PubMed Health⌕ Search

Biomedical subjects

P F Wretenberg

Publications and source records attributed to P F Wretenberg.

6 recordsLinked to original sources

Methodological concerns using intra-cortical pins to measure tibiofemoral kinematics.

The complexity of human tibiofemoral joint motion is now better understood with the advancement of new methodologies to measure tibiofemoral kinematics in vivo. Marker clusters anchored to stainless steel bone pins inserted directly into the femur and tibia provide the most sensitive and accurate means for directly measuring skeletal tibiofemoral joint motion. Despite its invasiveness, this technique has been successful, although complications have been reported with the femoral pin and its insertion site. The purpose of this technical report is twofold: to review the difficulties with the femoral pin and its insertion site from a historical perspective, and to identify the load force required from biological tissue to permanently deform the pin. In addition, proposals in the advancement of this method are discussed in the context of reducing impingement with the femoral pin and the Iliotibial band. Because stainless steel exhibits plastic behaviour with no sharp yield point, Apex self-drilling/self-tapping bone pins underwent incremental loading on an Instron materials testing machine. Loads were transmitted perpendicular to the pin with the threads partially exposed and fully secured in vice. Since the accuracy of our combined stereophotogrammetry and Optoelectric motion analysis was less than 0.4 mm, it was decided that plastic deformation occurred after deflections of 0.4 mm. With exposed threads, deflections larger than 0.4 mm were observed at 150 N and 100 N when loads were applied at 15 mm and 20 mm from the vice (representative of where the tissue came in contact with the pin). Loads greater than 200 N produced deflections less than 0.2 mm when threads were fully inserted. The 90 Hz resonant frequency for the marker cluster-bone pin complex is beyond the spectrum of human movement and can be lowpass filtered. To reduce impingement and pin bending, one solution may be to implant pins with a shorter threaded section. By completely penetrating the bone, only the smooth surface of the pin is exposed which is more resistant to bending. Otherwise pins with larger diameters and longer longitudinal incisions about the femoral insertion site are an alternative. Lengthening the longitudinal incisions about the insertion site, and correctly aligning and inserting the femoral pin between the Iliotibial band and quadriceps tendon may diminish impingement. Performing dynamic open chain flexion and extension movements while on the operating table may aid in aligning the pin at the incision site. This may stretch the IT band and quadriceps tendon and may guide the femoral pin into a more optimal position prior to it being inserted into the cortex of the bone.

Biomechanical Phenomena↗

Assessment of functional knee bracing: an in vivo three-dimensional kinematic analysis of the anterior cruciate deficient knee.

OBJECTIVE: To describe three-dimensional tibial and femoral movements in vivo and examine the effect of a brace on knee kinematics during moderate to intense activity. DESIGN: Skeletal kinematics of anterior cruciate ligament deficient knees was measured with and without braces during moderate to intense activity. BACKGROUND: Invasive markers implanted into the tibia and femur are the most accurate means to directly measure skeletal motion and may provide a more sensitive measure of the differences between brace conditions. METHODS: Steinmann traction pins were implanted into the femur and tibia of four subjects having a partial or complete anterior cruciate ligament rupture. Non-braced and braced conditions were randomly assigned and subjects jumped for maximal horizontal distance to sufficiently stress the anterior cruciate ligament. RESULTS: Intra-subject peak vertical force and posterior shear force were generally consistent between conditions. Intra-subject kinematics was repeatable but linear displacements between brace conditions were small. Differences in angular and linear skeletal motion were observed across subjects. Bracing the anterior cruciate ligament deficient knee resulted in only minor kinematic changes in tibiofemoral joint motion. CONCLUSION: In this study, no consistent reductions in anterior tibial translations were observed as a function of the knee brace tested. Relevance. Investigations have reported that knee braces fail when high loads are encountered or when load is applied in an unpredictable manner. Questions remain regarding tibiofemoral joint motion, in particular linear displacements. The pin technique is a means for direct skeletal measurement and may provide a more sensitive measure of the differences between brace conditions.

Adult↗

Complex cemented revision using polished stem and morselized allograft. Minimum 5-years' follow-up.

