PubMed HealthSearch

Biomedical subjects

P F Hahn

Publications and source records attributed to P F Hahn.

At least 19 recordsLinked to original sources

An aqueous gastrointestinal contrast agent for use in echo-planar MR imaging.

Four volunteers were imaged with echo-planar imaging before and after ingesting a dilute barium preparation. The contrast material improved bowel visibility by increasing lumen signal intensity, without increasing noise. Long T2 gastrointestinal contrast material can be used in T2-weighted imaging when motion artifacts are suppressed by ultrashort acquisitions.

Administration, Oral

Accumulation of iron oxide particles around liver metastases during MR imaging.

The histologic nature of the bright ring ("peritumoral edema") around some liver metastases on T2-weighted magnetic resonance (MR) images is controversial. In the case reported, particles of the iron oxide contrast agent AMI-25 are retained in the peritumoral zone of a colon cancer metastasis, causing the bright ring to disappear. The location of iron particles in resected specimens could be used systematically to study peritumoral edema.

Adenocarcinoma

Palliation of malignant bile duct obstruction with metallic biliary endoprostheses: technique, results, and complications.

Expandable metallic stents were placed in 34 patients with pathologically proved malignant bile duct obstruction to determine ease of insertion, benefits of a one-stage insertion, and cost-effectiveness relative to conventional plastic stents. Thirty-eight strictures, ranging in length from 1 to 7 cm (mean, 3.2 cm), were present in the 34 patients. Strictures were located in the lower common bile duct (n = 22), middle of the common bile duct (n = 6), and hilar confluence (n = 10). In 13 patients (38%) metallic stents were placed at the time of initial biliary drainage (one-stage procedure), while the remaining patients underwent stent placement within 1-7 days of biliary drainage (two-stage procedure). Biliary obstruction was relieved in 31 of 34 patients (91%). Three patients died within 14 days of stent insertion of unrelated causes, without any change in biliary status. Mean duration of follow-up for all patients was 5.3 months (range, 0.5-14 months). Four episodes of stent occlusion occurred in three patients (12% occlusion rate); each episode was treated successfully. The average length of hospital stay for patients who underwent a one-stage procedure was 13 days (range, 3-33 days) and was 20 days (range, 9-42 days) for patients who underwent a two-stage procedure. The facility of one-step insertion, low occlusion rate, and the many strategies available for treatment of occluded stents make metallic stents an attractive alternative to conventional plastic stents in palliating patients with malignant biliary obstruction.

Adenoma, Bile Duct

Techniques for high-resolution echo-planar MR imaging of the pancreas.

Recent technical advances in echo-planar magnetic resonance (MR) imaging prompted an investigation of these new techniques in pancreatic MR imaging and evaluation of bowel lumen enhancement with an aqueous bowel contrast agent. In 42 subjects (36 healthy, six with pancreatic disease), various T1-weighted inversion-recovery and T2-weighted spin-echo fat-suppressed pulse sequences were assessed with an echo-planar technique implemented with a modified clinical MR imager. Single-excitation imaging (echo time, 26 msec) provided a higher (P less than .05) signal-to-noise ratio than did conventional spin-echo and all other echo-planar techniques. In 13 (72%) of 18 healthy subjects who did not undergo administration of the contrast agent, the entire pancreas was distinguished from adjoining bowel. In all 18 subjects who underwent contrast-enhanced imaging, a significantly greater (P less than .05) intraluminal signal intensity was apparent with all echo-planar pulse sequences and the entire pancreas was identified. In six patients with pancreatic disease, lesions could be identified by their difference in signal intensity.

Barium Sulfate

Acute complicated pancreatitis: redefining the role of interventional radiology.

Computed tomographic (CT) scans in 30 patients who had undergone percutaneous drainage for acute complicated pancreatitis were retrospectively studied to determine the role of percutaneous drainage. Fifty-nine collections were percutaneously drained in these 30 patients. Eighty-one catheters were placed in the 59 collections (average, 1.4 catheters per patient). Patients required an average of three catheter manipulations, seven abdominal CT scans, 5 weeks of catheter drainage, a mean hospital stay of 82 days (range, 42-122 days), and a mean intensive care unit stay of 31 days (range, 1-62 days). Percutaneous intervention was successful in 14 patients, partially successful in four, and unsuccessful in eight. A temporizing effect was seen in four patients. Percutaneous intervention was successful in one of 10 central (pancreas and lesser sac areas) collections and 28 of 49 peripheral collections. Surgical debridement was necessary in 16 patients because of failed or incomplete percutaneous drainage. Complications occurred in five patients, and the mortality rate was 33%. Drainage of central areas should initially be performed by a surgeon, while peripheral collections should be drained percutaneously as they develop.

