PubMed Health⌕ Search

Biomedical subjects

P Fontanille

Publications and source records attributed to P Fontanille.

10 recordsLinked to original sources

Optimization of isonovalal production from alpha-pinene oxide using permeabilized cells of Pseudomonas rhodesiae CIP 107491.

Optimization studies on the synthesis of isonovalal from alpha-pinene oxide by Pseudomonas rhodesiae CIP 107491 operated in a biphasic medium are presented. Three key parameters are identified. The first is the need for a permeabilization of cells by freezing them and then treating the thawed material with an organic solvent such as chloroform, toluene or diethyl ether. This operation allows both enzyme release into the aqueous phase outside the cells and an improvement in the transport properties of both substrate and product across the cell membrane, strongly increasing reaction rates. The second is that the enzyme alpha-pinene oxide lyase, which exhibits an irreversible inactivation by isonovalal (or a by-product), presents a constant turn-over, i.e., the total product synthesis is proportional to the biomass loading and is close to 108 mmol (16.4 g) isonovalal l(-1) g(-1) biomass. The third phenomenon is that the biphasic system used is not phase-transfer-limited, a feature attributed to the spontaneous formation of an oil-in-water emulsion. It is thus possible to carry out a very efficient process, allowing the recovery of 2.63 mol isonovalal l(-1) (400 g l(-1)) from 25 g biomass l(-1) in 2.5 h, corresponding to an average reaction rate as high as 0.70 mmol min(-1) g(-1) cells (160 g l(-1) h(-1)).

Aldehydes↗

Direct analysis of fluoxetine and norfluoxetine in plasma by gas chromatography with nitrogen-phosphorus detection.

A quantitative method for the simultaneous GC resolution and detection of fluoxetine and his metabolite norfluoxetine in human plasma was developed. The procedure required 1.0 ml of plasma, extraction with a mixed organic solvent and injection into a capillary gas chromatograph with an OV-1 fused-silica column coupled to a nitrogen-phosphorus detector. The calibration curves were linear over the range 5-3000 ng/ml. The detection limits were 0.3 and 2 ng/ml for fluoxetine and norfluoxetine, respectively. The assay is suitable for routine analysis.

Chromatography, Gas↗

[Compared diagnostic performances of CKMB measurements by immuno-inhibition and three immunoenzyme methods for the early diagnosis of myocardial infarction].

In 98 patients consecutively admitted in a medical intensive care unit, an aliquot taken from the blood sample withdrawn for the cardiac enzyme admission request has been frozen. After thawing of these 98 aliquots total CK and the creatine kinase MB isoenzyme were measured on the same day. For this last determination, four methods were used and compared: an immunoinhibition method (Merck) and three immunoenzymatic assays (Abbott on IMX; Baxter on Stratus II; Hybritech on single use Icon cylinder). In 19 out of the 98 patients studied the diagnosis of myocardial infarction was made retrospectively by a cardiologist. This diagnosis was established according to the criteria defined by the WHO. The clinical performances (sensitivity, specificity, positive predictive value, negative predictive value) have been calculated for each test according to the following criteria: on the one hand, a cut-off of 8% (reference range of our laboratory) for the immunoinhibition technique; on the other hand, a cut-off defined by the manufacturer together with a cut-off obtained from the ROC curves for the three immunoenzymatic assays. Our results clearly demonstrate that the clinical performances of the three immunoenzymatic CKMB assays are very comparable and appear to be much better than the immunoinhibition method which should be abandoned.

Adult↗