Comparison of efficacy of automatic implantable cardioverter defibrillator in patients older and younger than 65 years of age.

PURPOSE: The efficacy of the automatic implantable cardioverter defibrillator (AICD) was compared in elderly patients and younger patients with life-threatening ventricular tachyarrhythmias. Clinical characteristics, surgical complications, and long-term survival rates were compared between the two age groups. PATIENTS AND METHODS: A retrospective study was conducted of 54 elderly patients (greater than 65 years) and 79 younger patients (less than 65 years) who had had AICDs implanted for recurrent symptomatic ventricular tachycardia and/or ventricular fibrillation. RESULTS: In 85% of elderly patients and 78% of younger patients, coronary artery disease was the underlying disease (NS). The mean left ventricular ejection fraction was 31.4 +/- 14.3% in the elderly patients and 35.7 +/- 17.6% in the younger patients (NS). Concomitant myocardial revascularization was performed in 37% of elderly patients and 29% of younger patients (NS); however, only 4% of elderly patients had concomitant left ventricular resection or cryoablation, compared with 15% of younger patients (p less than 0.001). Two patients in each age group died perioperatively (4% versus 3%, NS), and no significant difference in surgical morbidity or length of hospital stay following AICD implantation was noted between the age groups. In conjunction with AICD, elderly patients more commonly received antiarrhythmic drugs, with 54% of elderly patients taking amiodarone at the time of hospital discharge compared with 29% of the younger patients (p less than 0.008). In contrast, beta-blockers were more commonly used in younger patients (16% versus 2%, p less than 0.03). At a mean follow-up of 25 months, 11 (20%) elderly patients and 16 (20%) younger patients had died. Six deaths in elderly patients and five deaths in younger patients were classified as arrhythmic deaths (NS); however, only one younger patient and three elderly patients died suddenly (NS). Calculated survival curves demonstrated similar survival rates in the two age groups with approximately 90%, 87%, and 80% of the patients alive at 1, 2, and 3 years, respectively. Theoretic survival curves calculated from appropriate AICD shocks demonstrated significantly lower survival compared with actual survival. CONCLUSION: It is concluded that AICD is a very effective treatment for life-threatening ventricular tachyarrhythmias, and this benefit applies to elderly patients as well as younger patients.

Adolescent↗

Prehospital prophylactic lidocaine does not favorably affect outcome in patients with chest pain.

STUDY OBJECTIVES: The purpose of our study was to determine the morbidity and mortality in initially stable patients presenting to paramedics with chest pain; to examine possible beneficial effects of its use, including reduction of sudden death syndrome in the prehospital and emergency department setting; and to determine if prophylactic lidocaine is associated with adverse effects in this patient population. DESIGN AND SETTING: This was a randomized, prospective study using prophylactic lidocaine in patients complaining of chest pain who presented to our paramedic system between January 1984 and January 1988. TYPE OF PARTICIPANTS: All patients aged 18 years or older with chest pain of suspected cardiac origin who presented to paramedics during the study period were included. Excluded were patients presenting with warning arrhythmias, second- or third-degree heart block, bradycardias of less than 50, hypotension of less than 90 mm Hg systolic, or known allergy to lidocaine. INTERVENTIONS: Patients were randomized into two groups, the lidocaine-treated group and the control group. An initial bolus of 1 mg/kg IV lidocaine was administered to the lidocaine-treated group. A simultaneous 2 mg/min IV drip was established. Ten minutes after the first dose of lidocaine, a second bolus of 0.5 mg/kg was administered. MEASUREMENTS AND MAIN RESULTS: During the study period, 1,427 patients were entered; 704 received lidocaine, and 723 did not. Discharge diagnoses included acute myocardial infarction (31%), unstable angina (33%), other cardiac problems (7%), and noncardiac problems (29%); overall mortality rate was 7.4%. There was an equal distribution of deaths between the lidocaine-treated group (57) and the control group (48). Six patients had a cardiac arrest in the prehospital setting, and 15 had a cardiac arrest in the ED. Malignant ventricular arrhythmias as the precipitating arrest rhythm in patients with acute myocardial infarctions were similar for the lidocaine-treated and control groups. The incidence of adverse effects, including hypotension, bradycardias, second- or third-degree heart blocks, tinnitus, and altered mental status, was similar in both groups. CONCLUSION: There are no benefits from the administration of prehospital prophylactic lidocaine in stable patients with chest pain; therefore, routine use in this setting appears unwarranted.

