Rapid dual-injection single-scan 13N-ammonia PET for quantification of rest and stress myocardial blood flows.

Quantification of myocardial blood flows at rest and stress using 13N-ammonia PET is an established method; however, current techniques require a waiting period of about 1 h between scans. The objective of this study was to test a rapid dual-injection single-scan approach, where 13N-ammonia injections are administered 10 min apart during rest and adenosine stress. Dynamic PET data were acquired in six human subjects using imaging protocols that provided separate single-injection scans as gold standards. Rest and stress data were combined to emulate rapid dual-injection data so that the underlying activity from each injection was known exactly. Regional blood flow estimates were computed from the dual-injection data using two methods: background subtraction and combined modelling. The rapid dual-injection approach provided blood flow estimates very similar to the conventional single-injection standards. Rest blood flow estimates were affected very little by the dual-injection approach, and stress estimates correlated strongly with separate single-injection values (r=0.998, mean absolute difference=0.06 ml min-1 g-1). An actual rapid dual-injection scan was successfully acquired in one subject and further demonstrates feasibility of the method. This study with a limited dataset demonstrates that blood flow quantification can be obtained in only 20 min by the rapid dual-injection approach with accuracy similar to that of conventional separate rest and stress scans. The rapid dual-injection approach merits further development and additional evaluation for potential clinical use.

Ammonia↗

Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography: comparison with static thallium-201 in a canine model.

UNLABELLED: Di Bella EVR, Ross SG, Kadrmas DJ, et al. Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography: Comparison with static thallium-201 in a canine model. Invest Radiol 2001;36:178-185. RATIONALE AND OBJECTIVES: A compartmental modeling approach to deriving kinetic parameters from a time series of single-photon emission computed tomography (SPECT) images of technetium-99m-labeled (99mTc-) teboroxime may have value for semiquantitative assessment of myocardial perfusion. This study investigated the value of the kinetic parameters derived from a two-compartment model of 99mTc-teboroxime for measuring myocardial perfusion and compared it with static thallium-201 (201Tl) uptake and microsphere-measured blood flow in dogs. METHODS: Experiments were successfully conducted in 9 of 11 open-chest dogs. During adenosine stress, a single complete set of projections of 201Tl uptake was acquired. 99mTc-teboroxime was then injected during adenosine stress, and a complete set of projections was acquired every 5.7 seconds for 17 minutes. Resting studies were performed on 4 of the animals. All of the projection sets were reconstructed with an iterative algorithm and incorporated corrections for attenuation and the geometric response of the collimators. Regional kinetic parameters (washin and washout) were determined semiautomatically from the time series of reconstructed 99mTc-teboroxime images and registered with microsphere data. Regional washin estimates were compared with 201Tl intensities and myocardial blood flows determined from microspheres. RESULTS: Optimally scaled 99mTc-teboroxime washin parameters and 201Tl uptakes were correlated with microsphere-determined blood flows (r = 0.91, y = 0. 99x + 0.01, and r = 0.92, y = 0.88x + 0.28, respectively). In six of the studies, the left anterior descending coronary artery was occluded, and stress occluded-to-normal (O/N) ratios were calculated. The O/N ratios were 0.32 +/- 0.17 as determined from microspheres injected with 201Tl and 0.38 +/- 0.29 from microspheres injected with 99mTc-teboroxime (P = NS). The O/N ratios were 0.48 +/- 0.16 for static 201Tl uptake and 0.27 +/- 0.21 for 99mTc-teboroxime washin (P < 0.05). CONCLUSIONS: Both 201Tl uptake and 99mTc-teboroxime kinetic parameters were well correlated with flow. The 99mTc-teboroxime washin parameters offer semiquantitative flow values and provide greater defect contrast than can be obtained with 201Tl uptake values.

Animals↗

Feasibility of dual-isotope coincidence/single-photon imaging of the myocardium.

