Preoperative assessment of the patient with cardiovascular disease.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to P Foëx.
Explore the source record for details and available documents.
The effects of increasing inspired halothane concentration (0.5, 1.0, 1.5, 2.0 per cent) upon left ventricular myocardium supplied by a critically narrowed coronary artery and a normal coronary artery were studied in 11 open-chested dogs. Regional ventricular function was measured by continuous recording of ventricular segment length using pairs of implanted miniature ultrasonic length detectors in the left anterior descending coronary artery (LAD) and left circumflex coronary artery (LC) territories before and during critical stenosis of the LAD by a micrometer-controlled snare. Critical narrowing was documented by ischemic regional ventricular function (i.e., post-systolic shortening; systolic lengthening) limited to the LAD territory when FIO2 = 0 for 90 seconds. Hemodynamic variables (aortic, left atrial and left ventricular pressure, and heart rate) were measured, ECG lead II was recorded, and the first derivative of left ventricular pressure (LV dP/dt) and coronary perfusion pressure derived for each halothane concentration before and during LAD narrowing. Increasing halothane was associated with equivalent progressive depression of global ventricular function before and during LAD constriction. Prior to LAD constriction, no ischemic changes in regional function occurred. Regional ventricular function was normal during 0.5 percent halothane in the presence of LAD constriction. With increasing halothane during LAD constriction, ischemic regional ventricular function was observed in the LAD territory in eight of eleven hearts, whereas regional ventricular function remained normal in the LC territory. The epicardial ECG was recorded in three dogs and was insensitive as an indicator of ischemia, becoming abnormal only after severe ischemic changes were established. In these studies, in which heart rate remained constant, arterial blood pressure and LV dP/dt decreased, and left ventricular end-diastolic pressure increased, decrease in blood flow and oxygen delivery due to a lower perfusion pressure distal to the coronary artery narrowing appears to be primarily responsible for the observations. The authors hypothesize that clinically unapparent episodes of regional myocardial ischemia distal to narrowed coronary arteries may be an important cause of perioperative myocardial infarction.
Explore the source record for details and available documents.
Two types of titration curve (log PCO2 vs. pH and whole blood [HCO3-] vs. pH) were obtained in anaesthetized dogs by altering FICO2. Both plots reveal a significant progressive decrease in slope from arterial(a) to mixed venous (v) to coronary sinus (cs) blood. Lines drawn between corresponding points on the arterial and mixed venous or coronary sinus curves have slopes determined by the Respiratory Exchange Ratio (R) and are called R lines. Differences in slope between arterial and venous (v or cs) curves may be due to changes in blood flow or of delivery of CO2 to the blood. The former is indicated by constant R values at different CO2 tensions whilst the latter is a reflection of changing R values due to fluctuations in CO2 stores. The myocardium is not an important store for CO2 but CO2 has a profound effect on coronary blood flow and it is this that causes the difference in a-cs slopes. The reverse is true for skeletal muscle where the charging and discharging of CO2 stores brings about the difference in a-v slopes.
Over the last twenty-five years, the treatment of circulatory failure has been profoundly modified not only by the introduction of new therapeutic agents but also by considerable advances in the understanding of the circulation in the severely ill patient. The considerable hazards of increasing blood pressure by the administration of vasoconstrictive agents have been recognized and it has become obvious that the first step in the treatment of circulatory failure is to ensure adequate filling of the vascular compartment. If correction of the pre-load does not improve the circulation, positive inotropic agents may find their indication and may improve cardiac output. The increased myocardial oxygen demand, the development of tachycardia and dysrhythmias may limit their usefulness. In the presence of high filling pressures, inotropic agents may improve the circulation but often better results are obtained from the administration of vasodilators. Artificial circulatory support by aortic balloon counterpulsation may have to be used as a last resource. The difficulties encountered in the treatment of acute circulatory failure relate to the delicate balance between myocardial oxygen demand and supply. Inotropic agents enhance performance, increase heart rate, systolic pressure and oxygen demand. Conversely, vasodilators by decreasing diastolic pressure may also decrease oxygen supply. Thus, it is not surprising that the treatment of circulatory failure remains difficult.
A technique was developed for the in vivo determination of PO2 and PN2O with a catheter electrode using double-pulse polarography. The method was evaluated in dog studies comparing readings from the electrode with those from a mass spectrometer employing an in vivo probe. The oxygen readings obtained from the catheter electrode were also compared with values obtained by conventional blood-gas analysis. Good agreement was observed between the electrode and the mass spectrometer for both PO2 and PN2O. Similar agreement was found between the electrode readings and blood-gas analysis for PO2. In the presence of halothane, the electrode over-read for both PO2 and PN2O; a remedy is suggested. The in vivo electrode provides an effective, less expensive, alternative to the mass spectrometer for the on-line measurement of PO2 and PN2O in vivo.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The haemodynamic responses to isovolumic anaemia (dextran-for-blood exchange) were studied in seven dogs pretreated with propranolol 20 mg/kg body weight for 3 weeks. Adrenergic beta-receptor blockade did not prevent significant increases in heart rate (up to 19%). Cardiac output increased by about 20% while systemic vascular resistance decreased by the same proportion. Oxygen extraction increased from 24% to 35% and this was reflected by a decrease in mixed venous PO2 by 1.2 kPa. The modest hyperdynamic response of the circulation to haemodilution in the presence of high-grade adrenergic beta-receptor blockade is in sharp contrast with the large hyperdynamic response that has been reported in its absence and indicates that normal compensatory mechanisms are considerably impaired.
