PubMed Health⌕ Search

Biomedical subjects

P G Datskos

Publications and source records attributed to P G Datskos.

8 recordsLinked to original sources

Enantioselective sensors based on antibody-mediated nanomechanics.

The use of microfabricated cantilevers as bioaffinity sensors was investigated. Since many bioaffinity interactions involve proteins as receptors, we conducted studies of the magnitude, kinetics, and reversibility of surface stresses caused when common proteins interact with microcantilevers (MCs) with nanostructured (roughened) gold surfaces on one side. Exposure of nanostructured, unfunctionalized MCs to the proteins immunoglobulin G and bovine serum albumin (BSA) resulted in reversible large tensile stresses, whereas MCs with smooth gold surfaces on one side produced reversible responses that were considerably smaller and compressive. The response magnitude for nanostructured MCs exposed to BSA is shown to be concentration dependent, and linear calibration over the range of 1-200 mg/L is demonstrated. Stable, reusable protein bioaffinity phases based on unique enantioselective antibodies are created by covalently linking monoclonal antibodies to nanostructured MC surfaces. The direct (label-free) stereoselective detection of trace amounts of an important class of chiral analytes, the alpha-amino acids, was achieved based on immunomechanical responses involving nanoscale bending of the cantilever. The temporal response of the cantilever (delta deflection/delta time) is linearly proportional to the analyte concentration and allows the quantitative determination of enantiomeric purity up to an enantiomeric excess of 99.8%. To our knowledge, this is the first demonstration of chiral discrimination using highly scalable microelectromechanical systems.

Amino Acids↗

An atomic force microscope-based investigation of vertical transport through GaAs/GaAlAs/InAlAs/GaAs step-barrier heterostructures.

Study of vertical transport through heterostructures consisting of single, double, or multiple quantum barriers is of both fundamental and technological interest. While extensive data regarding electron transport is available for single- and double-barrier structures, relatively less information is available for transport through step-barrier structures. In this paper, we present results from a study of room temperature vertical transport through a GaAs/GaAlAs/InAlAs/GaAs multistep-barrier heterostructure. A typical atomic force microscope has been adapted to perform transport measurements, thus allowing precise control of the physical location of the region of measurement. I-V measurements reveal negative differential resistance (NDR) peaks, thus confirming the formation of resonant states in a triangular well created when a voltage bias is applied across the step barrier. I-V curves have also been calculated by numerically solving the Schrödinger wave equation for this step-barrier structure. Comparison between the measured and calculated I-V curves shows reasonable agreement in the number of NDR peaks. However, discrepancies exist between the measured and calculated values for the voltages at which these NDR peaks occur. Some possible reasons for these discrepancies are discussed in this work.

Journal Article↗

Fabrication of quantum well microcantilever photon detectors.

We have developed a new method for fabricating quantum well microcantilever arrays that can be used in a variety of sensing applications. Microcantilevers with quantum wells allow real-time manipulation of energy states using external stress thus providing photon wavelength tunability. For example, this can result in an effective and rapid change in electron energy levels in photon detection devices. We applied this microfabrication technique to develop InSb microcantilevers and small arrays of GaAs/GaA1As microcantilever quantum wells. Such arrays can be useful in the detection of infrared (IR) radiation at room temperature.

Journal Article↗

Enhancing chemi-mechanical transduction in microcantilever chemical sensing by surface modification.

The use of chemically selective thin-film coatings has been shown to enhance both the chemical selectivity and sensitivity of microcantilever (MC) chemical sensors. As an analyte absorbs into the coating, the coating can swell or contract causing an in-plane stress at the associated MC surface. However, much of the stress upon absorption of an analyte may be lost through slippage of the chemical coatings on the MC surface, or through relaxation of the coating in a manner that minimizes stress to the cantilever. Structural modification of MC chemical sensors can improve the stress transduction between the chemical coating and the MC. Surfaces of silicon MC were modified with focused ion beam milling. Sub-micron channels were milled across the width of the MC. Responses of the nanostructured, coated MCs to 2,3-dihydroxynaphthalene and a series of volatile organic compounds (VOCs) were compared to smooth, coated MCs. The analytical figures of merit for the nanostructured, coated MCs in the sensing of VOCs were found to be better than the unstructured MCs. A comparison is made with a previously reported method of creating disordered nanostructured MC surfaces.