Acute Disease

Measurement of tissue carcinoembryonic antigen levels from fine-needle biopsy specimens: technique and clinical usefulness.

Levels of tissue carcinoembryonic antigen (CEA) in 54 abdominal fine-needle biopsy specimens from 50 patients were measured to ascertain the use of tissue CEA levels in diagnosis of malignancy. Biopsy was performed in the following sites: liver (n = 34), retroperitoneum (n = 8), adrenal gland (n = 3), pancreas (n = 2), omentum (n = 2), pelvis (n = 2), spleen (n = 2), and stomach (n = 1). Histologic findings proved malignancy in 39 patients and benign disease in 11 patients. In these 11 patients, the mean levels of tissue CEA were lower than the normal level of serum CEA (3 ng/mL). Tissue CEA levels were higher than serum CEA levels in nine patients with colonic carcinoma and in 12 of 16 patients with noncolonic CEA-secreting malignancies. Four patients with noncolonic CEA-secreting malignancies had tissue CEA levels within the normal range (less than 3 ng/mL). Tissue CEA levels were also normal in 13 patients with various non-CEA-secreting tumors. Tissue CEA levels may prove useful in biopsy of necrotic or cystic lesions and assessment of response to ablative therapy for colon metastases.

Adult

Wallstent metallic biliary endoprosthesis: MR imaging characteristics.

Image quality and safety of magnetic resonance (MR) imaging were evaluated in vitro and in eight patients with the most commonly employed metallic biliary endoprosthesis. In vitro, the stent produced no tip deflection at 0.6 or 1.5 T. Trace magnetic susceptibility artifact, similar to artifact from a column of air, paralleled the stent. In patients, image degradation was minimal with conventional pulse sequences. Middle-field-strength spin-echo images revealed minimal artifacts indistinguishable from those produced by pneumobilia.

Biliary Tract

Sclerotherapy of malignant pleural effusion through sonographically placed small-bore catheters.

Pleural sclerosis after drainage with a small-bore catheter was performed in 21 patients with malignant pleural effusions. Intrapleural catheters 7- to 24-French in size were placed by using sonographic guidance. Tetracycline (18 patients) and bleomycin (four patients) were used as sclerosing agents (one patient had both). Clinical and radiologic follow-up was available on all patients until they died (range, 2 weeks to 25 months; mean, 3.6 months). Pleural sclerosis was successful in 15 (71%) of 21 patients. Two patients in whom pleurodesis failed had pleural sclerosis repeated, with one success and one failure. All of the failures were in patients in whom the amount of chest-tube drainage was more than 100 ml/day. Pleurodesis with tetracycline was painful in six patients; no pain was associated with use of bleomycin. Small pneumothoraces developed in four patients at the time of chest-tube placement, without consequence. A superimposed infection that developed in a patient having continuous drainage of pleural fluid was successfully treated with antibiotics. Pleural sclerotherapy can be performed through sonographically placed small-bore catheters with results comparable to those seen with large-bore, surgically placed catheters.

Adult

Malignant small bowel obstruction and ascites: not a contraindication to percutaneous gastrostomy.

Percutaneous gastrostomy (PG) with gastropexy was performed for relief of malignant small bowel obstruction in 12 patients with extensive ascites. Abdominal paracentesis was performed before PG in nine patients and after PG in one patient. Gastrostomy catheters were inserted without complication in all patients. Clinical follow up revealed that pericatheter leakage of ascitic fluid and skin excoriation occurred only in the three patients who did not have paracentesis performed before PG. No dislodgement of gastrostomy catheters occurred but mild peritonitis was noted in one patient. Our experience suggests that although in the past extensive ascites was a relative contraindication for PG, these patients can now be successfully treated with a combination of ultrasound-guided paracentesis to reduce pericatheter leakage of ascitic fluid, and gastropexy to prevent catheter dislodgement.