Chest Pain↗

Congenital hypertrophy of retinal pigment epithelium: a sign of familial adenomatous polyposis.

Families of people known to have familial adenomatous polyposis are screened for signs of the disease by yearly examination of the bowel. Multiple areas of congenital hypertrophy of the retinal pigment epithelium have been described in patients with familial adenomatous polyposis. To assess the reliability of this marker 40 patients with familial adenomatous polyposis, representing all 25 pedigrees with living affected members in the Northern region's polyposis registry, were examined for hypertrophy of the retinal pigment epithelium. All had multiple lesions, ranging in number from two to over 40. None of the 35 controls had more than two lesions. Ocular examination is valuable for detecting carriers of the gene for familial adenomatous polyposis before their symptoms develop.

Adenomatous Polyposis Coli↗

Comparison of monophasic with single and dual capacitor biphasic waveforms for nonthoracotomy canine internal defibrillation.

Monophasic and single capacitor and dual capacitor biphasic truncated exponential shocks were tested in pentobarbital-anesthetized dogs with use of a nonthoracotomy internal defibrillation pathway consisting of a right ventricular catheter electrode and a subcutaneous chest wall patch electrode. Seven dogs weighing 20.2 +/- 0.5 kg were utilized. Monophasic pulses of 10 ms duration were compared with three biphasic pulses. All biphasic waveforms had an initial positive phase (P1) followed by a terminal negative phase (P2) and the total duration of P1 plus P2 was 10 ms. The dual capacitor biphasic waveform (P1 9 ms, P2 1 ms) had equal initial voltages of P1 and P2. Two simulated single capacitor biphasic waveforms were also tested, the first designed to minimize the magnitude of P2 (P1 9 ms, P2 1 ms with initial voltage of P2 equal to 0.3 of the initial voltage of P1) and the second to maximize P2 (P1 5 ms, P2 5 ms with initial voltage of P2 = 0.5 P1). Alternating current was used to induce ventricular fibrillation and four trials of eight initial voltages from 100 to 800 V were performed for each of the four waveforms. Stepwise logistic regression was utilized to construct curves relating probability of successful defibrillation and energy. In the logistic model, the dual capacitor biphasic and single capacitor biphasic waveforms that maximized P2 were associated with significantly (p less than 0.001) lower energy requirements for defibrillation than those of the monophasic waveform. The single capacitor biphasic waveform that minimized P2 was not significantly better than the monophasic waveform.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

The implantable defibrillator and the emergency physician.

The automatic implantable cardioverter defibrillator (AICD) is a proven therapy for preventing the potentially lethal consequences of recurrent ventricular arrhythmias. Given the ever-increasing number of patients who have these devices, it can be anticipated that an increasing number of these patients will likely present to emergency departments with problems associated with this therapy. We review normal automatic implantable cardioverter defibrillator function and focus on the evaluation and treatment of problems that may bring a patient to the ED. Included are interaction with the device by magnets, assessment of the propriety of shocks received by the patient, and what to do when patients state they have received a shock from the device. An algorithmic approach is presented to facilitate management of these patients.

Electric Countershock↗

Long-term internal cardiac defibrillation threshold stability.

The automatic implantable cardioverter-defibrillator is tested intraoperatively with defibrillation trials to ensure effectiveness. It is unknown if the energy requirement for internal defibrillation remains stable and that once demonstrated effective, if the device will continue to be effective in terminating lethal ventricular arrhythmias. In this study, the defibrillation energy requirement was compared in 56 patients at the time of lead implantation to that obtained at the time of generator replacement. Mean time to generator replacement was 17. +/- 6.6 months. The defibrillation threshold was stable over that time (11.9 +/- 6.7 joules compared to 12.7 +/- 8.4 joules, NS). There was no relation between transmyocardial impedance and defibrillation threshold. In addition, no effect on defibrillation threshold was demonstrated by the use of various cardiac medications, concomitant surgery or the occurrence of clinical shocks during follow-up.

Electric Countershock↗

Complications of automatic implantable cardioverter defibrillators: radiographic, CT, and echocardiographic evaluation.

