PubMed Health⌕ Search

Biomedical subjects

P E Vardas

Publications and source records attributed to P E Vardas.

At least 19 recordsLinked to original sources

Impedance cardiography derived cardiac output in hemodialysis patients: a study of reproducibility and comparison with echocardiography.

BACKGROUND: Hemodialysis patients experience a variety of hemodynamic abnormalities that contribute to cardiovascular disease mortality which is the leading cause of death in these patients. Impedance cardiography has been utilized in order to monitor cardiac hemodynamics with lower cost and inconvenience, but it has not been appropriately validated in the hemodialysis population. AIM: We repeatedly used impedance cardiography to assess short- (48 hours) and long-term (15 days) reproducibility of cardiac output measurements and we compared baseline impedance cardiography measurements with echocardiographic measurements. PATIENTS AND METHODS: We studied 109 stable hemodialysis patients, aged 59.70 +/- 11.97 years being on hemodialysis for 67.59 +/- 40.15 months, on a non-dialysis day. Cardiac output was obtained with the BioZ impedance cardiography system (Cardiodynamics, San Diego, Ca, USA). Baseline echocardiography was performed using a Hewlett-Packard Sonos 2500 (Andover, Mass., USA). RESULTS: The values of impedance cardiography derived cardiac output were 5.28 +/- 0.79, 5.27 +/- 0.75 and 5.25 +/- 0.74 l/min at baseline (107 patients), 48 hours (107 patients) and 15 days (98 patients) respectively, showing high reproducibility. Bland and Altman analysis estimated that bias at 48 hours and at 15 days were: -0.013 (95% confidence intervals = -0.045 to 0.019) and 0.028, (95% confidence intervals = -0.044 to 0.101), respectively. In addition baseline impedance cardiography derived cardiac output was significantly correlated with the echocardiographic derived cardiac output (r = 0.9, p < 0.0001). CONCLUSION: Impedance cardiography is a simple non invasive technique for cardiac output estimation in hemodialysis patients which has high reproducibility when performed under controlled conditions, and is closely correlated with echocardiographic measurements of cardiac output.

Aged↗

Alteration of proximal aorta biophysical properties in patients with end stage renal disease.

OBJECTIVE: To present a novel, non-invasive echocardiographic application to assess the structural and functional properties of the complex composition of the proximal aorta in patients with end stage renal disease (ESRD). METHODS: 71 haemodialysis patients (mean (SD) age 61.3 (9.3) years, dialysis duration 79.2 (51.6) months) and 62 age matched controls were studied. From the suprasternal view, the distance between ascending and descending aorta was measured with two dimensional ultrasound. The aortic flow wave transit time was measured with pulsed wave Doppler. M mode echocardiography, with simultaneous blood pressure estimates, was used to assess the diameters of the aortic annulus and of the ascending aorta. Pulse pressure, pulse wave velocity (PWV), pressure strain elastic modulus, characteristic impedance, and beta index were calculated. RESULTS: Patients had increased pulse pressure (68.0 (7.2) v 51.4 (5.0) mm Hg, p < 0.001), PWV (6.1 (1.1) v 3.9 (0.6) m/s, p < 0.001), characteristic impedance (174 (58) v 111 (31) m/s.cm2, p < 0.001), pressure strain elastic modulus (872 (254) v 541 (140) mm Hg, p < 0.001), and beta index (8.9 (3.4) v 5.5 (1.4), p < 0.001) compared with controls. In patients PWV was correlated with age and time on haemodialysis (r = 0.44, p < 0.001, and r = 0.51, p < 0.001, respectively). CONCLUSION: A novel application of duplex ultrasound of the proximal aorta showed that patients with ESRD have impaired proximal aortic function compared with controls. The data indicate that these non-invasive measurements can be used to describe status and change in aortic biophysical properties and may be used as a marker for cardiovascular disease risk.

Aorta↗

Sensing issues related to the clinical use of implantable loop recorders.