Abdomen

Percutaneous contact dissolution of gallstones: complexity of radiologic care.

The clinical and technical considerations for successful gallstone dissolution with methyl tert-butyl ether (MTBE) are often underestimated. Patients are selected for MTBE therapy on the basis of a functioning gallbladder without evidence of acute inflammation or calcified stones at plain radiography. A transhepatic route is favored for percutaneous insertion of the cholecystostomy catheter because of the theoretic reduced frequency of bile leakage. MTBE is delivered manually through the catheter in a closed system, with dissolution times of 4-16 hours. After MTBE dissolution, residual debris in the gallbladder is present at follow-up sonography in up to 75% of patients. The high frequency of residual debris, the potential for stone recurrence, and the labor-intensive nature of MTBE therapy make its future uncertain, especially with the advent of laparoscopic cholecystectomy.

Cholelithiasis

Benign and malignant adrenal masses: CT distinction with attenuation coefficients, size, and observer analysis.

In a retrospective study of adrenal masses evaluated with computed tomography (CT), lesion x-ray attenuation was compared with size and radiologists' interpretations in discriminating benign lesions from malignant ones. Unenhanced CT attenuation coefficient and size were analyzed electronically in 55 patients with 66 adrenal masses. There were 38 nonhyperfunctioning adenomas in 33 patients and 28 malignant masses in 22 patients. Primary extraadrenal malignancies were present in 45 of the 55 patients. Three blinded readers characterized the adrenal masses using a seven-point scale of certainty. Results were subjected to receiver operating characteristic (ROC) analysis. The mean CT attenuation coefficient for benign adrenal masses was -2.2 HU +/- 16.0 and was significantly different from the mean for malignant lesions (28.9 HU +/- 10.6). The area under the ROC curve for CT attenuation coefficients (0.91 +/- 0.04) was significantly larger than that for lesion size (0.84 +/- 0.05) or best observer interpretation (0.84 +/- 0.05). A threshold CT attenuation value of 0 HU had a sensitivity-to-specificity ratio of 47%:100% for characterizing benign adrenal masses, whereas a threshold attenuation of 10 HU had a ratio of 79%:96%.

Adrenal Gland Neoplasms

Importance of daily rounds by the radiologist after interventional procedures of the abdomen and chest.

A prospective study was performed to evaluate the clinical utility of daily rounds by the radiologist for patients with indwelling catheters in the chest and abdomen, placed during interventional radiologic procedures. The 7-week evaluation included documentation of the number of patients seen, time spent with each per day, number of problems identified, management of these problems, and consultations for new cases generated by interaction with other staff. During the 268 visits to 37 patients, 59 catheter-related problems were identified; 17 (29%) required further intervention in the radiology department, and 42 (71%) were managed at the patient's bedside. Of the patients who were followed up, 22 (59%) had some catheter-related problem identified during their hospital stay. Daily rounds by the radiologist are an essential component of patient care after catheter-related interventional procedures and should be made by those who perform and understand the procedures.

Catheterization

MR imaging of liver metastases at 1.5 T: similar contrast discrimination with T1- and T2-weighted pulse sequences.

The authors evaluated soft-tissue contrast on spin-echo (SE) proton density-weighted, SE T2-weighted, SE short-echo-time (TE) T1-weighted, and gradient-echo (GRE) images of 34 patients with known hepatic tumors who underwent high-field-strength (1.5-T) magnetic resonance imaging. For solid liver tumors, the difference in the mean lesion-liver contrast-to-noise ratios (C/Ns) with T1- (GRE and SE) and T2-weighted pulse sequences was not statistically significant (P greater than .05). For nonsolid liver tumors, the T2-weighted images provided significantly greater (P less than .05) mean lesion-liver C/N than T1-weighted GRE images. Mean liver signal-to-noise ratio was significantly greater on T1-weighted GRE (P less than .0001) and T1-weighted SE (P less than .05) images than on T2- and proton density-weighted images. Qualitative analysis of T1-weighted (SE and GRE) images and proton density- plus T2-weighted images showed that lesion conspicuity was similar in 25 of 32 patients (78%). The results suggest that liver tumor imaging at high field strength can be performed with short-TE T1-weighted (SE or GRE) or conventional T2-weighted pulse sequences.

Humans

Focal nodular hyperplasia of the liver: MR findings in 35 proved cases.

