PubMed Health⌕ Search

Biomedical subjects

P H Alfille

Publications and source records attributed to P H Alfille.

6 recordsLinked to original sources

A quality improvement study of the placement and complications of double-lumen endobronchial tubes.

To assess the complications of conventional and fiberoptic endobronchial intubations using reusable (Leyland, London) and disposable (Rüsch, Waiblinger, Germany; Sheridan, Argyle, NY) double-lumen tubes (DLTs), endobronchial intubations occurring over a 12-month period were prospectively studied at this hospital. Residents working with staff anesthesiologists placed either left or right reusable (Leyland) or disposable (Rüsch or Sheridan) DLTs. The DLT used, the use of fiberoptic bronchoscopy (FOB), findings at FOB if used during the intubation or operation, and complications occurring during the case (SpO2 < 90%, peak inflation pressure > 40 cm H2O, air trapping, poor lung isolation, and airway trauma) were recorded. Two hundred thirty-four intubations were analyzed (102 right, 132 left; 70 Leyland reusable DLTs, 66 Rüsch disposable tubes, and 98 Sheridan tubes). Physical signs alone were used to confirm tube position more frequently when Leyland tubes were placed compared with disposable tubes (79% v 39%, P < 0.0001). Rüsch and Sheridan DLTs had similar rates of conventional placement. Nineteen percent of reusable tubes and 44% of disposable tubes required position adjustments using FOB during the initial intubation (P = 0.0002). Disposable tubes also more commonly required readjustment using FOB during the operation (30% v 7%, P < 0.0005). Complications occurred in 42/234 patients (18%). The frequency of specific complications was: decreased SpO2, 9%; increased airway pressures, 9%; poor lung isolation, 7%; air trapping, 2%, and airway trauma, 0.4%. Right-sided Sheridan DLTs had a statistically higher incidence of malposition, resulting in poorer lung isolation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Comparison of thoracic and lumbar epidural infusions of bupivacaine and fentanyl for post-thoracotomy analgesia.

Epidural analgesia, via either a thoracic or lumbar route, is commonly used to provide postoperative analgesia following thoracotomy for pulmonary resection, but little data indicate which location is better in terms of postoperative analgesia, side effects, or associated complications. In this study, 45 patients, who were scheduled to have epidural analgesia and undergo a lateral thoracotomy, were randomized to receive either a thoracic or a lumbar catheter. Pain assessments and routine clinical data were recorded to determine if either thoracic or lumbar epidural catheters provided superior analgesia, fewer side effects, or fewer complications. This study found no statistical difference in pain relief or side effects between lumbar and thoracic epidural analgesia for post-thoracotomy pain. An increased infusion rate (6.4 +/- 1.9 v 5.1 +/- 1.4 mL/h, P = 0.02) was required in the lumbar group to achieve equivalent analgesic levels.

Adult↗

Airway obstruction following application of cricoid pressure.

The widely practiced rapid-sequence induction with application of cricoid pressure is designed to facilitate endotracheal intubation in patients considered to be at high risk of aspiration. We describe a case in which this maneuver was performed on a patient with an undiagnosed traumatic injury to the larynx. The resulting airway obstruction required emergency surgical intervention. The clinical presentation, diagnosis, and management of such injuries are discussed.

Adult↗