PubMed Health⌕ Search

Biomedical subjects

P H Arger

Publications and source records attributed to P H Arger.

At least 19 recordsLinked to original sources

Diffuse boundary extraction of breast masses on ultrasound by leak plugging.

We propose a semiautomated seeded boundary extraction algorithm that delineates diffuse region boundaries by finding and plugging their leaks. The algorithm not only extracts boundaries that are partially diffuse, but in the process finds and quantifies those parts of the boundary that are diffuse, computing local sharpness measurements for possible use in computer-aided diagnosis. The method treats a manually drawn seed region as a wellspring of pixel "fluid" that flows from the seed out towards the boundary. At indistinct or porous sections of the boundary, the growing region will leak into surrounding tissue. By changing the size of structuring elements used for growing, the algorithm changes leak properties. Since larger elements cannot leak as far from the seed, they produce compact, less detailed boundary approximations; conversely, growing from smaller elements results in less constrained boundaries with more local detail. This implementation of the leak plugging algorithm decrements the radius of structuring disks and then compares the regions grown from them as they increase in both area and boundary detail. Leaks are identified if the outflows between grown regions are large compared to the areas of the disks. The boundary is plugged by masking out leaked pixels, and the process continues until one-pixel-radius resolution. When tested against manual delineation on scans of 40 benign masses and 40 malignant tumors, the plugged boundaries overlapped and correlated well in area with manual tracings, with mean overlap of 0.69 and area correlation R2 of 0.86, but the algorithm's results were more reproducible.

Algorithms↗

Interreader variability and predictive value of US descriptions of solid breast masses: pilot study.

RATIONALE AND OBJECTIVES: This study evaluated the specificity of ultrasound (US) characteristics of solid breast lesions and the interreader variability in their interpretation. MATERIALS AND METHODS: In 61 patients, 70 sonographically visible solid masses, scheduled for biopsy because of findings from conventional imaging, were prospectively and sequentially accrued for evaluation. Three readers interpreted the sonograms and described the solid masses in terms of established US characteristics. The specificity and positive predictive value (PPV) for each characteristic were calculated by comparing US findings with biopsy findings, and interreader variability was evaluated. Five assessment categories were developed to guide recommendations for patient care. The relative performance of each reader was assessed by measuring the PPV for each assessment category and by measuring the area under the receiver operating characteristic curve. RESULTS: The specificity and PPV were calculated for all characteristics and for each reader. The average specificities of the three readers for the most frequently used six characteristics were as follows: spiculation, 97%+/-5 (standard deviation); taller than wide, 91%+/-4; central shadowing, 77%+/-1; markedly hypoechoic, 86%+/-5; duct extension, 95%+/-5; and microlobulation, 84%+/-3 (overall average specificity, 88.5%). The average PPVs for categories II-V were 5%, 10%, 63%, and 94%, respectively. The readers' interpretations were similar and correlated well. CONCLUSION: The proposed US recommendation system is an accurate predictor of histologic findings. A sonographic classification lexicon should prove valuable.

Breast↗

Renal blood flow changes induced with endothelin-1 and fenoldopam mesylate at quantitative Doppler US: initial results in a canine study.

PURPOSE: To evaluate quantitative Doppler ultrasonography (US) for assessing renal blood flow changes induced with endothelin-1 (ET-1) and fenoldopam mesylate in conscious dogs. MATERIALS AND METHODS: A blood flow probe was surgically implanted around the renal artery in eight adult dogs. Color and power Doppler US images were acquired in conscious restrained dogs during intravenous infusion of ET-1 and fenoldopam mesylate. Simultaneous with imaging, blood flow through the renal artery was measured with the implanted probe. The color level of the images within the region representing the kidney was analyzed to derive flow indices. These indices were compared with direct-flow measurements. RESULTS: The flow indices, color-weighted flow area (CWFA), and percentage of area of color, derived from color and power Doppler US images, correlated linearly with direct flow. The mean color level of color and power Doppler US images correlated weakly with direct flow. Pre- versus postinfusion CWFA decreased with all ET-1 infusions (P < or =.032). Infusion of fenoldopam mesylate increased CWFA in all cases (P < or =.032). CONCLUSION: Quantitative Doppler US enabled successful measurement of the flow changes induced with ET-1 and fenoldopam mesylate. Quantitative Doppler US is potentially useful as a noninvasive surrogate endpoint in evaluating the action of various therapeutic agents.

Animals↗

Quantitative vascularity of breast masses by Doppler imaging: regional variations and diagnostic implications.

