PubMed Health⌕ Search

Biomedical subjects

P G Schryver

Publications and source records attributed to P G Schryver.

4 recordsLinked to original sources

Analytic bias specifications based on the analysis of effects on performance of medical guidelines.

Laboratory tests are key indicators for certain practice guidelines, and analytic bias can significantly alter the performance of these guidelines. Three clinical paradigms are described: serum cholesterol testing for risk assessment of cardiac disease, serum thyroid-stimulating hormone (TSH) measurement for the detection of hypothyroidism, and serum prostate-specific antigen (PSA) testing for prostate cancer risk assessment. Maximum tolerance limits for analytic bias are calculated by assessing the subgroup population fluctuations in the number of patients exceeding the guideline threshold values and limiting the analytic bias to one-half of these fluctuations. Our calculated maximum bias limits are +/-1% for cholesterol and +/-6% for TSH and PSA. Our recommended +/-1% bias limit for cholesterol allows for a -6.5% to + 5.8% change in the number of patients designated as at risk for cardiac disease, whereas the +/-3% National Cholesterol Education Program limits permit a -18.4% to +16.7% variation. Similarly, our +/-6% bias limits for TSH allow a -17.7% to +26.6% change in patients flagged for hypothyroidism, whereas the +/-10% bias values found with many commercial reagents permit a -28.2% to +49.2% variation in patient classification. Our +/-6% PSA bias limits correspond to changes from -14.2% to +11.4% in the number of men classified as at risk for prostate cancer. The +/-10% bias ranges for PSA correspond to -19.9% to +20.4% variation in patient classification. The larger tolerance limits of the CLIA-88 standards for proficiency testing would cause even wider variations in patient classifications.

Cholesterol↗

Development and evaluation of an osteocalcin chemiluminoimmunoassay.

We developed a competitive chemiluminoimmunoassay of osteocalcin that is similar to radioimmunoassay but uses acridinium-ester-labeled antigen instead of 125I-labeled osteocalcin; a second antibody immobilized on plastic beads is used to separate free and bound fractions. There was good correlation of the new chemiluminoimmunoassay (y) with a polyclonal antiserum (R102) radioimmunoassay (x) used in many previous clinical studies (r = 0.96, y = 0.968x + 2.69, Sy/x = 0.029, n = 86). The new assay recognized both the intact and the small fragment of osteocalcin in plasma and detected decreases of them (total, approximately 47%) after a 24-h infusion of parathyroid hormone. Patients with primary hyperparathyroidism had increased concentrations of intact osteocalcin. Children had higher concentrations of osteocalcin than adults did. Healthy women had greater osteocalcin concentrations at ages 50-70 years than earlier. Inverse correlations of bone mineral density and osteocalcin were found in healthy women and in women with osteoporosis.

Adult↗

Multisite immunochemiluminometric assay for simultaneously measuring whole-molecule and amino-terminal fragments of human parathyrin.

The immunochemiluminometric assay described uses immobilized anti-human parathyrin (parathyroid hormone, hPTH)(1-44) and anti-hPTH(44-68) antisera and acridinium ester-labeled anti-hPTH(1-34) to simultaneously measure both intact hPTH and its amino-terminal fragments. Results by the assay correlate well with those by a cAMP-based bioassay and the Nichols Allegro immunoradiometric assay. The minimal detection limit is 0.08 pmol/L. The normal range is 1.0-5.0 pmol/L, and values are higher in older women. About 90% of study patients with surgically proven parathyroid adenomas had above-normal preoperative PTH concentrations, whereas patients with hypercalcemia of malignancy had normal or suppressed values. This assay was designed to detect both intact PTH and amino-terminal PTH fragments; however, chromatographic fractionation of pools of primary and secondary hyperparathyroid plasma showed virtually no amino-terminal fragment activity. Nonetheless, the design is important because the absence of carboxyl-terminal binding sites prevents interference by carboxyl-terminal fragments and because bioactive amino-terminal fragments will react in the assay if they are present in the patients' sera or if they are produced by in vitro proteolysis of intact PTH.

Chromatography↗

Improving performance in diabetes care: a multicomponent intervention.

CONTEXT: Compliance with recommendations from the American Diabetes Association for management of patients with diabetes is not optimal. Changing physician practice patterns with provider-focused interventions can be difficult. We report results after implementation of a type 2 diabetes mellitus guideline. OBJECTIVE: To increase the annual rate of microalbumin/urine protein testing, dilated eye examinations, and foot examinations for patients with diabetes and to reduce overall levels of hemoglobin A1c (Hb A1c). DESIGN: Before-after study. INTERVENTION: From April 1996 to June 1998, a guideline on type 2 diabetes mellitus was implemented with multicomponent interventions. These included small group educational sessions led by opinion leaders, an electronic version of the guideline, audit with feedback, and enhanced clinical orders support. Medical records of random samples of patients with diabetes were audited for specific diabetes performance measures on a monthly basis. Baseline data were compared with results at the end of the implementation effort. SETTING: Southeastern Minnesota, excluding Olmsted County. PARTICIPANTS: Adult patients seen at one practice of 18 general internists. OUTCOME MEASURES: Outcome measures included Hb A1c values and annual performance of a urine protein test, foot examination, and dilated eye examination. RESULTS: Gradual, sustained; and statistically significant improvements in the three annual performance measures were observed. Urine protein testing increased from 24% to 66% (P = 0.001), dilated eye examinations increased from 63% to 84% (P = 0.001), and foot examinations increased from 86% to 97% (P = 0.001). Mean Hb A1c values +/- SD also improved from 7.8% +/- 1.0% to 7.1% +/- 0.7% (P < 0.001) in patients who received continuing care for diabetes. CONCLUSIONS: Statistically significant improvements were observed after continuous improvement efforts were focused on providers in an individual group practice. When used to implement a diabetes guideline, such interventions may improve delivery of services and reduce Hb A1c levels in patients with diabetes.

Adult↗