Automatic implantable cardioverter defibrillators (AICDs) were studied in three groups: (a) Serial radiographs were reviewed in 51 clinic patients. Twenty of 96 (21%) AICD patches distorted with time. (b) Thirty-six postoperative computed tomographic (CT) scans of asymptomatic patients revealed that pericardial fluid collections were frequent during the month after surgery but rare beyond that. Echocardiography was insensitive for these collections. CT also demonstrated dense fibrosis around some distorted patches, months after surgery. (c) Five other patients with pericardial infection had distorted patches, and the four studied with CT had fluid beneath their patches. (d) A case of constrictive pericarditis had distorted patches but was not diagnosed with CT. The authors conclude that distorted patches may indicate postoperative complications and that CT is the imaging modality of choice.

Arrhythmias, Cardiac↗

Spontaneous recovery of left ventricular function following acute anterior myocardial infarction.

Four patients with acute anterior wall myocardial infarction showing spontaneous and marked improvement in systolic left ventricular function are described. All 4 patients showed abnormal Q waves and severe wall motion abnormalities soon after acute infarction. In all 4 patients, at least some regeneration of R-wave forces occurred and the regional wall motion in the involved area of the left ventricle improved dramatically without coronary angioplasty or surgical revascularization during the intervening period. The improvement in left ventricular function was attributed to spontaneous increase in nutrient flow to the involved area. It is concluded that Q waves and severe wall motion abnormalities do not necessarily indicate irreversible scar formation.

Electrocardiography↗

Comparative efficacy of monophasic and biphasic truncated exponential shocks for nonthoracotomy internal defibrillation in dogs.

Pentobarbital-anesthetized dogs were studied to determine the relative efficacy of monophasic and biphasic truncated exponential shocks employing a nonthoracotomy internal defibrillation pathway that consisted of a right ventricular catheter electrode (cathode) and a subcutaneous chest wall patch electrode (anode). In part 1 of the experiments, six dogs (19.6 +/- 1.1 kg) were utilized. Monophasic pulses of 5, 7.5, 10 and 12.5 ms duration were compared with biphasic pulses of the same total duration. The biphasic pulses had an initial positive phase (P1) followed by a terminal negative phase (P2) with the initial voltage equal for each phase. For each biphasic total pulse width, five relative P1 versus P2 durations were tested (50 and 50%, 75 and 25%, 90 and 10%, 25 and 75%, 10 and 90%). Ventricular fibrillation was induced by alternating current and pulse configurations were tested randomly to determine the minimal voltage and energy for defibrillation (threshold). Biphasic shocks with P1 longer than P2 were associated with significantly lower (p less than 0.01) energy thresholds than were monophasic shocks. Additionally, there was no significant relation between pulse width and voltage or energy thresholds. In part 2 of the experiments, six dogs (20.2 +/- 1.6 kg) were studied. Monophasic shocks were compared with biphasic shocks with P1 versus P2 durations of 75 and 25% and 90 and 10% for total pulse widths of 7.5, 10 and 12.5 ms. Threshold determinations were performed as in part 1. Subsequently, five initial voltages clustered about threshold were randomly tested four times and dose-response curves constructed for each pulse configuration with the use of stepwise logistic regression. Biphasic shocks resulted in significantly lower energy (p less than 0.0001) and voltage (p less than 0.001) requirements than did monophasic shocks.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs.

Six anesthetized dogs (wgt 19.6 + 1.1 kg) underwent defibrillation trials using truncated monophasic pulses of 2.5-20 msec in duration. The current pathway consisted of a 4 cm2 RV catheter electrode (cathode) and a 13.9 cm2 subcutaneous chest wall patch (anode). Fibrillation was induced by alternating current and defibrillation attempted 10 seconds later. Only one test shock was assessed for each fibrillation episode. The various durations were tested randomly, and the minimum peak voltage and energy resulting in defibrillation was determined for each. Shorter pulse durations were associated with lower energies with pulses of 2.5-15 msec having significantly lower energy thresholds than shocks of 20 msec (P less than 0.05). The relationship between duration and voltage threshold is hyperbolic with minimum voltage between 7.5 and 12.5 msec while the shortest and longest pulses were associated with the highest voltage thresholds. Shocks of 5 to 15 msec were associated with significantly lower voltage threshold than 2.5 msec pulses (P less than 0.05). The threshold average current (Iav) reached a nadir at 10 msec. Shocks in the midrange of those tested resulted in the best combination of low average current and energy requirements for defibrillation using this nonthoracotomy lead system.