The aim of this study was to evaluate the results of complex hip revision using a cemented, collarless and polished femoral stem design (CPT, Zimmer, Warsaw, In.) within a tightly impacted morselized allograft. We have now been using the impaction grafting technique in combination with the CPT stem (Zimmer) for 10 years in complex cases of severe bone loss. In this study we have elected to report only those patients who have been revised at least once before revision using the impaction grafting technique. All the patients in the study group have a minimum follow-up of 5 years after the impaction grafting revision. In total, 43 consecutive hips in 40 patients, 22 men and 18 women, with a follow-up time of between 5 and 7 years are included in the study. The complications related to the revised hip consist of three early dislocations managed by closed reduction. Two patients suffered from periprosthetic fracture, both managed with plate osteosynthesis. Two cementless sockets were revised due to aseptic socket loosening. The Endoklinik rating of preoperative bone loss for the revised hips was 2 in 13 hips, 3 in 23 hips, and 4 in 7 hips. During the first year 29 stems subsided 2-4 mm within the cement mantle. In 8 cases, a subsidence of 5-9 mm was measured. The subsidence was nonprogressive, and no subsidence occurred after the 1st year. The Charnley, D'Aubigne, Postel scoring (maximum 6 points) for pain improved from 2.2 points preoperatively to 4.4 postoperatively, function from 2.3 to 4.3, and movement from 2.3 to 4.1. In conclusion, the concept of impaction grafting in THR revision in our study has so far proven to be successful with good clinical results at 5 years despite the relatively high early subsidence of the femoral component.

Aged↗

Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint.

The purpose of this review article is twofold: to report on the use of intracortical pins to measure three-dimensional tibiofemoral and patellofemoral joint kinematics and highlight methodological concerns associated with this procedure. Tibiofemoral and patellofemoral kinematics has been extensively investigated using reflective markers attached to the surrounding soft tissue of the calf and thigh. However, surface markers may not adequately represent true anatomical locations and skin movement artefacts present the most critical source of measurement error. Consequently, knowledge about skeletal tibiofemoral kinematics is limited, in particular abduction-adduction and internal-external rotations. Considerable questions remain regarding what constitutes normal motion of the knee. A way to avoid the problem of surface markers is use invasive markers to directly measure skeletal motion. To date, many co-ordinate systems have been used to describe three-dimensional skeletal kinematics of the lower limb in vivo. They include helical axes, finite helical axes, instantaneous helical axes, and the joint co-ordinate system based on local anatomic landmarks. Although each method accurately describes the relative motion in 6 d. of f., the differences in how the motion is partitioned may account for the differences across investigations. Additionally, the problem of defining the anatomical co-ordinate system makes comparisons across subjects and studies difficult since subtle differences may be caused by small deviations in the anatomical reference alignment. Cross talk is also a primarily a concern. For joints that articulate principally about one axis, the primary flexion/extension that is registered will be cross-talked into ab/adduction and internal/external rotations.

Biomechanical Phenomena↗

The Kessel total shoulder arthroplasty. A 13- to 16-year retrospective followup.

Between 1982 and 1985, 23 Kessel total shoulder arthroplasties were performed on 22 patients with rheumatoid arthritis. A clinical and radiographic review of the 5-year experience was evaluated in 1988 and published in 1992. Ten years later a followup study was done. Of the 22 patients, 11 have died and two were seriously ill and could not participate. Of the remaining nine patients, one had revision surgery after 2 years, leaving eight patients with a mean age of 61 years for this followup study. Shoulder function was evaluated subjectively using the Simple Shoulder Test, and pain was evaluated using a visual analog scale. New radiographs were taken. In general, the patients had a low functional level, but they were able to sleep on the surgically treated side and to manage daily hygiene. Five patients were pain free, and the worst recorded pain during the day was 35 mm on the visual analog scale. Two patients had their scapular component cemented at primary surgery. The radiographs showed no radiolucent zones around these components. The six other scapular components had radiolucent zones of 1 to 3 mm. No radiolucent zones were detected around the humeral components.

Activities of Daily Living↗