A new reference method for the determination of the total CO2 concentration in biological fluids.

It appeared that a part of a measuring system recently developed for the determination of the oxygen content of blood (Dijkhuizen, P., Kwant, G. and Zijlstra, W.G. (1976) Clin. Chim. Acta 68, 79), was perfectly suitable for measuring the total CO2 content of blood, plasma or other fluids. CO2-free room air is pumped through an extraction vessel in which all the CO2 of the sample is set free by an acid reagent, and swept by the carrier gas to a titration vessel containing a BaCl2 solution. CO2 is bound as BaCO3 and the ensuing H+ titrated with an NaOH solution. The method was tested by measuring a series of Na2CO3 reference solutions. The values measured by titration amounted to 99.4 +/- 0.8% of the concentration of the reference solutions (range 10--50 mmol 1(-1). The coefficient of variation was 1.8% for 5 mmol 1(-1) solutions and 0.2% for 50 mmol 1(-1) solutions. In measuring a series of 60 blood samples the coefficient of variation as calculated from duplicate determinations was 1%.

Barium↗

Carboxyhaemoglobin. Spectrophotometric determination tested and calibrated using a new reference method for measuring carbon monoxide in blood.

The spectrophotometric determination of HbCO at lambda = 562 and 540 nm in the system HbCO/HbO2 was reinvestigated using a new reference method for measuring CO in blood. This reference method is based on the conversion of CO from HbCO into CO2 which is determined by titration. Plotting the absorbance ratio A562/A540 against the titrimetrically determined HbCO fractions of 46 blood samples demonstrated a linear relationship up to 90% HbCO and yielded more accurate values for the constants in the equation for calculating the HbCO fraction from A562/A540. The standard deviation of the differences between the spectrophotometric and the titrimetric method was 1.2% HbCO. It is shown that the influence of other haemoglobin derivatives and other possible sources of error is either negligible or can be prevented by simple precautions.

Carbon Monoxide↗

Sulfhaemoglobin. Absorption spectrum, millimolar extinction coefficient at lambda = 620 nm, and interference with the determination of haemoglobin and of haemiglobincy anide.

The spectrophotometry properties of sulfhaemoglobin (SHb) and some derivatives were investigated using an improved technique for measuring the SHb fraction induced in human blood samples. The millimolar extinction coefficient of SHb at lambda = 620 nm was found to be 20.8 (S.D. 1.48; S.E. = 0.44; n = 11). In addition it was demonstrated that the spectral changes occurring in SHb containing haemoglobin solutions upon the addition of KCN, K3Fe(CN)6 and K3Fe(CN)6 +KCN invalidate the KCN addition method for the determination of haemiglobin. The influence of clinically occurring SHb fractions on the internationally standarized total haemoglobin determination were shown to be insignificant.

Ferricyanides↗

A new reference method for the determination of the oxygen content of blood.

To be able to determine the slight differences between the theoretical and the actual O2-binding capacity of human haemoglobin, a highly accurate method has been developed for measuring the O2 content of blood samples. It is an adaptation of an established O2 determination in organic microanalysis. The bound O2 of the blood is set free by conversion of HbO2 to Hi, and the O2 stripped from the blood is converted to CO by contact with granular carbon at 1120 degrees C. The CO is then converted to CO2 using CuO at 300 degrees C and the CO2 titrated in a solution of BaCl2, using NaOH of known strength. The measuring system was checked by analysis of 36 samples of air, yielding an O2 content of 20.93 +/- 0.06%. The coefficient of variation calculated from 62 duplicate determinations of samples of human blood was 0.65%.

Autoanalysis↗