Is transcutaneous PO2 monitoring during exercise a reliable alternative to arterial PO2 measurements?

Arterial PO2 measurement during exercise is an important part in the evaluation of pulmonary disease but requires an intra-arterial cannula. However, in clinical work it would be preferable to assess PO2 non-invasively. To evaluate such a technique, simultaneous measurements of transcutaneous PO2 (tcPO2) and arterial PO2 (PaO2), sampled from an indwelling arterial radial cannula, were made before, during and after a fatigue or symptom-limited bicycle exercise test in 16 patients referred to hospital because of dyspnoea. In total 181 paired measurements were made. Mean values (range) of PaO2 and tcPO2 were 11.2 kPa (5-16) and 9.5 (5-13.3), respectively. The correlation coefficient between PaO2 and TcPO2 was only 0.36 (P < 10(-5)). By normalizing the values of tcPO2 and PaO2 to corresponding values at supine rest before exercise, the correlation coefficient increased to 0.80 (P < 10(-6). Using PaO2 as golden standard, tcPO2 described the trend in pO2 during exercise reasonably well in all cases and this information is often sufficient for assessing the degree of pulmonary insufficiency. Thus, transcutaneous blood gas monitoring during exercise is useful for clinical evaluation of pulmonary disease, but a single arterial blood sample at rest before exercise is recommended for baseline correlation.

Aged↗

Prevention of exercise-induced asthma by drugs inhaled from metered aerosols.

The capacity of salbutamol 0.3 mg (SAL), disodium cromoglycate 3 mg (DSCG), a combination (SAL + DSCG), and ipratropium bromide 80 ug (IB), all given as metered aerosols to prevent exercise-induced (EIA), was compared with that of a placebo, a peroral lactose pill. Seven children participated, having reproducible EIA provoked by running on a treadmill at a heart rate of 170 sustained for 6 min. FEV1 and volume of trapped gas (VTG), defined as the air volume released during rebreathing oxygen with maximum breaths at the end of a multiple breath nitrogen wash out, were used as tests of spasm in large and small airways. SAL and SAL + DSCG offered complete protection in large and small airways. DSCG and IB prevented EIA in large airways (FEV1) to 95%, but only to about 50% in small airways (VTG). SAL or SAL + DSCG gave significantly better protection (FEV1 and VTG) than DSCG and IB (P less than 0.01). Differences between DSCG and IB were not statistically significant. DSCG or propellant caused significant irritation and spasm in small airways (VTG) before exercise. Most subjects seemed to obtain satisfactory protection against EIA by beta 2-agonists.

Administration, Inhalation↗