Aberration correction results in the IBM STEM instrument.

Results from the installation of aberration correction in the IBM 120 kV STEM argue that a sub-angstrom probe size has been achieved. Results and the experimental methods used to obtain them are described here. Some post-experiment processing is necessary to demonstrate the probe size of about 0.078 nm. While the promise of aberration correction is demonstrated, we remain at the very threshold of practicality, given the very stringent stability requirements.

Journal Article↗

Sub-ångstrom resolution using aberration corrected electron optics.

Following the invention of electron optics during the 1930s, lens aberrations have limited the achievable spatial resolution to about 50 times the wavelength of the imaging electrons. This situation is similar to that faced by Leeuwenhoek in the seventeenth century, whose work to improve the quality of glass lenses led directly to his discovery of the ubiquitous "animalcules" in canal water, the first hints of the cellular basis of life. The electron optical aberration problem was well understood from the start, but more than 60 years elapsed before a practical correction scheme for electron microscopy was demonstrated, and even then the remaining chromatic aberrations still limited the resolution. We report here the implementation of a computer-controlled aberration correction system in a scanning transmission electron microscope, which is less sensitive to chromatic aberration. Using this approach, we achieve an electron probe smaller than 1 A. This performance, about 20 times the electron wavelength at 120 keV energy, allows dynamic imaging of single atoms, clusters of a few atoms, and single atomic layer 'rafts' of atoms coexisting with Au islands on a carbon substrate. This technique should also allow atomic column imaging of semiconductors, for detection of single dopant atoms, using an electron beam with energy below the damage threshold for silicon.

Journal Article↗

Progress in aberration-corrected scanning transmission electron microscopy.

A new corrector of spherical aberration (C(S)) for a dedicated scanning transmission electron microscope (STEM) is described and its results are presented. The corrector uses strong octupoles and increases C(C) by only 0.2 mm relative to the uncorrected microscope. Its overall stability is greatly improved compared to our previous design. It has achieved a point-to-point resolution of 1.23 A in high-angle annular dark field images at 100 kV. It has also increased the current available in a 1.3 A-sized probe by about a factor of ten compared to existing STEMs. Its operation is greatly assisted by newly developed autotuning software which measures all the aberration coefficients up to fifth order in less than one minute. We conclude by discussing the present limits of aberration-corrected STEM, and likely future developments.

Journal Article↗

Preliminary study of electron-energy-loss spectra of YBa2Cu3O7-delta.

We have obtained the electron-energy-loss spectra below 1,000 eV for YBa2Cu3O7-delta. The spectra show contributions from all elemental constituents, although the Y-signal is very weak owing to its small concentration. The low-loss region and the Ba-core losses are very similar to those obtained for BaO. The Cu absorption is similar to that seen in CuO with minor differences relating to Cu concentration and anisotropy. The oxygen 1s absorption has a shape that is quite different from that obtained in CuO and shows striking orientational anisotropy. Radiation damage in the microscope is a problem and leads to changes in the shape of the oxygen edge.

Electric Conductivity↗

The direct determination of magnetic domain wall profiles by differential phase contrast electron microscopy.

A new technique for the quantitative investigation of magnetic structures in ferromagnetic thin films is proposed. Unlike previous techniques the detected signal is simply related to the magnetic induction in the film, and as such the direct determination of domain wall profiles is possible. The technique utilizes a differential phase contrast mode of scanning transmission electron microscopy in which the normal bright field detector is replaced by a split-detector lying symmetrically about the optic axis of the system. The difference signal from the two halves of the detector provides the required magnetic information. Analysis of the image formation mechanism shows that, using a commercially available scanning transmission electron microscope equipped with a field emission gun, wall profiles should be obtainable directly from most structures of interest in Lorentz microscopy. Furthermore, signal-to-noise considerations indicate that these results can be obtained in acceptably short recording times. Finally, experimental results using both polycrystalline and single crystal specimens are presented, which confirm the theoretical predictions.