PubMed Health⌕ Search

Biomedical subjects

P G Begemann

Publications and source records attributed to P G Begemann.

6 recordsLinked to original sources

[16-Row multidetector CT of the pelvis after iliosacrally inserted osteosynthetic screws: experimental study of dose adjustment on preserved human cadaver specimens].

PURPOSE: The study was performed to assess the necessity of dose adjustment (kV or mAs (eff.)) in 16-slice CT (MDCT) in postoperative controls of iliosacrally inserted osteosynthetic screws (OS) on preserved human cadaver specimens. The minimal tube settings for diagnostic imaging of the pelvic bone were analyzed and the effective doses and important organ doses were calculated. MATERIALS AND METHODS: 16 preserved human cadaver specimens with transiliac osteosynthetic screws were scanned on a 16-slice CT (collimation 16 x 0.75 mm, pitch 0.7) with 10 different tube settings (35, 50, 75, 100, 150 mAs (eff.) and 120 and 140 kV). 32 datasets (blinded for name and scan parameters) with and without OS were independently evaluated by four observers. The 10 series were sorted by subjective image quality (image noise, contours, artifacts), and the series with the lowest but still diagnostic quality was selected. The statistical analysis included multi-rater-kappa-test and Wilcoxon test for paired samples. RESULTS: The multi-reader agreements for sorting the series were fair (kappa = 0.38). The agreements in comparing the lowest diagnostic image qualities were slight to fair (kappa = 0.08-0.23). The paired sample test comparing the lowest diagnostic image quality with and without OS showed no statistical significance (p = 0.29). 87.5 % of the readouts (n = 64 [16 examinations, 4 readers]) with OS and 78.1 % of those without OS could be adequately diagnosed using the three series with the lowest effective doses (0.9-1.4 mSv for men, 1.4-2.0 mSv for women; 120 kV-35 mAs (eff.), 120-50, 140-35). CONCLUSION: MSCT scans of the pelvic bone can be performed with very low effective doses. It is not necessary to adjust tube settings when imaging bones with osteosynthetic screws. If the concept for the control of the pelvic osteosynthetic screw position includes more than 2 conventional films (for example anterioposterior view with additional inlet and outlet views), a low dose CT is preferable to conventional radiography.

Animals↗

Experimental 16-row CT evaluation of in-stent restenosis using new stationary and moving cardiac stent phantoms: experimental examination.

PURPOSE: The aim of this study was to evaluate in-stent restenosiss using a newly developed stationary and moving cardiac stent phantom with three built-in artificial stenoses and a 16-row MDCT. MATERIALS AND METHODS: A newly developed coronary stent phantom with three artificial stenoses--low (approx. 30 %), medium (approx. 50 %) and high (approx. 70 %)--was attached to a moving heart phantom and used to evaluate the ability of 16-row MDCT to visualize in-stent restenosis. High resolution scans (16 x 0.75 mm, 250 mm FOV) were made to identify the baseline for image quality. The non-moving phantom was scanned (16 x 0.75 mm, routine cardiac scan protocol) first without and then with implementation of an ECG signal at various simulated heart rates (HR 40 to 120 bpm) and pitches (0.15 to 0.3). The moving cardiac phantom was scanned at the same simulated heart rates but at a pitch of 0.15. Images were reconstructed at every 10 % of the RR interval using a multi-cycle real cone-beam reconstruction algorithm. Multi-planar reformations (MPR) were made for the image evaluation. The image quality was assessed using a three-point scale, and stent patency and stenoses detection were evaluated using a four-point scale. To evaluate the image quality and to grade the stent stenoses, the median values were calculated while considering the reconstruction interval. RESULTS: The image quality for the static phantom was adequate in 97 % of the measurements. In this phantom, every stenosis was detected independent of the pitch and heart rate used. The dynamic stent phantom yielded the best results at 0 %, 40 %, and 50 % of the RR interval at a pitch of 0.15. The low stenosis was visible at a simulated heart rate of up to 80 bpm. Patency can be detected at heart rates greater than 80 bpm. CONCLUSION: The newly developed moving stent phantom allowed a nearly in-vivo condition for detecting re-stenoses within a stent. In this phantom study the use of a 16-row MDCT allowed the detection of re-stenosis within a coronary stent at a heart rate of up to 80 bpm. This phantom can then be used for future studies, e. g. with a 64-row MDCT.