AIMS: The newer insertable loop recorder device (Reveal Plus 9526, Medtronic Inc, Minneapolis MN, U.S.A.) is equipped with auto-activation capabilities. In this study we investigated whether the new device encounters sensitivity problems in the form of oversensing or undersensing. We also tested whether body position changes influence the sensed electrogram's amplitude, therefore affecting the device's autosensing ability. METHODS AND RESULTS: We enrolled 32 patients aged 58.1+/-11.7 years with a loop recorder implanted either in the left parasternal or in the heart's apex area, to investigate undiagnosed syncopal episodes after initial assessment. During the follow-up period (5.7+/-2.7 months), that began 6 months after the device implantation, we analysed 284 auto-recorded episodes (103 undersensed and 181 correctly sensed). No oversensing episodes were recorded. THE RECORDED QRS amplitude in five different body positions: supine, left and right lateral, sitting and standing was measured. No statistically significant changes were observed in the different postures. Even when patients were divided into subgroups according to implant site or the occurrence of undersensing episodes, no significant inter- or intra-group differences of the sensed electrogram were observed. CONCLUSION: Undoubtedly this device is the current gold standard for the diagnosis of unexplained syncope. In the population we studied though, the device faced undersensing problems. Consequently, the device should be equipped with more advanced software for QRS morphology recognition, to improve the diagnostic accuracy of the recorder.

Adult↗

Autonomic imbalance during the day in patients with inflammatory bowel disease in remission. Evidence from spectral analysis of heart rate variability over 24 hours.

BACKGROUND: Autonomic function in inflammatory bowel disease has not yet been studied by means of analysis of 24-hour heart rate variability. AIM: To measure heart rate variability in inflammatory bowel disease patients in remission. PATIENTS AND METHODS: Study population comprised 27 patients with inflammatory bowel disease in remission and 28 healthy, sex- and age-matched controls. Two frequency ranges were analysed: low frequency (0.06-0.15 Hz) and high frequency (0.15-0.40 Hz). RESULTS: Mean values of low frequency and low frequency/high frequency ratio were lower in patients than in controls (p < 0.001). High frequency in patients tended to be higher than in controls (p = 0.09). The only factor that had a marginal effect on heart rate variability indexes was age. In high frequency, there was a significant time effect (p = 0.001) for both groups. There was also a significant time effect in low frequency/high frequency ratio in both groups (p < 0.001). During daytime, the mean values in low frequency/high frequency ratio were lower in patients than in controls (p < 0.001). CONCLUSIONS: There is a shift in the autonomic balance in patients with inflammatory bowel disease in remission towards a condition of relative parasympathetic predominance, which, in the first place, reflects a sympathetic pullback. This imbalance has a circadian rhythm and it is more pronounced during the day.

Anti-Inflammatory Agents, Non-Steroidal↗

Effect of acute atrial fibrillation on phasic coronary blood flow pattern and flow reserve in humans.

AIMS: To assess the effect of experimentally induced atrial fibrillation on coronary flow in humans. METHODS AND RESULTS: In 16 patients (10 men, mean age 43+/-13 years) with normal coronary vessels, baseline and hyperaemic blood pressure and Doppler phasic coronary flow velocity were measured, using a 0.014 inch intracoronary Doppler flow wire, during sinus rhythm, experimentally induced atrial fibrillation, and right atrial pacing at a similar heart rate to that during atrial fibrillation. Coronary flow velocity integral per minute increased significantly during both right atrial pacing and atrial fibrillation compared to sinus rhythm, but during right atrial pacing the increase was greater (85+/-43% vs 52+/-25%, P<0.001). This difference persisted even after correction for the product of heart rate and blood pressure (1.15+/-0.51 vs 0.97+/-0.46, respectively, P<0.02). In a further 12 paced patients (seven men, mean age 54+/-10 years) with complete atrioventricular block the induction of atrial fibrillation (atrial fibrillation with regular RR interval) caused no significant changes in coronary flow velocity variables. CONCLUSIONS: Acute atrial fibrillation in humans causes an increase in coronary flow that is, however, insufficient to compensate for the augmented myocardial oxygen demand, mainly because of the irregularity in the ventricular rhythm that exists during atrial fibrillation.

