Ethical issues in endoscopic surgery.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to P Geis.
Explore the source record for details and available documents.
PURPOSE: The intraoperative planning with peripheral loading approach is an important technique for ultrasound-guided transperineal prostate implant. In this paper a sphero-cylindrical dose model is described to generate a new power law or a look-up table for determination of the total (125)I activity required to deliver a prescription dose to a given prostate volume. METHODS AND MATERIALS: Dose calculations were based on the new standards for (125)I seeds (model 6711) implemented by the National Institute of Standards and Technology (NIST) in 1999. Using the sphero-cylindrical dose model with peripheral loading approach, a new power law for calculating total activity of radioactive iodine required to deliver a prescribed dose for the target volume was developed. Accounting for random variation of the seed positioning in the prostate and the current air-kerma strength standard of (125)I seeds, this new power law is formulated as follows: A (mCi) = 2.15 d (cm)(2.00) where A is apparent activity in mCi, or A (U) = 1. 69 d (cm)(2.00) where A is air-kerma strength in U, required to deliver a cumulative dose of 145 Gy to a prostate gland with an average dimension, d, in centimeters. RESULTS: The efficacy of using the new power law in prostate implants was demonstrated. For clinical evaluations of this new power law, 40 patients were chosen in 1998. The average D(90) of these 40 patients was 172.0 Gy (SD +/- 29 Gy). This means that on the average, 90% of the target volume received was 172.0 Gy. The average coverage index (CI) in this study was 94.7 (SD +/- 4.7). As a result, 94.7% of the target volume received the prescription dose. The dose homogeneity index (HI) which measured the degree of the dose inhomogeneity was 0.38 (SD +/- 0.21). CONCLUSION: This new and simple power law or a new mCi-volume look-up table for (125)I seed prostate implantation has been developed and formulated for clinical use. Clinical evaluations expressed in quantitative parameters such as D(90), CI, and HI in prostate implants have been thoroughly analyzed and clearly demonstrated the efficacy of this approach.
A preliminary study of the physical characteristics of a miniature multileaf collimator (mMLC) used with 4 MV x rays is reported. The mMLC attached to the accessory mount of a class C or D Varian linear accelerator (Varian Oncology Systems, Palo Alto, CA) with a source to aperture distance of 65 cm. The field penumbra using the small leaves was found to be consistent with the anticipated field penumbra using photon jaws at the same source to aperture distance as the mMLC. The percentage depth dose values of square fields were found to be consistent with the fields collimated with the upper and lower jaws. Output factors for the very small fields were found to vary rapidly. Circular fields could be produced with depth dose characteristics similar to those produced using conical tertiary collimators, commonly used for radiosurgery, but with a broader penumbra.
BACKGROUND: To determine if there are common factors beyond the learning curve that lead to recurrence after laparoscopic hernioplasty, we analyzed failures seen in seven centers specializing in laparoscopic hernia repair. METHOD: We performed a retrospective review of patients who had a laparoscopic hernioplasty (Tapp or Tep) between 1990 and 1996 at centers specializing in laparoscopic repairs (>500 repairs at each center). RESULTS: In all, 7661 patients had 10,053 hernias repaired by the transabdominal preperitoneal or the totally extraperitoneal approach; they were followed for 1 month to 6 years. In patients followed for >/=6 months with a median follow-up of 36 months, 35 repairs failed (0.4%), and all but one of these patients underwent a remedial operation. Twenty-nine had a laparoscopic repair, four had a combined laparoscopic and anterior repair, and one had an anterior repair alone. The cause of failure was determined in all 34 patients. The mechanism of recurrence was inadequate lateral fixation of the mesh in 11 cases, inadequate lateral fixation compounded by too small a mesh in three cases, missed lipoma of the cord in four cases, inadequate fixation of the mesh medially to Cooper's ligament in eight cases (seven of which were associated with too small a mesh), a missed hernia in four cases, and a hernia through a keyhole in the mesh in five cases. As surgeons gained experience, the incidence of recurrence due to missed hernias or too small a mesh decreased. CONCLUSIONS: This large multicenter study demonstrated that the incidence of recurrence after laparoscopic hernioplasty performed by experienced surgeons was extremely low and that some causes could be corrected by experience, whereas others will require changes in technique or equipment.
The Cyberknife is an image-guided "frameless" dedicated radiosurgical device. This instrument has several distinct advantages over frame-based systems, including improved patient comfort, increased treatment degrees of freedom, and the potential to target extracranial lesions. Clinical results thus far with respect to the treatment of malignant intracranial tumors has been promising. Additionally, the Cyberknife will likely revolutionize the application of radiosurgery to extracranial sites. A description of the components, treatment planning, and clinical results of the Cyberknife will be reviewed.