UNLABELLED: Hybrid PET scanners offer the possibility of obtaining myocardial viability information from coincidence imaging of the positron emitter (18)F-FDG and perfusion measurements from a single-photon tracer-potentially simultaneously. This new approach is less costly and more readily available than dedicated PET and offers potential for improved FDG resolution and sensitivity compared with SPECT with 511-keV collimators. Simultaneous imaging of the coincidence and single-photon events offers the further advantages of automatic image registration and reduced imaging time. However, the feasibility of simultaneous coincidence/single-photon imaging or even immediately sequential imaging is unknown. In this study, the potential of using standard low-energy high-resolution (LEHR) collimators with hybrid PET to obtain coincidence and SPECT data was assessed. METHODS: Phantom and human studies were performed to investigate the effect of LEHR collimators on FDG coincidence imaging with a hybrid PET system, the effect of the presence of (99m)Tc during FDG coincidence imaging with LEHR collimators, and the effect of the presence of FDG during (99m)Tc SPECT imaging. RESULTS: FDG images were somewhat degraded (a measure of myocardial nonuniformity increased 10%) with LEHR collimators. With 148 MBq (4 mCi) (99m)Tc present during FDG imaging of a phantom, image quality was maintained and the number of detected coincidences changed by <5%. With (99m)Tc/(18)F whole-body ratios of 7:1, crosstalk from (18)F photons accounted for the majority of counts in the (99m)Tc SPECT images and resulted in severe artifacts. The artifacts were decreased with a simple crosstalk correction scheme but remained problematic. CONCLUSION: (99m)Tc/(18)F ratios of at least 9:1 and state-of-the-art reconstruction and crosstalk correction are likely to be required to perform immediately sequential coincidence/single-photon imaging of the myocardium with clinically useful results. Additional challenges remain before simultaneous imaging of coincidence events and single photons can be realized in practice.

Feasibility Studies↗

A three-dimensional ray-driven attenuation, scatter and geometric response correction technique for SPECT in inhomogeneous media.

The qualitative and quantitative accuracy of SPECT images is degraded by physical factors of attenuation, Compton scatter and spatially varying collimator geometric response. This paper presents a 3D ray-tracing technique for modelling attenuation, scatter and geometric response for SPECT imaging in an inhomogeneous attenuating medium. The model is incorporated into a three-dimensional projector-backprojector and used with the maximum-likelihood expectation-maximization algorithm for reconstruction of parallel-beam data. A transmission map is used to define the inhomogeneous attenuating and scattering object being imaged. The attenuation map defines the probability of photon attenuation between the source and the scattering site, the scattering angle at the scattering site and the probability of attenuation of the scattered photon between the scattering site and the detector. The probability of a photon being scattered through a given angle and being detected in the emission energy window is approximated using a Gaussian function. The parameters of this Gaussian function are determined using physical measurements of parallel-beam scatter line spread functions from a non-uniformly attenuating phantom. The 3D ray-tracing scatter projector-backprojector produces the scatter and primary components. Then, a 3D ray-tracing projector-backprojector is used to model the geometric response of the collimator. From Monte Carlo and physical phantom experiments, it is shown that the best results are obtained by simultaneously correcting attenuation, scatter and geometric response, compared with results obtained with only one or two of the three corrections. It is also shown that a 3D scatter model is more accurate than a 2D model. A transmission map is useful for obtaining measurements of attenuation and scatter in SPECT data, which can be used together with a model of the geometric response of the collimator to obtain corrected images with quantitative and diagnostically accurate information.

Algorithms↗

Effects of carvedilol on right ventricular function in chronic heart failure.

This study investigated the effects of carvedilol on right ventricular (RV) volume and systolic function in chronic heart failure patients. Carvedilol treatment resulted in a significant improvement of RV ejection fraction and systolic performance, which paralleled the improvement of systolic function demonstrated in the left ventricle.

Adrenergic beta-Antagonists↗

Iterative reconstruction of fluorine-18 SPECT using geometric point response correction.

UNLABELLED: This article demonstrates resolution recovery in 18F SPECT image reconstruction by using an iterative algorithm that corrects for the system geometric response. METHODS: Patient and phantom studies were performed using a Picker PRISM 3000 three-detector SPECT system (Picker International, Inc., Cleveland, OH) to image 18F with 511 keV collimators. A measured point response function of the imaging system was used in an iterative reconstruction algorithm in which the projector and backprojector modeled the system point response function by using an efficient layer-by-layer blurring technique. The blurring function was a five-element kernel in the shape of a cross. The iterative reconstruction algorithm was an ordered-subset maximum-likelihood expectation maximization algorithm. RESULTS: The iterative reconstruction algorithm with geometric response correction showed an improvement in resolution over the filtered backprojection reconstruction and the iterative reconstruction without correction. CONCLUSION: The proposed iterative reconstruction algorithm with geometric response correction is efficient and effective with significant resolution recovery.

Aged↗

Effects of carvedilol on systolic and diastolic left ventricular performance in idiopathic dilated cardiomyopathy or ischemic cardiomyopathy.