Acute Disease↗

Implantable loop recorder undersensing mimicking complete heart block.

The newer implantable loop recorders recently introduced (Reveal Plus. Medtronic Inc, Minneapolis, MN, U.S.A.). equipped with auto activation capabilities, are expected to expand our diagnostic abilities in the investigation of syncopal episodes. The case presented here is that of a man with pre-syncopal and syncopal episodes, without organic heart disease, in whom the device was auto-activated due to undersensing and the recorded strip imitated complete heart block. Increased attention should be given by the interpreter of the device's recordings to avoid false positive diagnoses that might lead to serious therapeutic actions.

Aged↗

Assessment of myocardial adrenergic innervation in patients with sick sinus syndrome: effect of asynchronous ventricular activation from ventricular apical stimulation.

OBJECTIVE: To investigate ventricular sympathetic innervation in patients with sick sinus syndrome and to detect regional deterioration of adrenergic innervation caused by asynchronous ventricular activation from right ventricular pacing. DESIGN: Prospective controlled study. SETTING: Tertiary cardiac referral centre. PATIENTS: 22 patients with sick sinus syndrome and indications for permanent dual chamber pacing; 20 healthy individuals as controls. INTERVENTIONS: All patients underwent myocardial imaging with planar and single photon emission computed tomography (SPECT) after an intravenous infusion of 5 mCi 123I-meta-iodobenzylguanidine (123I-MIBG) before and after pacemaker implantation. A SPECT thallium201 myocardial study was done during the same week as the 123I-MIBG study in all patients. MAIN OUTCOME MEASURES: The heart to mediastinum (H/M) ratio and washout rate were calculated during the 123I-MIBG study to assess the global cardiac sympathetic activity; the aim of the SPECT study was to investigate the regional distribution of adrenergic innervation. RESULTS: The H/M ratio was significantly smaller in the patients with sick sinus syndrome than in the controls (p < 0.001). In sick sinus syndrome there were regional adrenergic innervation defects, mostly in the inferior and apical walls. After a medium term pacing period, a redistribution of 123I-MIBG uptake was detected, with deterioration of adrenergic innervation in the inferior, apical, and posterior walls. The thallium201 myocardial perfusion study showed no change after three months of permanent pacing. CONCLUSIONS: Patients with sick sinus syndrome have global and regional disturbances of the adrenergic innervation of the left ventricular myocardium. These seem to deteriorate as a result of asynchronous electrical activation. The clinical significance of this finding requires further investigation.

3-Iodobenzylguanidine↗

Myocardial perfusion in patients with permanent ventricular pacing and normal coronary arteries.

OBJECTIVES: The purposes of this study were to test the specificity of dipyridamole myocardial perfusion scintigraphy in patients with permanent ventricular pacing (PVP) and to evaluate coronary blood flow and reserve in these patients. BACKGROUND: Permanent ventricular pacing is associated with exercise perfusion defects on myocardial scintigraphy in the absence of coronary artery disease (CAD). On the basis of studies in patients with left bundle brunch block, coronary vasodilation with dipyridamole has been proposed as an alternative to exercise testing for detecting CAD in paced patients, but this approach has never been tested. METHODS: Fourteen patients with a PVP and normal coronary arteries underwent stress thallium-201 scintigraphy and cardiac catheterization. In these patients and in eight control subjects, coronary flow velocities were measured in the left anterior descending coronary artery (LAD) and in the dominant coronary artery before and after adenosine administration. RESULTS: In the paced patients, coronary flow velocities in the LAD and in the dominant coronary artery were significantly lower than those in the control subjects. In addition, seven patients showed perfusion defects on dipyridamole thallium-201 single-photon emission computed tomography, with a specificity of 50% for this test. The defect-related artery in these patients had lower coronary flow reserve (2.6 +/- 0.5) as compared with those without perfusion defects (3.9 +/- 1.0, p < 0.05) or the control group (3.5 +/- 0.5, p < 0.05). CONCLUSIONS: Permanent ventricular pacing is associated with alterations in regional myocardial perfusion. Furthermore, abnormalities of microvascular flow, as indicated by reduced coronary flow reserve in the defect-related artery, are at least partially responsible for the uncertain specificity of dipyridamole myocardial perfusion scintigraphy.

