Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: comparison with carbon-11 epidepride and positron emission tomography.

Epidepride labelled with iodine-123 is a suitable probe for the in vivo imaging of striatal and extrastriatal dopamine D2 receptors using single-photon emission tomography (SPET). Recently, this molecule has also been labelled with carbon-11. The goal of this work was to develop a method allowing the in vivo quantification of radioactivity uptake in baboon brain using SPET and to validate it using positron emission tomography (PET). SPET studies were performed in Papio anubis baboons using 123I-epidepride. Emission and transmission measurements were acquired on a dual-headed system with variable head angulation and low-energy ultra-high resolution (LEUHR) collimation. The imaging protocol consisted of one transmission measurement (24 min, heads at 90 degrees), obtained with two sliding line sources of gadolinium-153 prior to injection of 0.21-0.46 GBq of 123I-epidepride, and 12 emission measurements starting 5 min post injection. For scatter correction (SC) we used a dual-window method adapted to 123I. Collimator blurring correction (CBC) was done by deconvolution in Fourier space and attenuation correction (AT) was applied on a preliminary (CBC) filtered back-projection reconstruction using 12 iterations of a preconditioned, regularized minimal residual algorithm. For each reconstruction, a calibration factor was derived from a uniform cylinder filled with a 123I solution of a known radioactivity concentration. Calibration and baboon images were systematically built with the same reconstruction parameters. Uncorrected (UNC) and (AT), (SC + AT) and (SC + CBC + AT) corrected images were compared. PET acquisitions using 0.11-0.44 GBq of 11C-epidepride were performed on the same baboons and used as a reference. The radioactive concentrations expressed in percent of the injected dose per 100 ml (% ID/100 ml) obtained after (SC + CBC + AT) in SPET are in good agreement with those obtained with PET and 11C-epidepride. A method for the in vivo absolute quantitation of 123I-epidepride uptake using SPET has been developed which can be directly applied to other 123I-labelled molecules used in the study of the dopamine system. Further work will consist in using PET to model the radioligand-receptor interactions and to derive a simplified model applicable in SPET.

Animals↗

A spline-regularized minimal residual algorithm for iterative attenuation correction in SPECT.

In SPECT, regularization is necessary to avoid divergence of the iterative algorithms used for non uniform attenuation compensation. In this paper, we propose a spline-based regularization method for the minimal residual algorithm. First, the acquisition noise is filtered using a statistical model involving spline smoothing so that the filtered projections belong to a Sobolev space with specific continuity and derivability properties. Then, during the iterative reconstruction procedure, the continuity of the inverse Radon transform between Sobolev spaces is used to design a spline-regularized filtered backprojection method, by which the known regularity properties of the projections determine those of the corresponding reconstructed slices. This ensures that the activity distributions estimated at each iteration present regularity properties, which avoids computational noise amplification, thus stabilizing the iterative process. Analytical and Monte Carlo simulations are used to show that the proposed spline-regularized minimal residual algorithm converges to a satisfactory stable solution in terms of restored activity and homogeneity, using at most 25 iterations, whereas the non regularized version of the algorithm diverges. Choosing the number of iterations is therefore no longer a critical issue for this reconstruction procedure.

Algorithms↗

Minimal residual cone-beam reconstruction with attenuation correction in SPECT.

This paper presents an iterative method based on the minimal residual algorithm for tomographic attenuation compensated reconstruction from attenuated cone-beam projections given the attenuation distribution. Unlike conjugate-gradient based reconstruction techniques, the proposed minimal residual based algorithm solves directly a quasisymmetric linear system, which is a preconditioned system. Thus it avoids the use of normal equations, which improves the convergence rate. Two main contributions are introduced. First, a regularization method is derived for quasisymmetric problems, based on a Tikhonov-Phillips regularization applied to the factorization of the symmetric part of the system matrix. This regularization is made spatially adaptive to avoid smoothing the region of interest. Second, our existing reconstruction algorithm for attenuation correction in parallel-beam geometry is extended to cone-beam geometry. A circular orbit is considered. Two preconditioning operators are proposed: the first one is Grangeat's inversion formula and the second one is Feldkamp's inversion formula. Experimental results obtained on simulated data are presented and the shadow zone effect on attenuated data is illustrated.

Algorithms↗

Three-dimensional PET reconstruction with time-of-flight measurement.

The interest in fully three-dimensional image reconstruction, especially in positron emission tomography (PET) has significantly increased for the last few years. Taking into account the cross-plane gamma rays in a three-dimensional reconstruction algorithm improves the sensitivity. At LETI, our specialty in PET is the time-of-flight (TOF) measurement. Thus, we present in this article two reconstruction techniques for 3D TOF PET. The first is a backprojection-convolution algorithm. Due to the redundancy in the 3D data set, there exists an infinite number of filters. As Defrise and co-workers did for classical tomography, we established a general condition that characterizes the filters and propose an algorithm with a factorizable filter. However, this first technique requires an acquisition system with revolution symmetry. Thus, we present a second one which is adapted to a detection geometry with a small number of angular positions. It consists of a multi-image deconvolution algorithm with Wiener filter.

Algorithms↗

Cone-beam SPECT with a tilted detector.

In this article we report on the TOMOCONIC project for cerebral SPECT using cone-beam collimators. First, we describe our experimental set-up. The cone-beam collimator improves both spatial resolution and sensitivity. We tilt the detector to center the focal point rotation plane on the region to reconstruct. Then, to minimize cone-beam artefacts, we use the Grangeat algorithm for image reconstruction. We describe here how it can be generated to this tilted acquisition geometry. Finally, we present our first experimental results and a comparison with parallel-beam SPECT. The improvement ratio on transverse spatial resolution is 1.5. We conclude with our first clinical images.