Animals↗

Sequential shocks are comparable to single shocks employing two current pathways for internal defibrillation in dogs.

Sequential pulse defibrillation using two current pathways was compared with single shocks simultaneously utilizing both pathways in 16 dogs to assess the effects of temporal summation. A cardioverter-defibrillator catheter was positioned via the external jugular vein with the distal 4 cm2 shocking electrode located in the right ventricular apex and the proximal 8 cm2 electrode located in the superior vena cava. Three electrode configurations were tested: (1) single pulse, distal electrode (cathode) to proximal electrode and chest wall patch (common anode), (2) sequential 5 ms pulses with 1 ms interpulse delay, distal electrode (cathode) to proximal electrode (anode) followed by distal electrode (cathode) to chest wall patch (anode), and (3) sequential 10 ms pulses with 1 ms interpulse delay using same current pathways described for configuration 2. The lowest energies resulting in termination of AC induced ventricular fibrillation on four trials were 27.9, 26.6, and 42.3 joules respectively for configurations 1, 2, and 3. The mean energy levels were not significantly different for configurations 1 and 2, both of which were significantly lower than that for configuration 3. The lowest peak voltages terminating ventricular fibrillation on four trials were 595 +/- 176, 521 +/- 134 and 579 +/- 171 volts for configuration 1, 2, and 3. The mean voltage level for configuration 2 was significantly lower than that for configurations 1 and 3, which were not significantly different.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Delayed infection of the automatic implantable cardioverter-defibrillator. Current recognition and management.

Three cases of delayed infection of automatic implantable cardioverter-defibrillator devices without systemic manifestations are reported. Computed tomographic scan of the heart revealed fluid deep to the patch in each case. Sonication of explanted automatic implantable cardioverter-defibrillator patches facilitated the recovery of adherent microorganisms in one case. Management of this previously unrecognized problem is outlined.

Aged↗

Stratified application of the automatic implantable cardioverter defibrillator.

Since June 1983 we have developed a stratified regimen for staged implantation of the automatic implantable cardioverter defibrillator system. The protocol for management in patients who have fully recovered from sudden cardiac death is initiated with the use of standard electrophysiologic evaluation. Treatment in order of application has consisted of drugs followed by implantation of the device for patients with drug-refractory arrhythmias in whom direct cardiac surgical intervention for anatomic substrates for sudden death are absent. In surgical candidates, combinations of coronary revascularization and ablative therapy have been used to mitigrate the potential for lethal arrhythmia. Sensing and defibrillator lead systems have been placed at corrective operations to be followed later by implantation of the cardioverter defibrillator generator for either inducible or spontaneous tachyarrhythmia. This staged application has been effective in markedly reducing actual sudden cardiac death while at the same time saving on unnecessary device implantation. Morbidity of lead implantation alone remains a concern, particularly for infective complications. Additional follow-up is required to assess the validity of this approach.

Anti-Arrhythmia Agents↗

Catheter ablation: relationship of defibrillator waveform to the production of postshock ventricular tachyarrhythmias and myocardial damage.

The myocardial damage and arrhythmogenicity of percutaneous transcatheter shocks utilizing two different defibrillator waveforms (truncated exponential and damped sinusoidal) were compared. Ten dogs (33.7 +/- 3.6 kg) were studied. Five received left ventricular damped sinusoidal R-synchronous shocks during sinus rhythm and the other five received truncated exponential waveform shocks. Each dog received four energies (60, 120, 180, and 240 joules) randomly assigned to four left ventricular sites. The immediate postshock rhythms were recorded. Ventricular tachycardia occurred after 90% of the damped sinusoidal shocks compared to only 25% of the truncated exponential shocks (p less than 0.005). The animals were sacrificed 14 days later. Infarct size as determined by planimetry was not significantly different for the two waveforms. Thus intracavitary shocks utilizing a truncated exponential waveform are less arrhythmogenic than damped sinusoidal waveform shocks but produce similar morphologic changes and therefore may offer a significant safety advantage for catheter ablation procedures.

Animals↗

Relationship of left ventricular mass to defibrillation threshold for the implantable defibrillator: a combined clinical and animal study.

