PubMed Health⌕ Search

Biomedical subjects

P D Angus

Publications and source records attributed to P D Angus.

11 recordsLinked to original sources

Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.

We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.

Aged↗

The hydroxyapatite-coated JRI-furlong hip. Outcome in patients under the age of 55 years.

We present the clinical and radiographic outcome of 68 consecutive primary total hip replacements performed in 54 patients under the age of 55 years using a hydroxyapatite-coated femoral component and threaded cup with a modular ceramic head (JRI-Furlong). We reviewed 62 (91%) hips at a median follow-up of 8.8 years (5 to 13.8) after implantation; six (9%) were lost to follow-up. At review there had been four (6%) revisions but only one for aseptic loosening (acetabulum). Radiographic review of the remaining hips did not identify any evidence of femoral or acetabular loosening. The median Harris and Merle d'Aubigné and Postel hip scores were 95.9 (42.7 to 100) and 17 (3 to 18) respectively. The JRI-Furlong hip gives promising functional and radiographic results in young patients in the medium term.

Adult↗

Patellar fracture following surgery for patellar instability.

We present a case of patellar fracture in a teenager that followed a soft tissue realignment surgery for patellar instability. We propose that this fracture was due to disruption of the blood supply to the patella as a result of the procedure. To our knowledge this complication, which has been documented following Total Knee Arthroplasty, has not been documented in the English literature before.

Adult↗

Aspects of column fabrication for packed capillary electrochromatography.

Various parameters have been evaluated to develop a process for optimization of column manufacture for packed capillary electrochromatography (CEC). Spherisorb ODS-1 was packed into 75 microm I.D. capillaries to establish a standard set of packing conditions to afford high-performance columns free of voids. Numerous silica-based packing materials including porous and non-porous reversed-phase and ion-exchange phases were employed to evaluate the applicability of the standard conditions. Success of column manufacture and performance demonstrate a relationship to the colligative properties of the packing materials under the applied conditions. Frequently encountered difficulties arising from inadequate column conditioning and void formation in the packed bed are identified and discussed.

Electrophoresis, Capillary↗

Evaluation of 1.5 microM reversed phase nonporous silica in packed capillary electrochromatography and application in pharmaceutical analysis.

Reversed-phase nonporous silica (RP-NPS) of 1.5 microm dp is employed to demonstrate rapid and efficient separations in packed capillary electrochromatography (CEC). Two methods for packing capillaries and two techniques to manufacture frits used to hold the packing in place are evaluated for their effect upon separation performance using polyaromatic hydrocarbons (PAHs) and polar neutral pharmaceutical compounds. Attention is given to conditioning of the packed capillaries for high efficiency separations without necessity for sodium dodecyl sulfate (SDS). Separation conditions for the nonporous materials were modified from those previously determined on porous reversed-phase silica. Feasibility for method development and validation of a parent pharmaceutical compound and related impurities in the range of 0.1-120% of a 5 mg/mL concentration was assessed and reported. An approach to improving detection sensitivity through use of large-bore capillaries is briefly discussed.

Anthracenes↗

Method development in pharmaceutical analysis employing capillary electrochromatography.

Capillary electrochromatography (CEC) has been employed to explore method development for a series of structurally related polar neutral compounds of pharmaceutical relevance. Capillaries with dimensions of 75 microm ID x 25 cm length (34.5 cm total) were packed with Spherisorb ODS-1, Hypersil phenyl, and Hypersil MOS (all 3 microm particles) and were compared in the reversed-phase mode in order to determine which phase provided the best initial performance and thus serve as the phase of choice for additional method development experiments. The various separation parameters examined for their effect on efficiency, k', resolution, and linear velocity included percent and type of organic modifier, buffer concentration, voltage, and temperature. All separations were conducted with an acidic mobile phase (aqueous mobile phase component, pH 3.0). The separation efficiencies obtained were on the order of 200,000-260,000 plates/m, which equates to reduced plate heights of 1.22 for columns packed with Spherisorb ODS-1. Repeatable column-to-column separation performance was demonstrated.

Acetonitriles↗

The importance of elbow aspiration when treating radial head fractures.

A prospective study of elbow aspiration was performed to assess the effect of this procedure on pain relief and function following Type I and II fractures of the radial head. Aspiration of the haemarthrosis produced dramatic pain relief in 77% of elbows thus treated. Earlier return of function was also noted for these elbows compared to controls. We recommend elbow aspiration for patients with these fractures to both relieve pain and restore early function.

Adolescent↗

Simultaneous bilateral rupture of the quadriceps tendon.

The simultaneous, complete rupture of both quadriceps tendons is a rare event. Only 30 previous cases have been reported and the majority have had well-documented predisposing factors, such as chronic renal failure, gout, hyperparathyroidism, diabetes and obesity. We report a case which presented without any predisposing cause, and review the literature to date.

Aged↗

Triple arthrodesis. A critical long-term review.

The results of triple arthrodesis performed in 80 feet and followed for an average of 13 years are reviewed. Although the majority of patients were very pleased, the results of objective assessment were less favourable. There was a high incidence of degenerative joint changes in the ankle and midfoot and also of pseudarthrosis, avascular necrosis of the talus and residual deformity. Pre-operative rigid equinovarus deformity produced the majority of the poor results. It is suggested that bony resection alone might not be the best means of correcting severe equinus.

Adolescent↗

Posterior spinal fusion without blood replacement in Jehovah's Witnesses.

Posterior spinal fusion without blood replacement is a formidable procedure that most orthopedic surgeons are reluctant to attempt. This procedure has been performed without transfusions on 19 patients, all of whom were Jehovah's Witnesses. The operations were performed over four spinal segments at a time and were planned so that the procedure could be terminated when 10% of the patient's estimated total blood volume had been lost. Allogeneic donor bone was used to minimize blood loss whenever this was acceptable to the patient. The procedure was associated with a high incidence of pseudarthrosis, all cases of which occurred when allogeneic bone was used. No deaths or life-threatening complications were encountered. Thus, posterior spinal fusion can be performed in Jehovah's Witnesses without transfusion, but the procedure should be conducted only by the experienced spinal surgeon.

Adolescent↗

The pneumatic tourniquet and deep venous thrombosis.

The effect of the pneumatic tourniquet on the incidence of postoperative deep venous thrombosis is uncertain. We carried out a controlled study comparing the incidence of deep venous thrombosis when a tourniquet was used with the incidence when a tourniquet was not used. Thrombosis was detected by radioisotope venography. The results of the study showed no difference in incidence and we concluded that the pneumatic tourniquet has no influence on the formation of a thrombus in a deep vein.

False Negative Reactions↗