Anteroposterior drawer measurements in the knee using an instrumented test device.

A newly developed instrumented knee laxity tester was used to measure anteroposterior (AP) drawer parameters (Lachmann test) in populations of normal subjects and patients with anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) insufficiencies. The AP drawer tester features a differential electronic measuring procedure of displacements between patella and tuberosity over a continuous range between 180 and -180 N of AP forces. In the statistical evaluation, shift and compliance (or stiffness) parameters at various forces are considered. In a representative normal population, all relevant parameters were established, thus creating a normal data base for future reference. The average normal AP drawer shift between maximal anterior and posterior forces (180 N) was 6.4 +/- 1.7 mm. Right-left differences and male-female differences were found not to be statistically significant in any of the parameters. The validity of the instrumented drawer tester was confirmed relative to a group of patients with acute documented ligament insufficiencies. Measurements in two groups of patients with chronic postoperative knee instabilities revealed that although the diagnosis of instability could be confirmed, the results could hardly discriminate between ACL and PCL insufficiencies, probably due to unrecognized associated lesions at the time of operation and/or gradual postoperative developments of insufficiencies and deformities. An unexpected finding was that the mean laxities of the uninjured contralateral knees were significantly extended relative to the normal reference group, suggesting that these patients could have been classified as a high-risk group even before the time of injury.

Biomechanical Phenomena↗

Accuracy and reproducibility of instrumented knee-drawer tests.

Instrumented devices for knee-drawer tests have become popular in orthopaedics relatively recently. The objective of the present study was to document the effects of several parameters on the accuracy and reproducibility of anterior-posterior (AP) drawer measurements. An instrumented knee-drawer tester for AP laxity evaluations was constructed, based on the differential displacement method, measuring shifts of the tuberosity relative to the patella. The accuracy of the AP-shift was determined with the parallel use of a highly accurate roentgen stereo photogrammetric (RSP) measurement system on two postmortem leg specimens. The effects of relative motion between patella and femur were negligible. In addition to AP shifts, significant knee flexion and tibial rotations occurred, although the foot and the thigh were fixed as well as possible. The differential displacement method was effective in circumventing this problem. The accuracy of the AP shift was greater than 10%. The reproducibility of the AP drawer parameters (shifts and compliances) was determined in normal subjects and patients. Tests were made to evaluate the effects of different observers, time sequences, and different days. In addition, effects of muscle relaxation were studied. Overall, the shift parameters at different forces were found to be reproducible to between 5 and 15%. The slopes (compliances) of the laxity curves, at different forces, were found to be reproducible between 20 and 40%. The reproducibility was principally affected by deviations in the subject positioning procedure.

Biomechanical Phenomena↗

Horse injuries.

A series of 622 patients treated at Newmarket General Hospital for injuries resulting from contact with horses was studied. The types of injury and the manner in which they were sustained were analysed.

Accidents↗