Continuous analysis of oxygen and carbon dioxide tension in the blood phase, over periods of 4-5 h, was carried out in the pulmonary artery (93 determinations in six anesthetized dogs) and in the aorta (29 determinations in four anaesthetized dogs). Silastic-covered stainless steel catheters attached to a mass spectrometer were used. The mass spectrometer signals were linearly related to the blood-gas tensions measured by conventional analysis. The mass spectrometer signals were calibrated in vivo by exposing the animals to high and low oxygen and carbon dioxide tension. With such in vivo calibration the slopes of the straight line regressions for mass spectrometer PO2 or PCO2 on PO2 or PCO2 by conventional analysis were comprised between 0.944 and 1.031 while the standard error of the slopes were between 0.019 and 0.031. Deliberate reductions of cardiac output had little effect on the mass spectrometer readings.
The effects of metoprolol 1 mg kg-1 i.v. on the systemic and coronary circulations and on myocardial performance were studied in nine open-chested dogs ventilated with halothane 0.8% in oxygen at normocarbia. In terms of the chronotropic effect, this dose of metoprolol produced a substantial shift to the right of the dose-response curve to isoprenaline; substantial reductions of arterial pressure (10%), cardiac output (21%), aortic blood acceleration (13%), left ventricular dP/dt max (13%) and left ventricular power (25%) were observed. Both preload, represented by left ventricular end diastolic pressure, and afterload, represented by systemic vascular resistance, increased. Left circumflex coronary blood flow and myocardial oxygen consumption decreased by approximately the same amount as peak ventricular power.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Properties of oxygen-haemoglobin binding have been investigated in the aquatic turtle Psuedemys scripta and the terrestrial tortoise Testudo graeca. Haematocrit (30-35%) and haemoglobin concentration (12-14 g/100 ml blood) were similar in both species. P50 at physiological levels of PCO2 (20-25 mm Hg) was 21 mm Hg in Pseudemys, compared with 23 mm Hg in Testudo. The Bohr shift of the blood of both the turtle and the tortoise was almost identical at -0.28. The heat of oxygenation, deltaH, reflecting the temperature sensitivity of O2-Hb affinity, was -10.55 in Pseudemys and -8.12 kcal/mol in Testudo. These data on whole blood do not support previous generalizations in the literature suggesting marked differences in oxygen-haemoglobin binding between aquatic and terrestrial chelonian reptiles.
In six dogs chronically implanted with flow and pressure transducers, equipotent inspired concentrations of halothane and isoflurane were determined as the minimum inspried concentration of each agent which would abolish an individual dog's response to paw clamping. In equipotent concentration, isoflurane (1.2%, SD 0.2%) caused less myocardial depression than halothane (1.0%, SD 0.1%). Dose-response studies were possible up to a mean inspired isoflurane concentration of 3.0%, both before and after propranolol 0.3 mg kg-1, i.v. After propranolol, sensitive indices of myocardial contractility were depressed at all concentrations of isoflurane, indicating a moderate degree of beta-receptor activation by isoflurane. The haemodynamic response to hypovolaemia during isoflurane anaesthesia was not modified by propranolol.
The effect of pretreatment for 3 weeks with propranolol 20 mg/kg/day on cardiovascular function during increasing depths of halothane anaesthesia (range 1.0-2.5% inspired halothane with IPPV and normocapnia) were studied in a group of seven closed-chest dogs which had been implanted previously with cardiovascular flow- and pressure-measuring instruments. The results were compared with those observed in a similar group of five untreated dogs. Propranolol pretreatment resulted in a small degree of additional cardiac depression at any inspired halothane concentration. The cardiac depressant effects of propranolol and halothane were found to be simply additive and therefore predictable. The presence of propranolol did not result in morbidity or mortality at any depth of halothane anaesthesia.
Beta-adrenergic blockade may impair the normal cardiovascular response to hypoxia occurring during general anaesthesia. The haemodynamic effects of acute hypoxia, induced by a 90-s period of ventilation with nitrogen, were studied during increasing depths of halothane anaesthesia up to a maximum of 2.5% inspired halothane in dogs chronically implanted with intracardiac catheters, a left-ventricular pressure transducer and an aortic blood flow transducer. An untreated group of dogs and a group which had been treated for 3 weeks with propranolol 20 mg/kg/day were compared. The beta-blocked group had lesser cardiac output values, left-ventricular contractility indices, external left-ventricular work and peak left-ventricular power at all depths of anaesthesia except 2.5% halothane, but both groups responded to hypoxia similarly at each depth of anaesthesia. Cardiac performance was enhanced in both groups during acute hypoxia. No adverse haemodynamic effect of the combination of propranolol, halothane and hypoxia was demonstrated.
We have examined the haemodynamic effects of 0.8% trichloroethylene and 1% halothane anaesthesia in a control group of five dogs, chronically implanted with cardiovascular flow- and pressure-measuring apparatus and compared them with a similar group of six dogs pretreated for 3 weeks with oral propranolol (20 mg/kg/day). The effects of graded haemorrhage of 25% of the estimated blood volume and re-transfusion were studied. Cardiovascular function was satisfactory at all stages of the study except during trichloroethylene anaesthesia in the beta-blocked dogs when the response to blood loss was impaired severely. Therefore the use of trichloroethylene in the presence of propranolol may not be advisable in clinical practice.