Recent evidence has shown that improvement in left ventricular (LV) systolic function in patients with New York Heart Association class II to III heart failure occurs with beta-adrenergic blocking agents. However the specific effects on LV diastolic function have been subjected to only limited examination. This study investigated the effects of the combined beta blocker/vasodilator, carvedilol, on systolic and diastolic LV performance in dilated cardiomyopathy. Thirty-six patients with New York Heart Association II to III heart failure and LV ejection fraction < or = 0.35 were entered into either arm of this placebo-controlled, double-blind 4-month trial. Twenty-one subjects were entered into the carvedilol treatment arm and 15 patients were entered into the placebo arm in a 3:2 ratio. Carvedilol therapy resulted in a significant improvement in LV ejection fraction, from 0.22 +/- 0.02 to 0.30 +/- 0.02 when compared with the placebo group (0.19 +/- 0.02 to 0.21 +/- 0.02 at baseline and after 4 months of therapy, respectively; p = 0.0001). However, no significant change in radionuclide parameters of LV diastolic function, including peak filling rate or time to peak filling rate, was observed. LV end-diastolic volume index did not change with carvedilol therapy, whereas end-diastolic volume index increased in the placebo group, although the difference between groups at 4 months was significant (p = 0.02). In conjunction with these changes, end-systolic volume index was smaller at 4 months after carvedilol treatment compared with that of the placebo group (p = 0.04). Thus, these results demonstrate that in moderate chronic heart failure, systolic LV performance improves but diastolic LV function does not improve when compared with placebo after treatment with carvedilol.

Adrenergic beta-Antagonists↗

Use of computer conferencing to allow view box-style teaching sessions with residents at outlying hospitals.

RATIONALE AND OBJECTIVES: Health care reform is placing new pressures on radiology faculty members to use their time more efficiently. We implemented a computer conferencing technique that allows one faculty member to perform a simultaneous view box-style teaching session with residents at local and outlying hospitals. METHODS: The system simultaneously displays digital images on computer screens at the local and outlying hospitals; an on-screen pen allows the instructor or the participants to point to findings on the images. Audio is provided either by a telephone conference call using speakerphones or over the wide-area network using microphones and speakers built into the computers. RESULTS: The technique has been in use for 1 year. A survey of the faculty and residents indicate that computer conferencing is equivalent to traditional face-to-face teaching sessions at the view box. CONCLUSION: Computer conferencing is possible and accepted. The technique is low-cost, using generic computers that are part of the picture archiving and communication system at both hospitals, and relatively inexpensive conferencing software.

Computer Communication Networks↗

Gastric emptying response to variable oral erythromycin dosing in diabetic gastroparesis.

Intravenous erythromycin has been shown to improve gastric emptying in diabetic gastroparesis. Oral erythromycin also accelerates gastric emptying, but to a lesser degree. To determine if this is a dose-dependent phenomenon, gastric emptying was measured in 10 insulin-requiring diabetic patients with gastroparesis after administration of either 250 mg or 1000 mg of erythromycin or placebo. The drugs were orally administered in a randomized, double-blind fashion 30 min prior to ingestion of a meal containing [99mTc]-sulfur colloid-labeled beef stew and [111In]DTPA-labeled orange juice. Anterior and posterior gastric images were recorded for 3 hr at 15-min intervals using an externally positioned gamma camera. The results demonstrated that both doses of oral erythromycin significantly improved solid-phase gastric emptying. The mean half-emptying time of solids was decreased from 151 +/- 40 min with placebo to 58 +/- 10 min and 40 +/- 9 min with 250 mg and 1000 mg of erythromycin, respectively. However, a dose-dependent relationship was not demonstrated with the two doses of erythromycin employed. These results suggest that for most patients with diabetic gastroparesis, a single 250-mg dose of erythromycin will significantly improve gastric emptying. It is possible that a dose-dependent relationship will be demonstrated with doses of erythromycin less than 250 mg.

Administration, Oral↗

A transmission-map-based scatter correction technique for SPECT in inhomogeneous media.

In this paper a method of modeling the distribution of scattered events in emission projection data is developed and applied. This method is based on the use of a transmission map to define the inhomogeneous scattering object. The key point is the use of the set of line integrals calculated as part of the attenuation correction technique, as the basis of a model of the distribution of scattered events. The probability of a photon being scattered through a given angle and being detected in the emission energy window is approximated using a Gaussian function. The parameters of this Gaussian are determined using Monte Carlo generated parallel-beam scatter line spread functions from a nonuniformly attenuating phantom. The model is incorporated into a two-dimensional projector-backprojector and used with the Expectation-Maximization-Maximum-Likelihood algorithm for the reconstruction of fan-beam phantom data. The correction is shown to perform well for a phantom that varies slowly in the axial direction. For the more clinically realistic situation of a torso phantom, the method produces improvements in terms of blood pool to myocardium contrast, but does not restore the contrast to the level exhibited in a reconstruction from "scatter free" data.