Aged↗

Electrical storm due to amiodarone induced thyrotoxicosis in a young adult with dilated cardiomyopathy: thyroidectomy as the treatment of choice.

For a patient with idiopathic dilated cardiomyopathy, an implantable defibrillator, and amiodarone induced thyrotoxicosis associated with ventricular fibrillation storm. Medical therapy was ineffective. Thyroidectomy resulted in immediate control of the arrhythmia and permitted reinitiation of amiodarone. At 18-month follow-up, the patient remained euthyroid on amiodarone and ventricular arrhythmia free.

Adult↗

Sinus pacemaker function after cardioversion of chronic atrial fibrillation: is sinus node remodeling related with recurrence?

INTRODUCTION: The objective of this study was to investigate the temporal changes in sinus node function in postcardioversion chronic atrial fibrillation (AF) patients and their possible relation with the recurrence rates of AF. METHODS AND RESULTS: In 37 chronic AF patients, internally cardioverted to sinus rhythm, corrected sinus node recovery time (CSNRT), and the pattern of corrected return cycle lengths were assessed 5 to 20 minutes and 24 hours after conversion. The last 20 consecutive patients also were evaluated after autonomic blockade. Twenty subjects with normal atrial structure and no history of AF served as the control group. Patients were followed-up for 1 month for recurrence, and the density of supraventricular ectopic beats per hour was obtained during the first 24 hours after conversion. Fifteen patients (40.5%) relapsed during follow-up. CSNRT values at 600 msec (371 +/- 182 msec) and 500 ms (445 +/- 338 msec) were significantly higher than those of control subjects (278 +/- 157 msec, P = 0.050, and 279 +/- 130 msec, P = 0.037, respectively). Significant temporal changes in CSNRT also were observed during the first 24 hours after conversion (600 msec: 308 +/- 120 msec, P = 0.034; 500 msec: 340 +/- 208 msec, P = 0.017). No significant interaction and temporal effects were observed with regard to corrected return cycle length pattern. Similar data regarding CSNRT and corrected return cycle length pattern were obtained after autonomic blockade. Patients with abnormal CSNRT after cardioversion had higher recurrence rates (50%) than those with normal function (37%; P = NS). Patients who relapsed had a higher density of supraventricular ectopic beats per hour (159 +/- 120) compared with those who did not (35 +/- 37; P = 0.001). CONCLUSION: Depressed sinus node function is observed after conversion of chronic AF. Recovery from this abnormality and its independence from autonomic function suggest that AF remodels the sinus node. Our data do not support a causative role of sinus node function in AF recurrence, but they do indicate such a role for the density of atrial ectopic beats.

Atrial Fibrillation↗

Effects of asynchronous ventricular activation on myocardial adrenergic innervation in patients with permanent dual-chamber pacemakers; an I(123)-metaiodobenzylguanidine cardiac scintigraphic study.

