PubMed HealthSearch

Biomedical subjects

P Eastman

Publications and source records attributed to P Eastman.

At least 19 recordsLinked to original sources

Protein dynamics simulations from nanoseconds to microseconds.

There have been a number of advances in atomic resolution simulations of biomolecules during the past few years. These have arisen partly from improvements to computer power and partly from algorithmic improvements. There have also been advances in measuring time-dependent fluctuations in proteins using NMR spectroscopy, revealing the importance of fluctuations in the microsecond to millisecond time range. Progress has also been made in measuring how far the simulations are able to represent the accessible phase space that is available to the protein in its native state, in solution, at room temperature. Another area of development is the simulation of protein unfolding at atomic resolution.

Algorithms

Multiple time step diffusive Langevin dynamics for proteins.

We present an algorithm for simulating the long time scale dynamics of proteins and other macromolecules. Our method applies the concept of multiple time step integration to the diffusive Langevin equation, in which short time scale dynamics are replaced by friction and noise. The macromolecular force field is represented at atomic resolution. Slow motions are modeled by constrained Langevin dynamics with very large time steps, while faster degrees of freedom are kept in local thermal equilibrium. In the limit of a sufficiently large molecule, our algorithm is shown to reduce the CPU time required by two orders of magnitude. We test the algorithm on two systems, alanine dipeptide and bovine pancreatic trypsin inhibitor (BPTI), and find that it accurately calculates a variety of equilibrium and dynamical properties. In the case of BPTI, the CPU time required is reduced by nearly a factor of 60 compared to a conventional, unconstrained Langevin simulation using the same force field.

Algorithms

Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters.

PURPOSE/OBJECTIVE: The measurement of complex dose distributions (those created by irradiation through multiple beams, multiple sources, or multiple source dwell positions) requires a dosimeter that can integrate the dose during a complete treatment. Integrating dosimeter devices generally are capable of measuring only dose at a point (ion chamber, diode, TLD) or in a plane (film). With increasing use of conformal dose distributions requiring shaped, noncoplanar beams, there will be an increased requirement for a dosimeter that can record and display a 3D dose distribution. The use of a 3D dosimeter will be required to confirm the accuracy of treatment plans produced by the current generation of 3D treatment-planning computers. METHODS AND MATERIALS: The use of a Fricke-infused gel and magnetic resonance imaging (MRI) to demonstrate the localization of stereotactic beams has been demonstrated (11). The recently developed BANG polymer gel dosimetry system (MGS Research, Inc., Guilford, CT), based on radiation-induced chain polymerization of acrylic monomers dispersed in a tissue-equivalent gel, surpasses the Fricke-gel method by providing accurate, quantitative dose distribution data that do not deteriorate with time (6, 9). The improved BANG2 formulation contains 3% N,N'-methylene-bisacrylamide, 3% acrylic acid, 1% sodium hydroxide, 5% gelatin, and 88% water, where all percentages are by weight. The gel was poured into volumetric flasks, of dimensions comparable to a human head. The gels were irradiated with complex beam arrangements, similar to those used for conformal radiation therapy. Images of the gels were acquired using a Siemens 1.5T imager and a Hahn spin-echo pulse sequence (90 degrees-tau-180 degrees-tau-acquire, for different values of tau). The images were transferred via network to a Macintosh computer for which a data analysis and display program was written. The program calculates R2 maps on the basis of multiple TE images, using a monoexponential nonlinear least-squares fit based on the Levenberg-Marquardt algorithm. The program also creates a dose-to-R2 calibration function by fitting a polynomial to a set of dose and R2 data points, obtained from gels irradiated in test tubes to known doses. This function can then be applied to any other R2 map, so that a dose map can be computed and displayed. RESULTS: Through exposure to known doses of radiation, the gel has been shown to respond linearly with dose in the range of 0 to 10 Gy, and its response is independent of the beam energy or modality. Dose distributions have been imaged in orthogonal planes, and can be displayed in a convenient form for comparison with isodose plans. The response of the gel is stable; the gel can be irradiated at any time after its manufacture, and imaging can be conducted any time following a brief interval after irradiation. CONCLUSION: The polymer gel dosimeter has been shown to be a valuable device for displaying three-dimensional dose distributions. The imaged dose distribution can be compared easily with calculated dose distributions, to validate a treatment planning system. In the future, gels may be prepared in anthropomorphic phantoms, to confirm unique patient dose distributions.

Gels

Radiation therapy dosimetry using magnetic resonance imaging of polymer gels.

Further progress in the development of polymer gel dosimetry using MRI is reported, together with examples of its application to verify treatment plans for stereotactic radiosurgery and high dose rate brachytherapy. The dose distribution image produced in the tissue-equivalent gel by radiation-induced polymerization, and encoded in the spatial distribution of the NMR transverse relaxation rates (R2) of the water protons in the gel, is permanent. Maps of R2 are constructed from magnetic resonance imaging data and serve as a template for dose maps, which can be used to verify complex dose distributions from external sources or brachytherapy applicators. The integrating, three-dimensional, tissue-equivalent characteristics of polymer gels make it possible to obtain dose distributions not readily measured by conventional methods. An improved gel formulation (BANG-2) has a linear dose response that is independent of energy and dose rate for the situations studied to date. There is excellent agreement between the dose distributions predicted using treatment planning calculations and those measured using the gel method, and the clinical practical utility of MRI-based polymer gel dosimetry is thereby demonstrated.

Acrylamide