MR images of 28 patients with 35 lesions of hepatic focal nodular hyperplasia were reviewed to determine the frequency of findings considered typical of this condition (isointensity on T1- and T2-weighted pulse sequences, a central hyperintense scar on T2-weighted images, and homogeneous signal intensity). Fifteen lesions were imaged at 0.6 T with T1- and T2-weighted spin-echo (SE) pulse sequences; 20 lesions were imaged at 1.5 T with T1-weighted SE and gradient-echo pulse sequences and T2-weighted SE pulse sequences. Diagnosis of focal nodular hyperplasia was made pathologically in 25 patients, with nuclear scintigraphy in four, and with follow-up imaging in six. Only seven lesions (20%) were isointense relative to normal liver on both T1- and T2-weighted images. On T1-weighted SE images, 21 lesions (60%) were isointense relative to normal liver, 12 (34%) were hypointense, and two (6%) were hyperintense. On T2-weighted SE images, 12 lesions (34%) were isointense and 23 (66%) were hyperintense relative to normal liver. A central scar was present in 17 lesions (49%) and was hypointense relative to the lesion on T1-weighted images and hyperintense on T2-weighted images. Twenty lesions (57%) were of homogeneous signal intensity throughout the lesion, except for the presence of a central scar. All three MR imaging characteristics were present in three cases (9%). We conclude that hepatic focal nodular hyperplasia has a wide range of signal intensity on MR imaging.

Adult

Treatment of critically ill patients with sepsis of unknown cause: value of percutaneous cholecystostomy.

Because of the difficulty in diagnosing acute cholecystitis in critically ill patients with severe intercurrent illness by clinical and imaging methods or percutaneous aspiration of the gallbladder, a trial of percutaneous cholecystostomy was performed in 24 patients in the intensive-care unit with persistent, unexplained sepsis after a complete clinical, laboratory, and radiologic search showed no alternative source of infection. Persistent high fevers, despite antibiotic therapy, were present in all patients, with elevated WBC count in 18 patients, vague abdominal tenderness in 11, and septic shock requiring vasopressors in 15. Sonographically, all patients had distended, spherical gallbladders, six had gallstones, eight had wall thickening, three had pericholecystic fluid, and four had Murphy's sign. All patients were seen by a senior abdominal surgeon, who agreed to a trial of percutaneous cholecystostomy. Fourteen patients (58%) responded to percutaneous cholecystostomy, as evidenced by a decrease in WBC count, defervescence, and the ability to be weaned off vasopressors. Bile cultures were positive in four patients. Ten patients (42%) did not respond to percutaneous cholecystostomy; five eventually died of unrelated causes. A respiratory source of infection was eventually found in three of these 10 patients, with no proved source of infection in the remainder. No complications related to catheter insertion occurred in this group of patients. Bile leaks occurred in two patients when the percutaneous cholecystostomy catheter was removed, but without serious consequence. Our experience suggests that a lower threshold for performing percutaneous cholecystostomy in this difficult clinical subset of patients is worthwhile.

Acute Disease

Differentiation between hemangiomas and metastases of the liver with ultrafast MR imaging: preliminary results with T2 calculations.

We studied the efficacy of T2 measurements at high field strength in distinguishing between liver hemangiomas and hepatic metastases when an ultrafast (single-excitation) MR imaging technique is used. Fourteen patients with known liver tumors were imaged in a 2.0-T prototype ultrafast MR scanner with a spin-echo (infinite TR and TE of 30-340 msec) pulse sequence. Each image was obtained with a total data acquisition time of 20 msec. T2 calculations for hepatic metastases (n = 6) showed a mean of 79.3 +/- 13.5 msec, whereas hemangiomas (n = 8) showed a T2 of 139.8 +/- 18.8 msec (p less than .0001). T2 values of lesions had a smaller relative standard deviation than previously reported, and the range of T2 values of hemangiomas (119-181 msec) and metastases (68-103 msec) did not overlap. Our preliminary results suggest that T2 calculations with ultrafast MR imaging may be useful for differentiating hemangiomas from metastases. We hypothesize that T2 values obtained from ultrafast MR images are more reliable than those obtained from conventional MR images, primarily because of the elimination of T1 information and effects of motion on image signal intensity.

Carcinoid Tumor