AIMS: To evaluate myocardial sympathetic innervation abnormalities in patients with DDD pacemakers for complete heart block. METHODS: We studied 39 patients, chronically paced in DDD mode because of complete atrioventricular block. Twenty-three healthy individuals served as a control group. All patients underwent planar and single-photon emission computed tomography (SPECT) myocardial imaging 4 h after intravenous infusion of 185 MBq I(123)-MIBG. The heart to mediastinum ratio was calculated to quantify cardiac I(123)-MIBG accumulation, while the SPECT study was performed to investigate the regional distribution of adrenergic innervation. All patients underwent a SPECT thallium(201)myocardial study during the same week as the I(123)-MIBG study. RESULTS: The heart to mediastinum ratio was significantly smaller in paced patients than in the controls (P<0.001). 89.7% of paced patients had regional abnormalities of I(123)-MIBG uptake, mainly in the inferior (92.3%) and apical (38.5%) wall. 46.2% of paced patients had regional perfusion defects, also mainly in the inferior (46.2%) and apical (10.3%) wall. Neither the I(123)-MIBG abnormalities nor the perfusion defects were related to the duration of pacing. CONCLUSIONS: Stimulation from the apex of the right ventricle leads to regional disturbances of the adrenergic innervation of the left ventricular myocardium, as assessed by I(123)-MIBG activity.

3-Iodobenzylguanidine↗

Atrial defibrillation threshold in humans minutes after atrial fibrillation induction; "A stitch in time saves nine".

AIMS: To assess the effects of atrial fibrillation duration on the defibrillation threshold in atrial fibrillation patients seconds or minutes after initiation of the arrhythmia. METHODS AND RESULTS: Nineteen patients with recurrent symptomatic atrial fibrillation were evaluated. After programmed induction of atrial fibrillation, the defibrillation threshold was assessed after two sequential periods of arrhythmia in the same patient: an "ultrashort" period of 30 s duration and a "short" period, which lasted 10 min. After the specified period, internal cardioversion was attempted using a balloon-guided catheter that allows the delivery of biphasic shocks between one electrode array placed in the left pulmonary artery and a proximal electrode array on the lateral right atrial wall. The defibrillation threshold was assessed with energy steps of 0.5 J with a starting level of 0.5 J. Mean time from induction to successful defibrillation was 92+/-30 s after the "ultrashort" period of atrial fibrillation and 910+/-86 s after the short period. The defibrillation threshold was significantly greater after 10 min of atrial fibrillation than after 30 s of arrhythmia (2.32+/-0.61 J vs 1.31+/-0.66 J, P<0.001). Clinical data were not found to affect the defibrillation threshold. CONCLUSIONS: Prolongation of atrial fibrillation over minutes in patients with paroxysmal arrhythmia increases the energy requirements for successful defibrillation.

Aged↗

Sotalol vs metoprolol for ventricular rate control in patients with chronic atrial fibrillation who have undergone digitalization: a single-blinded crossover study.

AIMS: To compare the effects of sotalol and metoprolol on heart rate, during isotonic (ITE) and isometric (IME) exercise and daily activities, in digitalized patients with chronic atrial fibrillation. METHODS AND RESULTS: The study had a randomized, single-blinded, crossover design. Twenty-three patients with chronic atrial fibrillation received placebo for 4 weeks, followed by a 4-week period of treatment with sotalol and metoprolol in random order. At the end of each period, the patients were assessed with 24-h ECG monitoring, a cardiopulmonary exercise test and a handgrip manoeuvre. Both agents produced a lower heart rate than placebo at rest and at all levels of isotonic exercise (P < 0.001) without affecting oxygen uptake. Sotalol produced a lower heart rate than metoprolol only at submaximal exercise (116 +/- 9 bpm for sotalol vs 125 +/- 11 bpm for metoprolol, P < 0.001). During isometric exercise, sotalol produced a lower maximum heart rate than did metoprolol (113 +/- 22 vs 129 +/- 18 bpm, respectively). Both agents produced a lower mean heart rate than placebo over 24 h (P < 0.001 for all), while sotalol produced a lower mean heart rate than metoprolol during the daytime (P < 0.01). CONCLUSION: Sotalol is a safe and effective agent for control of heart rate in digitalized patients with atrial fibrillation. Sotalol is superior to metoprolol at submaximal exercise, resulting in better rate control during daily activities.

Adrenergic beta-Antagonists↗