PubMed Health⌕ Search

Biomedical subjects

P Clarys

Publications and source records attributed to P Clarys.

15 recordsLinked to original sources

Phosphocreatine degradation in type I and type II muscle fibres during submaximal exercise in man: effect of carbohydrate ingestion.

1. The aim of this study was to examine the effect of carbohydrate (CHO) ingestion on changes in ATP and phosphocreatine (PCr) concentrations in different muscle fibre types during prolonged running and relate those changes to the degree of glycogen depletion. 2. Five male subjects performed two runs at 70 % maximum oxygen uptake (.V(O2,max)), 1 week apart. Each subject ingested 8 ml (kg body mass (BM))(-1) of either a placebo (Con trial) or a 5.5 % CHO solution (CHO trial) immediately before each run and 2 ml (kg BM)(-1) every 20 min thereafter. In the Con trial, the subjects ran to exhaustion (97.0 +/- 6.7 min). In the CHO trial, the run was terminated at the time coinciding with exhaustion in the Con trial. Muscle samples were obtained from the vastus lateralis before and after each trial. 3. Carbohydrate ingestion did not affect ATP concentrations. However, it attenuated the decline in PCr concentration by 46 % in type I fibres (CHO: 20 +/- 8 mmol (kg dry matter (DM))(-1); Con: 34 +/- 6 mmol (kg DM)(-1); P < 0.05) and by 36 % in type II fibres (CHO: 30 +/- 5 mmol (kg DM)(-1); Con: 48 +/- 6 mmol (kg DM)(-1); P < 0.05). 4. A 56 % reduction in glycogen utilisation in type I fibres was observed in CHO compared with Con (117 +/- 39 vs. 240 +/- 32 mmol glucosyl units (kg DM)(-1), respectively; P < 0.01), but no difference was observed in type II fibres. 5. It is proposed that CHO ingestion during exhaustive running attenuates the decline in oxidative ATP resynthesis in type I fibres, as indicated by sparing of both PCr and glycogen breakdown. The CHO-induced sparing of PCr, but not glycogen, in type II fibres may reflect differential recruitment and/or role of PCr between fibre types.

Adult↗

There is no influence of a temperature rise on in vivo adsorption of UV filters into the stratum corneum.

Temperature influences the stratum corneum adsorption of several topically applied compounds. This study was designed to evaluate the influence of the temperature on the stratum corneum adsorption of 3 UV filters. The UV filters were solubilized in two vehicles, an emulsion gel and petroleum jelly and applied at respectively, 31 and 40 degrees C during 30 min. In vivo stratum corneum UV filter content was measured using the tape stripping method. Similar amounts of UV filter were detected in the stratum corneum when comparing applications at the different temperatures. Application of the UV filters in the emulsion gel resulted in higher stratum corneum UV filter concentrations compared with application in the petroleum jelly. The application temperature did not influence the stratum corneum adsorption of the tested UV filters while the nature of the vehicle significantly influenced the amount of UV filters recovered from the stratum corneum.

Adult↗

The Visi-Chroma VC-100: a new imaging colorimeter for dermatocosmetic research.

BACKGROUND/AIMS: It was the aim of this study to carry out a comparative evaluation in vitro on standardized color charts and in vivo on healthy subjects using the Visi-Chroma VC-100, a new imaging tristimulus colorimeter and the Minolta Chromameter CR-200 as a reference instrument. The Visi-Chroma combines tristimulus color analysis with full color visualization of the skin area measured. The technical performances of both instruments were compared with the purpose of validating the use of this new imaging colorimeter in dermatocosmetic research. METHODS: In vitro L*a*b* color parameters were taken with both instruments on standardized color charts (Macbeth and RAL charts) in order to evaluate accuracy, sensitivity range and repeatability. These measurements were completed by in vivo studies on different sites of human skin and studies of color changes induced by topical chemical agents on forearm skin. The accuracy, sensitivity range and repeatability of measurements of selected distances and surfaces in the measuring zone considered and specific color determinations of specific skin zones were also determined. RESULTS: The technical performance of this imaging colorimeter was rather good, with low coefficients of variation for repeatability of in vitro and vivo color measurements. High positive correlations were established in vitro and in vivo over a wide range of color measurements. The imaging colorimeter was able to measure the L*a*b* color parameters of specific chosen parts of the skin area considered and to measure accurately selected distances and surfaces in the same skin site considered. CONCLUSION: These comparative measurements show that both instruments have very similar technical performances and that high levels of correlation were obtained in vitro and in vivo using the L*a*b* color parameters. In addition, the Visi-Chroma presents the following improvements: 1) direct visualization and recording of the skin area considered with concomitant color measurements; 2) determination of the specific color parameters of skin areas chosen in the total measuring area; and 3) accurate determination of selected distances and surfaces in the same skin areas chosen.