Humans↗

Biodistribution and dosimetry of indium-111-polyclonal IgG in normal subjects.

UNLABELLED: Indium-111-polyclonal IgG is a new imaging agent of infection and inflammation that has been developed as a possible replacement for radiolabeled leukocytes. We undertook a study to determine the safety, biodistribution and dosimetry of the agent in normal subjects. METHODS: Twelve normal male volunteers with an average age of 34 yr (range 21-55 yr) were studied. Each was injected with 1.22-1.47 mCi 111In-labeled polyclonal IgG; digital whole-body images, in addition to blood, urine and fecal samples, were obtained immediately after injection and at 6, 24, 48, 72, 96 and 120 hr. Whole-body counts, as well as individual organ data obtained by outlining regions of interest, were measured. Blood, urine and fecal counting were done in a well counter and compared to known standards; dosimetry calculations were performed with the MIRD technique. RESULTS: The mean whole-blood activity had a two-phase disappearance curve: the T1/2I was 11.4 hr (61.1%) and the T1/2II was 112.5 hr (38%). Twelve percent of the dose was excreted in the urine and 1.14% in the feces. Skeletal muscle had the highest percentage of uptake, followed by the bone marrow, liver and lungs; the spleen showed less than 1% uptake. Activity in the lungs varied with time, falling by 37% after 18 hr and by 68% after 72 hr. Dosimetry calculations indicated that the highest absorbed dose was to the liver (1.42 rad/mCi) followed by the testes (1.23 rad/mCi) and red marrow (0.976 rad/mCi). The total-body dose was 0.467 rad/mCi, with an effective dose equivalent of 790.84 mrem. CONCLUSION: The biodistribution of 111In IgG is similar to that of 99mTc-HMPAO-labeled leukocytes. Activity in the liver, kidneys and GI tract may make evaluation of infection in these regions difficult. The dosimetry data indicate that adequate doses can be administered for clinical imaging without exposing the patient to excessive radiation.

Adult↗

Redirection of client/server relationship of X Window system as a simple, low-cost, departmental picture archiving and communication system solution for nuclear medicine.

Picture archiving and communication systems (PACS) offer significant advantages over current film-management techniques. However, PACS are complex and expensive, factors that have limited their entry into the radiology and nuclear medicine communities. We present a simple, low-cost PACS solution that allows viewing of images from different computer systems by redirection of the X Window system. In this technique, multiple copies of the imaging software are remotely opened from generic UNIX workstations interfaced to the main computer system via Transmission Control Protocol/Internet Protocol over Ethernet. The X Window system that provides the windowing system for the main computer is redirected to the workstations' displays. With this technique, viewing and processing of images on a remote station is virtually identical to working at the main computer's console. The technique requires that the commercial imaging system's hardware, operating system, and imaging software support multiuser multitasking and the execution of multiple copies of its imaging software, and that they use X Windows as the graphical system. Advantages of the technique include low cost, ease of maintenance, ease of interconnecting different types of computers, the capacity to view images regardless of file format, and the capacity to both view and process images. The latter is a necessity for modalities such as nuclear medicine. A disadvantage of the technique is that the number of nodes that can be supported is limited.

Computer Communication Networks↗

Application of convergent-beam collimation and simultaneous transmission emission tomography to cardiac single-photon emission computed tomography.

Single-photon emission computed tomography (SPECT) is the most commonly performed imaging technique for perfusion studies of the heart and brain. However, these organs are much smaller than the crystal surface of gamma cameras. SPECT sensitivity and resolution can be improved by using fan- and cone-beam collimators to magnify the image of these organs over a larger portion of the crystal face. Special orbits and reconstruction algorithms must be used with convergent-beam acquisitions to prevent image distortion. Differential attenuation of source activity in the chest is one of the most vexing problems in cardiac SPECT, especially with Thallium-201. Multi-headed cameras equipped with convergent-beam collimators allow a transmission image to be obtained at the same time as emission images. Applying a transmission map of the chest attenuation values to the emission images produces a truer picture of source distribution in the heart. This article reviews the technical problems associated with convergent-beam geometry and simultaneous transmission emission tomography SPECT imaging of the heart.

Algorithms↗

Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model.