Artifacts↗

Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Currently there are few data available regarding the application and efficacy of computer-assisted procedures in the sacral spine. In order to optimize and standardize this procedure, a controlled experimental investigation has been performed. The aim of the study is to systematically assess the efficacy of a novel three-dimensional image intensifier used for navigated transiliac screw insertion into the first sacral vertebra. Screws were inserted iliosacrally into the first sacral vertebra of preserved human cadaver specimens. The instrument navigated procedure was performed with the "Siremobil Iso-C(3D) " (Siemens Medical Solutions) and the "Navigation System" by Stryker. The accuracy and quality of the imaging procedure as well as the fluoroscopic exposure times were measured. These results were compared to three control groups (CT-based navigation, C-arm navigation, and fluoroscopic guidance). In each group a total amount of 20 screws was implanted. Screw position was postoperatively assessed by Iso-C(3D) or CT-scan. The navigated procedure using the Iso-C(3D) provided good feasibility characteristics without requiring a specific matching process. It revealed the shortest procedure time of all navigated procedures and significantly decreased fluoroscopic time compared to C-arm navigation and fluoroscopic guidance. Furthermore, Iso-C(3D) navigation showed no screw malposition and was in this regard superior to C-arm navigated and fluoroscopic guided procedures. The quality of imaging was sufficient for accurate placement, but did not share the high-resolution level of CT-based navigation. These findings indicate that application of the Iso-C(3D) for navigated transiliac screw insertion into S1 can be recommended as a feasible and safe technique, enabling the surgeon to reduce procedure and fluoroscopic time. Further progress in improving the quality of the Iso-C(3D) image should be attempted.

Bone Screws↗

[The ECG-gated 4-row multidetector CT of the heart in preoperative imaging minimal invasive coronary artery bypass grafting].

PURPOSE: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. MATERIAL AND METHODS: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4 x 2.5 mm) and contrast-enhanced examination (140-170 ml, 300 mg Iodine/ml, collimation 4 x 1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), course of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. RESULTS: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and at surgery. Bridging of epicardial fat was shown by MDCT and at surgery in 9/25 patients and was excluded in 15 patients. In 1 patient, the LAD seemed to run superficially in MDCT, but was covered with fat as seen during surgery. The course of the LIMA was inconspicuous in all cases, no pleural fibrosis was found. CONCLUSIONS: The 4-row MDCT has proven to be adequate in addition to coronary angiography for preoperative evaluation in patients scheduled for MIDCAB and provides the surgeon with relevant information for the selection of the operative approach.

Aged↗

[Evaluation of experimental cartilage lesions with ultrahigh-resolution multi-slice-CT in comparison to histology].

PURPOSE: Histologic validation of ultrahigh-resolution multi-slice (MS)-CT for the evaluation of focal, experimental cartilage lesions with special regard to the subchondral bone. Testing of micro-CT ( micro CT) as alternative reference standard. METHODS: 32 experimental cartilage lesions in bovine patellae were imaged surrounded by air (MS-CT-air) and immersed in a contrast material solution (MS-CT-CM) with MS-CT (collimation 2 x 0,5 mm). After the micro CT (8 micro m-voxelsite) examination in three specimen and histologic work-up of 29 specimen two radiologist graded the defects on MS-CT images in consensus (subchondral bone involvement yes or no) and results were compared to the results of histomorphometry and micro CT. RESULTS: The MS-CT-air and -CM had an accuracy of 94 % (30/32) and 88 % (28/32), respectively. MS-CT-air led to one false-positive (remaining cartilage: = 0,1 mm) and false-negative result, each. MS-CT-CM showed false-positive results if the remaining cartilage was < 0,3 mm thick (n = 4), i. e. showed subchondral bone involvement. Contrast-to-noise ratio was significantly higher in MS-CT-air compared to MS-CT-CM. micro CT yielded a clear depiction of cartilage defect depth in the three cases. CONCLUSION: MS-CT-air has a high accuracy in the depiction of focal cartilage defects. MS-CT-CM has a tendency to overestimate cartilage defect depth. micro CT could potentially serve as alternative reference standard to histology.

Animals↗

[The role of angiography in the diagnosis and therapy of gastrointestinal hemorrhage].

PURPOSE: Evaluation of angiography in the diagnosis and treatment of acute and chronic gastrointestinal bleeding. MATERIALS AND METHODS: Thirty-seven consecutive patients with clinically suspected gastrointestinal bleeding underwent selective angiography of the visceral arteries. If technically possible, patients with radiologically proven hemorrhage underwent selective embolization with microcoils. Not all angiographically detected bleeding vessels were embolized. Clinical outcome was determined from a review of the medical records. RESULTS: 37 patients underwent 43 angiographies, which demonstrated 25 bleedings considered acute and 18 considered chronic. Seventeen patients had previous intestinal surgery. In 9 of the 37 patients, 12 of the 43 (sensitivity: 28 %) hemorrhages were detected. A postoperative bleeding was found in 6 patients. With one exception, all angiographically positive cases were clinically considered to be acute. Transcatheter embolization of the bleeding vessels with microcoils was performed in 6 patients, with 3 patients having the bleeding stopped permanently and 3 patients requiring further surgical treatment. In 3 patients, embolization was not possible for technical reasons. No complications attributable to angiography were seen. CONCLUSION: Angiography should be performed in patients with spontaneous and postoperative gastrointestinal bleeding. Transcatheter embolization is an effective and safe therapeutical option in both clinical settings.

Acute Disease↗