Defibrillation results when a critical mass of myocardium is depolarized. The relationship between echocardiographic determinations of left ventricular mass, volume, and cavity radius to wall thickness ratio and defibrillation threshold for the implantable defibrillator was examined. Ten patients with two large patch defibrillating lead systems were studied. Defibrillation threshold was determined intraoperatively as the lowest energy terminating ventricular fibrillation. Left ventricular mass, volume, and radius/posterior wall thickness ratio were calculated from two-dimensional echocardiograms. A significant correlation was found between left ventricular mass and defibrillation threshold (r = 0.78, p less than 0.01). The correlations between defibrillation threshold and left ventricular volume (r = 0.59) and radius/wall thickness ratio (r = 0.55) were not significant. Subsequently, 11 dogs undergoing defibrillation trials with a transvenous catheter and a chest wall patch were studied. Defibrillation threshold was defined as the lowest energy-terminating ventricular fibrillation (four separate attempts). Subsequently, the heart was dissected, and the left ventricle (including the septum) was weighed. The correlation between left ventricular weight and defibrillation threshold (r = 0.76) was significant (p less than 0.01). We conclude that noninvasive assessment of left ventricular mass and direct measurement of left ventricular weight are significantly correlated with defibrillation threshold and consistent with the critical mass hypothesis.

Animals↗

Nonthoracotomy internal defibrillation in dogs: threshold reduction using a subcutaneous chest wall electrode with a transvenous catheter electrode.

The efficacy of truncated exponential waveform shocks using a cardioverter-defibrillator catheter with and without a 13.9 cm2 subcutaneous thoracic patch electrode was examined in 10 pentobarbital-anesthetized dogs. The cardioverter-defibrillator catheter was positioned through the external jugular vein with the distal 4 cm2 shocking electrode located in the right ventricular apex and the 8 cm2 proximal electrode located in the superior vena cava. Four electrode configurations were tested: 1) distal electrode (cathode) to proximal electrode and chest wall patch (common anodes), 2) distal electrode (cathode) to chest wall patch (anode), 3) distal electrode (cathode) to proximal electrode (anode), and 4) chest wall patch (cathode) to proximal electrode (anode). The lowest randomized energy resulting in termination of alternating current-induced ventricular fibrillation on four trials at that energy was 20.2, 21.3, 27.4 and greater than 40 J, respectively, for configurations 1 through 4. The energy requirements for configurations 1, 2 and 3 were significantly lower than for configuration 4 (p less than 0.001). Additionally, configurations incorporating the distal electrode and the patch electrode (configurations 1 and 2) were significantly better than the catheter alone (configuration 3; p less than 0.05). There was no significant difference between configurations 1 and 2. In conclusion, the addition of a subcutaneous chest wall electrode to the cardioverter-defibrillator catheter significantly lowered energy requirements for defibrillation, suggesting that a nonthoracotomy approach for the automatic implantable cardioverter-defibrillator is feasible.

Animals↗

Catheter ablation of the atrioventricular junction and activity responsive pacing. Effect on refractory atrial fibrillation with hypertrophic cardiomyopathy.

A 50-year-old man had chronic atrial fibrillation that was refractory to conventional therapy. He was intolerant of amiodarone, but successfully managed by transcatheter atrioventricular junction ablation. Activity-initiated rate-responsive ventricular pacing resulted in a fourfold greater increase in cardiac output with exercise compared to fixed rate pacing.

Atrial Fibrillation↗

Constrictive pericarditis associated with patch electrodes of the automatic implantable cardioverter-defibrillator.

A case of constrictive pericarditis intimately involving patch electrodes of the automatic implantable cardioverter-defibrillator is described. Typical clinical and hemodynamic findings for constrictive pericarditis were noted 15 months after lead installation. Additionally, chest x-ray examination revealed a severe crumpling deformity of the patch electrodes. Thoracotomy was performed and revealed marked fibrous reaction surrounding both surfaces of each patch electrode. Histologic examination revealed fibrous tissue with multinucleated giant cells, consistent with a foreign body reaction. The patient had complete resolution of signs and symptoms of constrictive pericarditis after removal of the patch electrodes and pericardial stripping. Constrictive pericarditis from implanted patch electrodes appears to be an uncommon complication of the automatic implantable cardioverter-defibrillator and should be considered in patients with one or more patch electrodes and other signs of constrictive pericarditis.

Aged↗