PubMed Health⌕ Search

Biomedical subjects

P Coruzzi

Publications and source records attributed to P Coruzzi.

54 records · Page 3Linked to original sources

[Physiopathological and functional semeiologic considerations in a case of primary normoaldosteronemic hyperaldosteronism].

Among the atypical pictures of primary aldosteronism, sometimes, normal blood and urine concentration of aldosterone have been observed in association with an adrenal aldosterone-producing adenoma. Here we report a case of atypical primary aldosteronism so characterized: -- the patient had the typical clinical findings of aldosteronism (hypertension, hypokalemic alkalosis, polyuria, etc). -- the patient exhibted all the biochemical abnormalities of primary aldosteronism: increase of exchangeable Na and of plasma volume, decrease of exchangeable K, etc. -- the patient had normal blood and urine levels of aldosterone. -- the patient's blood and urine aldosterone concentration increased following sodium depletion and K administration. Such increase was comparable with that obtained in normal subjects after the same tests. However, at the end of these tests, the patient was still in potassium depletion and sodium repletion. Therefore, it was concluded that the secretion of aldosterone, although normal in absolute values, was inappropriate to the metabolic status of the patient, since such "normal" values were found in association with conditions that should have produced an inhibition of aldosterone production. The catheterization of adrenal veins demonstrated the existence of a right adrenal adenoma. The blood pressure and the biochemical parameters of the patients have been normalized by right adrenalectomy.

Adenoma↗

[Notes on a case of clinostatic chyluria].

A clinical case of clinostatic chyluria of unknown non-parasitic aetiology, is reported. Ascending pyelography showed the presence of lymphatic communications between right renal pelvis and homolateral lumbo-aortic lymph nodes. Aetiology, pathogenesis, prognosis and diagnostic tools of use in the syndrome are discussed. The problem of the possible lymphatic origin of benign proteinuria, in relation to anatomic considerations and to quality and quantity resemblances between individual protein fractions in chyluria and benign proteinuria encountered in the present case, is also discussed. In order to clarify the problem, emphasis is laid on the advisability of simultaneously studying urinary protein composition in postural chyluria and lipid composition in benign proteinuria.

Chyle↗

Glycolipid modifications during peritoneal dialysis in patients with chronic renal failure.

Ten patients with progressive CRF were studied for the major indices of glycolipid metabolism during the first application of peritoneal dialysis. From the 2nd hour the concentration of dialysis fluid is 4.5g%, while the electrolyte content is unchanged. During treatment a constant increase of glycemia and insulinemia with a fall of plasma-free fatty acids and serum triglycerides was observed. The authors attribute such modifications to hyperglycemia and consequently to the high glucose of the dialysis bath.

Adult↗

Diagnostic accuracy of 16-row multislice CT angiography in the evaluation of coronary segments.

PURPOSE: To evaluate the diagnostic accuracy of 16-row multislice spiral computed tomography coronary angiography (16-MSCT-CA) for the non-invasive assessment of significant coronary artery stenosis. MATERIALS AND METHODS: We enrolled 40 patients (36 male, aged 59+/-11 yrs) with suspected obstructive coronary artery disease and a heart rate <65 bpm during the scan. The 16-MSCT-CA (Sensation 16, Siemens, Forchheim, Germany) was performed with electrocardiographically-gated technique after the intravenous administration of 100 ml of iodinated contrast material followed by a saline bolus chaser. The scan parameters were: collimation 16 x 0.75 mm, rotation time 0.42 s, feed/rot. 3 mm (pitch 0.25), 120 kVp, 500 mAs. All coronary segments = or >2 mm in diameter were evaluated by two independent observers for the presence of significant coronary artery stenosis (= or >50%). Consensus reading was compared to quantitative coronary angiography. RESULTS: The average heart rate was 55+/-6 bpm. Of the 428 segments of = or >2.0 mm diameter 92 were significantly diseased. Without exclusion of any branches (428), the sensitivity, specificity, positive, and negative predictive values to identify = or >50% obstructed segments were 95.7% (88/92), 95.8% (322/336), 86.3% (88/102), and 98.8% (322/326), respectively. No occluded left main, left anterior descending, circumflex or right coronary artery segments remained undetected. CONCLUSIONS: 16-MSCT-CA in a selected low-heart-rate patient population provides high diagnostic accuracy in the evaluation of significant coronary artery stenosis.

Contrast Media↗

Non-invasive assessment of coronary artery stent patency with multislice CT: preliminary experience.

PURPOSE: To evaluate the diagnostic accuracy of multislice computed tomography coronary angiography (MSCT-CA) in the detection of in-stent restenosis. MATERIALS AND METHODS: Forty-two patients (33 male, 9 female, mean age 58+/-8 years) previously subjected to percutaneous implantation of coronary stent with suspected in-stent restenosis, underwent a 16-row MSCT (Sensation 16, Siemens) examination. The average time between stent implantation and MSCT-CA was 7.4+/-5.3 months. The following scan parameters were used: collimation 16x0.75 mm, rotation time 0.42 s, feed 3.0 mm/rot., kV 120, mAs 500. After administration of iodinated contrast material (Iomeprol 400 mgI/ml, 100 ml at 4 ml/s) and bolus chaser (40 ml of saline at 4 ml/s) the scan was completed in <20 s. All segments with a stent were assessed by two observers in consensus and were graded according to the following scheme: patent stent, in-stent intimal hyperplasia (IIH) (lumen reduction <50%), in-stent restenosis (ISR) (=/>50%), in-stent occlusion (ISO) (100%). Consensus reading was compared with coronary angiography. RESULTS: Forty-seven stents were assessed (16 in the right coronary artery; 4 in the left main; 22 in the left anterior descending; 5 in the circumflex). In 7 (17%) stents there was ISR (3) or ISO (4), and in 4 (10%) stents there was IIH. The sensitivity and negative predictive values for the detection of ISO were 80% and 98%, respectively, while for the detection of ISR+ISO they were 50% and 89%, respectively. CONCLUSIONS: Although the results are encouraging, the follow-up of stent patency with MSCT-CA does not show a diagnostic accuracy suitable for clinical implementation.

Journal Article↗

[Drug therapy of pheochromocytoma].

The Authors briefly review the clinical findings, the diagnostic biochemical procedures and the management of pheochromocytoma. The most recent pharmacological approaches with calcium-channel blockers or angiotensin-converting enzyme inhibitors are particularly discussed.

Adrenal Gland Neoplasms↗