Colorimetry↗

A comparative study of the effects on the skin of a classical bar soap and a syndet cleansing bar in normal use conditions and in the soap chamber test.

BACKGROUND/AIMS: The skin irritation potential of a body cleansing product is often compared under exaggerated test conditions, although the product is intended to be used at home with repetitive and brief contact with the skin. The aim of this study was to determine how much patch testing is predictive of the clinical, sub-clinical and subjective cutaneous effects of products used at home by consumers for their normal hygienic cleansing. METHODS: A double-blind comparative study of the normal use of an alkaline soap bar and a syndet at home during 10 consecutive weeks was performed on two identical groups of 25 healthy female subjects. The eventual skin changes observed at different anatomical skin sites were evaluated by clinical visual examination and by bioengineering measurements before the start of the study and then every 2 weeks. The objective measurements were compared with the subject's perceptions of dryness, tightness and product irritancy during the testing. RESULTS: The bioengineering measurements did not show any significant changes on all the anatomical skin sites, except for a small increase in skin pH with the classical soap bar. However, a trend appeared, showing that the alkaline soap bar is perceived by the subjects themselves as more of an irritant than the syndet bar. In the soap chamber test, the bar soap showed a significantly higher irritancy than the syndet bar. CONCLUSION: This study showed that cutaneous irritation induced by cleansing products in patch testing is not necessarily predictive of the irritation likely to occur in normal use conditions. Finally, a clear relationship could be demonstrated between the results of the soap chamber test and the consumer perception of both cleansing bars.

Adult↗

Growth, development, and physical fitness of Flemish vegetarian children, adolescents, and young adults.

This study was designed to assess average daily dietary intakes of energy in 82 vegetarian children (group A: 6- 9-y-old girls and 6-11-y-old boys), adolescents (group B: 10- 15-y-old girls and 12-17-y-old boys), and young adults (group C: 16-30-y-old females and 18-30-y-old males) and included determination of height and weight; triceps, suprailiac, and calf skinfold thicknesses; puberty ratings; and physical fitness. Dietary energy intake was lower than recommended values in all 3 groups. Height and weight did not differ significantly from the reference data except in group B, which had significantly lower heights and weights and lower body mass indexes (P<0.05). Triceps and suprailiac skinfold thicknesses were lower in all age groups, whereas the calf skinfold thickness was only significantly lower in the 10-15-y-old girls (P<0.05). The vegetarian children were as physically fit as the reference group. The vegetarian adolescent boys and girls and the young adults scored significantly lower on the standing long jump and 30-s sit-up (P<0.05). The vegetarian subjects of groups B and C recovered significantly faster from the step test (P<0.05). Puberty ratings plotted on percentile graphs showed that all vegetarian subjects, except for 1 girl, were within the normal developmental range. We conclude that, within the limits of this study, vegetarian subjects have lower relative body weights and skinfold thicknesses in adolescence than do nonvegetarians. They scored lower on the strength tests and better on the cardiorespiratory test when compared with reference values. The growth and maturation status of the vegetarian population were within the normal range.

Adolescent↗

In vitro percutaneous penetration through hairless rat skin: influence of temperature, vehicle and penetration enhancers.

Theoretically, a positive relation is expected between skin temperature and the percutaneous penetration of topically applied substances. The aim of the present study was to evaluate the influence of the temperature on the in vitro percutaneous penetration of dihydrotestosterone. Hairless rat skin was mounted in static diffusion cells placed in a water bath at different temperatures (28.6, 35.1 and 38.2 degrees C, respectively). Different vehicles were tested as well as the addition of penetration promoting molecules such as oleic acid and limonene. A saline buffer was used as the receptor phase. Penetration through the skin was evaluated by means of scintillation counting of the radiolabelled dihydrotestosterone. Experiments were followed for a period of 29 h. The total amount of penetrant, dihydrotestosterone, as well as the flux, were calculated from these kinetics. Our results demonstrate a temperature effect with the highest penetration at 38.2 degrees C. The vehicle was also found to influence the penetration of dihydrotestosterone in a significant way. Furthermore, limonene presented better penetration promoting properties compared with oleic acid.

Administration, Topical↗

Efficacy of topical treatment of pigmentation skin disorders with plant hydroquinone glucosides as assessed by quantitative color analysis.

Hydroquinone is a well known reagent used in the treatment of pigmentation disorders. The instability of the quinones and the required active concentration make topical treatment rather difficult. We tested the efficacy of an ascorbate-phytohydroquinone complex that inhibits the synthesis of melanin and promotes the degradation of the existing melanin. Lentigo senile lesions were evaluated before and after 1 month of treatment. Objective skin color evaluation was performed instrumentally. After one month of treatment, a clear depigmentation of the macules was measured. None of the volunteers reported any side effects from the prolonged treatment with the hydroquinone containing product.

