PubMed Health⌕ Search

Biomedical subjects

P E Zuech

Publications and source records attributed to P E Zuech.

3 recordsLinked to original sources

Right ventricular function and metabolism.

Right ventricular protection may be limited with current methods of cardioplegic delivery. Sensitive measurements of right and left ventricular function and metabolism were made in 30 patients undergoing elective coronary artery bypass surgery with cold cardioplegic arrest. Myocardial adenine nucleotide concentrations decreased with cardioplegia and reperfusion in both the right and left ventricles despite adequate levels of precursors, suggesting perioperative mitochondrial dysfunction. Postoperatively, right and left ventricular pressures were measured with micromanometer catheters and volumes were measured by nuclear ventriculography. Right and left ventricular systolic elastance was calculated by the isochronic method and by the end-systolic method. Both methods provided sensitive indexes of end-systolic elastance. This study demonstrated that right ventricular function and metabolism can be evaluated by methods analogous to methods used in the left ventricle. These results suggest that right ventricular functional and metabolic recovery are delayed despite apparently adequate myocardial protection. Sensitive measurements may permit improved assessment of alternative methods of right ventricular protection.

Adenine Nucleotides↗

A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

A nonintrusive method for the visualization of pulsatile flow velocity profiles is described. The method is based on the use of a photochromic dye that is added to the fluid being studied and a nitrogen laser which excites the dye producing a marker "line" whose movement can be photographed. A microcomputer is used as a system controller, to coordinate the system timing and to manage the data transfer. The method used for analysis of the photographs to determine the velocity profiles is described. Examples are presented of instantaneous velocity profiles obtained from velocity waveforms that are similar to those of the femoral artery. In addition, application of the system for studying the relationship between Doppler ultrasound spectral recordings and flow velocity profiles is discussed.

Biomedical Engineering↗

Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedance changes and limb volume changes. Potential sources of error have also been identified. This has led to the development of clinical tests based on impedance plethysmography for the detection of peripheral arterial disease, venous insufficiency and venous outflow obstruction. Impedance plethysmography, using the method of venous occlusion, is presently the most commonly employed noninvasive method for the detection of deep venous thrombosis.

Carotid Artery Diseases↗