PURPOSE: The goal of modulated-beam conformal therapy is to reduce the dose to healthy tissue and sensitive structures around a uniformly irradiated target volume. Multiple intensity-modulated fields offer improved tissue-sparing dose distributions. New computer-based systems for planning and delivering such treatments may soon be available from different commercial sources that will make the formulation of an intensity-modulated treatment plan and its execution widely available at any treatment facility that has the resources to acquire the necessary equipment. This work reports on a study of the integration of two such systems. METHODS AND MATERIALS: Treatment planning was done using a commercially available inverse planning algorithm based on simulated annealing. The plans arbitrarily assumed nine coplanar x-ray beams at nonopposed gantry angles. Intensity modulation was computed for each beam. The modulated field at each gantry angle was broken down into a series of uniform (nonmodulated) subfields, which could be delivered as a sequence to produce the desired dose distribution. Because a large number of subfields was delivered, a multileaf collimator (MLC) was used for field shaping. This allowed rapid and accurate field shaping for treatments made up of several hundred subfields. Computer control of the MLC and linear accelerator allowed delivery of doses less than .01 Gy per subfield. Treatment was delivered on a prototype, computer-controlled accelerator and MLC system. Resulting dose distributions were analyzed using film and an anatomically specific, homogeneous phantom. RESULTS: The treatment plans were evaluated using dose-volume histogram analysis. The plans provided acceptably uniform irradiation of the target volume without exceeding dose tolerances for nearby critical structures. The plans were successfully delivered by a prototype dynamic MLC. The time needed to deliver a sequence of subfields at one gantry angle ranged from 0.7 to 2.0 min. Isodoses from film agreed reasonably well with planned isodose distributions. CONCLUSIONS: It is feasible to plan and deliver fixed gantry, modulated-beam conformal therapy for head and neck tumors with systems being developed commercially. The planned dose distributions exhibit significant potential for sparing closely spaced normal tissue structures in the head and neck.
PURPOSE: To estimate the dose delivered to patients by photons and neutrons outside the radiation fields when beam intensity modulation conformal radiotherapy is given. These estimates are then used to compute the risk of secondary cancers as a sequela of the radiation therapy. MATERIALS AND METHODS: The x-ray and neutron leakage accompanying two beam-intensity modulation techniques delivered by currently available linear accelerators were estimated for 6-MV, 18-MV, and 25-MV x-ray energies. Estimates of whole-body dose equivalents were determined using leakage measurements reported in the literature and treatment parameters derived for two modulated beam-intensity conformal therapy techniques. Risk values recommended by the National Council on Radiation Protection and Measurements (NCRP) were used to estimate the resulting risk of fatal radiation-induced cancer for 70.00 Gy prescribed tumor doses. RESULTS: The computed worst-case risks of secondary cancers increased in the range from 1.00% for 6-MV x-rays to 24.4% for 25-MV x-rays. CONCLUSIONS: Careful consideration should be made of the risks associated with secondary whole-body radiation before implementation of beam intensity modulated conformal therapy at x-ray energies greater than 10 MV.
The Cyberknife is a unique instrument for performing frameless stereotactic radiosurgery. Rather than using rigid immobilization, the Cyberknife relies on an image-to-image correlation algorithm for target localization. Furthermore, the system utilizes a novel, light-weight, high-energy radiation source. The authors describe the technical specifications of the Cyberknife and summarize the initial clinical experience.
A dynamic multileaf collimator (D-MLC) was used to investigate the feasibility of producing missing-tissue compensators. The modulation of the x-ray field in two dimensions produced by conventional physical compensators was mimicked by delivering a sequence of D-MLC-shaped subfields. A method is introduced to calculate monitor units (MU) for dynamically compensated fields that is analogous to and expands upon methods used for conventional compensating filter MU calculations. In this investigation, the tissue deficit at the surface of an anatomical phantom was measured using a Moiré camera. The tissue deficit data were used to generate a series of D-MLC subfields that, delivered in sequence, provided the compensated treatment. Film was used to integrate the dose delivered to a specified depth of compensation. Isodose distributions were measured for uncompensated fields, fields compensated with a conventional lead or plastic filter, and fields compensated with the D-MLC. A comparison of the dose distributions shows the compensation achieved with the dynamic compensating filter is comparable to that achieved using conventional physical compensating filters.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.