Administration, Cutaneous↗

Influence of temperature on irritation in the hand/forearm immersion test.

As indicated by in vitro experiments the penetration of irritants through the skin is significantly influenced by the temperature of the solution. In vivo experiments, demonstrated equally a significant influence of temperature in surfactant-induced skin irritation. In order to evaluate the irritant potential of detergent solutions under normal user conditions, we used the hand/forearm immersion test. We compared 2 detergents with different anionic character in a repetitive immersion protocol (30 min immersion on 4 consecutive days). The solutions were tested at 2 temperatures (37 degrees C and 40 degrees C). The irritation was quantified by assessment of the stratum corneum barrier function (transepidermal water loss), skin redness (a* colour parameter) and skin dryness (capacitance method). Both detergents affected the integrity of the skin in a significant way. The anionic content as well as the temperature of the solutions were found to be determinative for the irritant potential, with a stronger response for higher anionic content and temperature, respectively.

Adult↗

Study of the stratum corneum barrier function by transepidermal water loss measurements: comparison between two commercial instruments: Evaporimeter and Tewameter.

The measurement of transepidermal water loss (TEWL) is an important noninvasive method in order to assess the barrier function of the stratum corneum. As a consequence, TEWL has been found to be a very useful technique for studying skin irritation induced by various physical and chemical effects. Exposure of the skin to chemicals (detergents) and physical conditions (occlusion and stripping) generally results in an increase of TEWL. Until recently the only commercially available TEWL instrument was the Evaporimeter developed by ServoMed (Sweden). The instrument is based on the open chamber system with two humidity and temperature sensors which measure the water evaporation gradient at the surface of the skin. Recently a new commercially available instrument based on the same physical principle of measurement was developed by Courage and Khazaka (Tewameter, FRG). Our aim in this study has been to compare the measuring capacities of both instruments. The accuracy, sensitivity, variability and reproducibility of both instruments were compared in vivo under identical conditions on normal skin and skin damaged by external conditions. The influence of external and environmental factors such as air and probe temperature, relative humidity, air turbulence and pressure of application was evaluated for both instruments. Finally, the two instruments were compared in practice when following the increase in TEWL of the skin after stripping, occlusion and exposure to irritant household detergents. A very good correlation (r = +0.97) was found between the results of the two instruments over a wide range of TEWL values.

Adolescent↗

Quantitative evaluation of skin surface lipids.

More than 50 years of noninvasive studies of epidermal and sebaceous lipids has revealed a vast amount of information concerning secretion and regulation of SSLs. The first techniques developed (solvent extraction and cigarette paper) required very long experimental procedures to obtain valuable parameters; however, a great part of the knowledge on SSL production and regulation was obtained by these pioneers. Because of the difficulties encountered in these multistep procedures, applicability was restricted to a limited number of research centers. The sampling procedures in the newly developed techniques are significantly reduced and are followed by a fast and accurate evaluation. Moreover, the new sampling procedures permit us to study other aspects of sebum secretion, as demonstrated with the Sebutape method. When using photometric techniques an estimate of the SSL can be obtained within minutes (casual level measurements). After such a screening procedure, more standardized parameters can be accurately determined. Whatever the parameter under investigation, strictly controlled experimental procedures are required. Control of temperature and relative humidity of the experimental room, of the acclimatization periods, and of the volunteers during the collection periods is of capital importance. The studies discussed in this article clearly demonstrate the applicability of the new techniques not only for research and cosmetic purposes but also for clinical use.

Chemistry Techniques, Analytical↗

A qualitative estimate of the influence of halcinonide concentration and urea on the reservoir formation in the stratum corneum.

The existence of a stratum corneum reservoir for topically applied substances is well known. Data concerning the stratum corneum retention time are important for the elaboration of optimal topical treatment. We used the re-occlusion technique followed by skin colour measurements (Chromametry) for the evaluation of the stratum corneum retention time of halcinonide. We found a significant reservoir for halcinonide up to 5 days after the initial application. The retention was found to be corticosteroid concentration and formulation dependent.

Administration, Topical↗

In vivo tolerance assessment of skin after insertion of subcutaneous and cutaneous microdialysis probes in the rat.

The purpose of the study was to evaluate the trauma induced by insertion of the linear microdialysis probe in the subcutaneous and dermal tissue in the rat and to check if the microdialysis probe insertion affects transdermal drug delivery. Non-invasive bioengineering methods (TEWL, Laser Doppler Velocimeter, Chromameter) as well as histology were combined to characterize these effects. The results showed that the dermal and subcutaneous insertion of microdialysis probes did not change skin permeability, blood flow and color, confirming the safety of this technique. The probe depth did not influence the trauma. No significant physical damage after probe insertion was noticed. Thus, the present work validates the use of microdialysis in dermatopharmacokinetics studies after topical or systemic drug delivery.

Administration, Cutaneous↗