UNLABELLED: The tomographic utility of 99mTc-labeled teboroxime has been limited because of its fast washout from the heart, which requires rapid data acquisitions that have not been feasible until the recent development of multidetector SPECT systems. METHODS: Using a three-detector SPECT system to acquire dynamic tomographic data every 10.2 sec, we investigated the potential of modeling the kinetics of teboroxime to develop a sensitive and quantitative measure of cardiac perfusion. Seven studies were performed on four dogs; in three of the studies the LAD artery was occluded. The three-dimensional activity distributions were reconstructed and were corrected for attenuation using a transmission scan. Time-activity curves from the blood and tissue were fit to a two-compartment model with two-way exchange. RESULTS: Performing attenuation correction during the reconstruction process affected the washin parameter k21 significantly (p < 0.0001). The washin parameter k21 also decreased significantly (p < 0.002) when the LAD was occluded. CONCLUSIONS: The results indicate that the washin of teboroxime in myocardial tissue (k21) measured using dynamic SPECT imaging and kinetic modeling is an indicator of myocardial blood flow.

Algorithms↗

Image analysis and categorization of ventilation-perfusion scans for the diagnosis of pulmonary embolism using an expert system.

UNLABELLED: An expert system was developed that interprets ventilation-perfusion lung scans. The use of such scans for suspected pulmonary embolism is ideal for computer-assisted diagnosis by expert systems. The data are digital, only a single disease entity is diagnosed or excluded, and well-established diagnostic criteria already exist for visual interpretation that can be easily integrated into an expert system. METHODS: This expert system is divided into two modules. The first module is responsible for image analysis. Analysis was performed on the eight standard perfusion images and on single-breath, equilibrium and 3-min washout ventilation images. Each image was analyzed for the presence of regional perfusion or ventilation defects, as determined by pixel values that fell 2.2 s.d. below the mean (or above the mean in the case of washout images) compared with a database of normal studies. The defect size, segment involved and number of defects were determined. Ventilation and perfusion images were then compared to determine whether defects were matched or mismatched. The second program module applied the modified Biello's criteria to the data and categorized the scan as normal to low, intermediate or high probability. RESULTS: A total of 80 patients were prospectively studied. An 81% (65 of 80) correlation was obtained when the results of the expert system were compared with visual interpretations made by three experienced nuclear medicine physicians. CONCLUSION: This study shows that the interpretation of ventilation-perfusion lung scans by an expert system is possible. The technique holds the promise of reducing interobserver variability and assisting less experienced observers in the interpretation of such scans.

Expert Systems↗

The efficacy of indium-111-polyclonal IgG for the detection of infection and inflammation.

UNLABELLED: The purpose of this study was to determine the efficacy of 111In-polyclonal immunoglobulin (IgG) for the diagnosis of infection or inflammation. METHODS: Fifty-three patients with suspected infection were prospectively studied. Each underwent an 111In-polyclonal IgG study; biopsy, surgery, additional nuclear medicine scans and radiographic studies were used to confirm the IgG scan results. RESULTS: The polyclonal IgG scan had a sensitivity of 97.9% and a specificity of 94% for infection or inflammation. When only infection or severe inflammation such as bowel infarction was considered, the sensitivity remained the same but the specificity fell to 83%. Chronic infections were detected equally as well as acute infections. Antibiotics, steroids, anti-inflammatory agents, diabetes and diminished renal function did not affect scan sensitivity. There were no adverse reactions to the radiopharmaceutical. Three patients underwent extended imaging. Their scans stayed positive for an average of 8 days. Three patients treated for infection had their scans turn negative on repeat study, confirming the efficacy of their antibiotic therapy. CONCLUSION: Indium-111-polyclonal IgG is an effective imaging agent of infection and/or inflammation that is useful in a variety of infections and in severe inflammatory diseases. The ease of preparation and safety make it an attractive alternative to labeled leukocytes.

Adult↗

The use of computer-assisted diagnosis in cardiac perfusion nuclear medicine studies: a review (Part 2).

Computer-assisted diagnosis (CAID) is commonly used to evaluate cardiac nuclear medicine studies such as thallium perfusion scans. Part I of this series (Journal of Digital Imaging, Vol 5, No 4, pp 209-222) reviewed the basic theory underlying CAID in nuclear medicine and its use in planar thallium imaging. This review discusses the application of CAID to SPECT perfusion studies.

Artifacts↗

The use of computer-assisted diagnosis in cardiac perfusion nuclear medicine studies: a review (Part 3)

Computer-assisted diagnosis (CAID) is commonly used to evaluate cardiac nuclear medicine studies such as thallium perfusion scans. Part 1 of this series (Journal of Digital Imaging, 5:209-222, 1992) reviewed the basic theory underlying CAID in nuclear medicine and its use in planar thallium imaging. Part 2 discussed the application of CAID to SPECT perfusion studies (Journal of Digital Imaging, 6:1-15, 1993). This article reviews new variations of CAID programs for SPECT imaging and the application of expert systems and neural networks to CAID of nuclear medicine perfusion studies.

Algorithms↗