution containing the ABZ-HP-beta-CD complex as measured by ABZSO plasma levels. The area under the curve (AUC(0--> proportional, variant )) of the solution is 37% higher than that obtained with the suspension. Likewise the peak plasma concentration (C(max)) is twice that of the solution while the time to reach C(max) (T(max)) is reduced.

2-Hydroxypropyl-beta-cyclodextrin↗

Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography.

A new kind of silica-based restricted-access material (RAM) has been tested in pre-columns for the on-line solid-phase extraction (SPE) of basic drugs from directly injected plasma samples before their quantitative analysis by reversed-phase liquid chromatography (LC), using the column switching technique. The outer surface of the porous RAM particlescontains hydrophilic diol groups while sulphonic acid groups are bound to the internal surface, which gives the sorbent the properties of a strong cation exchanger towards low molecular mass compounds. Macromolecules such as proteins have no access to the internal surface of the pre-column due to their exclusion from the pores and are then flushed directly out. The retention capability of this novel packing material has been tested for some hydrophilic basic drugs, such as atropine, fenoterol, ipratropium, procaine, sotalol and terbutaline, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The elution profiles of the different compounds and the plasma matrix as well as the time needed for the transfer of the analytes from the pre-column to the analytical column were determined in order to deduce the most suitable conditions for the clean-up step and develop on-line methods for the LC determination of these compounds in plasma. The cationic exchange sorbent was also compared to another RAM, namely RP-18 ADS (alkyl diol silica) sorbent with respect to retention capability towards basic analytes.

Automation↗

Strategy for the development of automated methods involving dialysis and trace enrichment as on-line sample preparation for the determination of basic drugs in plasma by liquid chromatography.

Among the sample preparation techniques, dialysis followed by clean-up and enrichment of the dialysate on a pre-column has proved to be a useful approach for the LC determination of drugs in plasma. By use of sample processors, like the ASTED system, such bioanalytical methods can be fully automated, the dialysis and trace enrichment steps being directly coupled to LC. In order to facilitate the development of such automated methods, a strategy based on a decision tree has been elaborated. After the selection of appropriate conditions for the LC analysis, the decision tree provides information about suggested starting conditions and guidelines for the optimisation of the most important parameters likely to influence analyte recovery and method selectivity. The plasma samples are dialysed on a cellulose acetate membrane in the static-pulsed mode and the dialysate is enriched on a trace enrichment pre-column packed with octadecyl silica or with a strong cation-exchange material. This decision tree is until now restricted to the analysis of basic drugs in plasma. In order to demonstrate the applicability of this method development strategy, an automated procedure based on the coupling of dialysis with trace enrichment has been developed for the LC determination of antifungal agents (clotrimazole, econazole and miconazole) in plasma.

Antifungal Agents↗