Journal Article↗

IR imaging using uncooled microcantilever detectors.

Uncooled bimaterial microcantilever detectors were fabricated and used to obtain infrared (IR) images of objects at temperatures ranging from room temperature to a few hundred degrees C. Images were obtained using both single 50 micro m x 50 micro m microcantilever IR detectors and arrays of microcantilever detectors. Thermal radiation from the target object was imaged onto the detector and the resulting temperature change caused microcantilever bending due to the bimaterial effect. This micromechanical bending was measured using two different non-contact optical readout techniques and IR images were obtained. A smaller size (20 micro m x 20 micro m) microcantilever IR detector was also used to capture IR images of near room temperature objects.

Journal Article↗

Detection and differentiation of biological species using microcalorimetric spectroscopy.

We report on the application of infrared (IR) microcalorimetric spectroscopy ( micro -CalSpec) to the identification and detection of trace amounts of biological species. Our approach combines principles of photothermal IR spectroscopy with ultrasensitive microcantilever (MC) thermal detectors. We have obtained photothermal IR spectra for DNA and RNA bases and for Bacillus Cereus (an anthrax simulant) in the wavelength range of 2.5-14.5 micro m (4000-690 cm(-1)). The measurements are accomplished by absorbing biological materials directly on a MC thermal detector. The main advantage of the developed micro -CalSpec is its unprecedented sensitivity as compared to any of the previously explored IR techniques, including FTIR and photothermal FTIR methods. Our results demonstrate that <10(-9)g of a biological sample is sufficient to obtain its characteristic micro -CalSpec spectrum that contains information-rich chemical (vibrational) signatures. This opens up a new opportunity to create inexpensive high-throughput analytical systems for biochemical detection.

Anthrax↗

Feasibility of tunable MEMS photonic crystal devices.

Periodic photonic crystal structures channel electromagnetic waves much as semiconductors/quantum wells channel electrons. Photonic bandgap crystals (PBC) are fabricated by arranging sub-wavelength alternating materials with high and low dielectric constants to produce a desired effective bandgap. Photons with energy within this bandgap cannot propagate through the structure. This property has made these structures useful for microwave applications such as frequency-selective surfaces, narrowband filters, and antenna substrates when the dimensions are on the order of millimeters. They are also potentially very useful, albeit much more difficult to fabricate, in the visible/near-infrared region for various applications when the smallest dimensions are at the edge of current micro-lithography fabrication tools. We micro-fabricated suspended free standing micro-structure bridge waveguides to serve as substrates for PBC features. These micro-bridges were fabricated onto commercial silicon-on-insulator wafers. Nanoscale periodic features were fabricated onto these micro-structure bridges to form a tunable system. When this combined structure is perturbed, such as mechanical deflection of the suspended composite structure at resonance, there can be a realtime shift in the material effective bandgap due to slight geometric alterations due to the induced mechanical stress. Extremely high resonance frequencies/device speeds are possible with these very small dimension MEMS.

Journal Article↗

Nanocantilever signal transduction by electron transfer.

Microfabricated cantilever beams promise to bring about a revolution in the field of chemical, physical, and biological sensor development. The resonance frequency of a microfabricated cantilever shifts sensitively because of mass loading from molecular adsorption. The minimum detectable adsorbed mass on a cantilever sensor can be increased by orders of magnitude by changing the dimensions of the device; smaller and thicker cantilevers offer higher resonance frequency and therefore better mass detection sensitivity. Here we describe micromachined silicon cantilevers that are 0.5 to 4 microns in length, fabricated with the use of a focused ion beam (FIB). In addition, we demonstrate a technique for detection of the cantilever resonance frequency that is based on electron transfer.

Crystallization↗