Seventy-four biopsy proven breast masses were imaged by color and power Doppler imaging to evaluate vascular pattern of malignant and benign breast masses. The images were analyzed for vascularity. The measurements were made over the entire mass as well as regionally at its core, at its periphery, and in the tissue surrounding it. The surgical specimens were analyzed for microvessel density. The diagnostic performance of Doppler sonographic vascularity indices was evaluated by receiver operating characteristic analysis. The malignant masses were 14 to 54% more vascular than the benign masses. Both types of masses were more vascular by ultrasonography than the tissue surrounding them. Whereas benign masses were 2.2 times more vascular than the surrounding tissue, the malignant masses were 5.0 times more vascular. In a subset of patients the regional vascularity at the core, periphery, and surrounding tissue by Doppler imaging exhibited a strong correlation (R2 > 0.9) with the corresponding histologic microvessel density measurements. Although the malignant masses exhibited a strong gradient in vascularity, core > periphery > surrounding tissue, the benign masses had relatively uniform distribution of vascularity. The area under the receiver operating characteristic curve (A(Z)) for the Doppler indices ranged from 0.56 +/- 0.07 to 0.65 +/- 0.07. A nonlinear analysis including age-specific values of Doppler indices improved the diagnostic performance to A(Z) = 0.85 +/- 0.06. In conclusion, quantitative Doppler imaging when used in combination with a nonlinear rule-based approach has the potential for differentiating between malignant and benign masses.

Adult↗

Diagnosis and staging of ovarian cancer: comparative values of Doppler and conventional US, CT, and MR imaging correlated with surgery and histopathologic analysis--report of the Radiology Diagnostic Oncology Group.

PURPOSE: To determine the optimal imaging modality for diagnosis and staging of ovarian cancer. MATERIALS AND METHODS: Two hundred eighty women suspected to have ovarian cancer were enrolled in a prospective study before surgery. Doppler ultrasonography (US), computed tomography (CT), and magnetic resonance (MR) imaging were used to evaluate the mass; conventional US, CT, and MR imaging were used to stage spread. RESULTS: All three modalities had high accuracy (0.91) for the overall diagnosis of malignancy. In the ovaries, the accuracy of MR imaging (0.91) was higher than that of CT and significantly higher than that of Doppler US (0.78). In the extraovarian pelvis and in the abdomen, conventional US, CT, and MR imaging had similar accuracies (0.87-0.95). In differentiation of disease confined to the pelvis from abdominal spread, the specificity of conventional US (96%) was higher than that of CT and significantly higher than that of MR imaging (88%), whereas the sensitivities of MR imaging (98%) and CT (92%) were significantly higher than that of conventional US (75%). CONCLUSION: MR imaging is superior to Doppler US and CT in diagnosis of malignant ovarian masses. There is little variation among conventional US, CT, and MR imaging as regards staging.

Adult↗

Sonography during early pregnancy: dependence of threshold and discriminatory values on transvaginal transducer frequency.

OBJECTIVE: Our goal was to determine if normal and abnormal pregnancies could be distinguished at smaller sac sizes with a higher frequency transvaginal transducer than with a 5-MHz transducer. SUBJECTS AND MATERIALS: Thirty-nine patients with potentially abnormal pregnancies identified with a 5-MHz transvaginal transducer were immediately reimaged with a 9-5-MHz transducer. We compared our ability to visualize the yolk sac, embryo, and cardiac activity relative to mean sac diameter on imaging at both frequencies in women with normal and abnormal pregnancies. RESULTS: Of the 39 pregnancies, 22 (56%) were normal or probably normal. Using the 5-MHz transducer, a yolk sac was first seen in a 6.4-mm gestational sac but was not definitively seen in 12 gestational sacs measuring 5-13 mm. Using the 9-5-MHz transducer, yolk sacs were identified in all gestational sacs measuring 4.6-13 mm, and live embryos were seen in five of eight sacs measuring 8.1-13 mm. The largest normal gestational sac without a live embryo measured 11 mm. When we compared these pregnancies with 17 (44%) abnormal pregnancies, we found that all pregnancies that had no yolk sac by the time the gestational sac measured 5.0 mm or no live embryo by 13 mm had abnormal findings on higher frequency imaging. CONCLUSION: The ability to visualize the yolk sac and embryo in early pregnancy is critically dependent on transvaginal transducer frequency. Threshold values and discriminatory sizes used to distinguish normal and abnormal pregnancies are smaller on higher frequency than on lower frequency imaging and, therefore, should be redetermined for specific transducer frequencies.

Adolescent↗

Evaluation of change in blood flow by contrast-enhanced power Doppler imaging during norepinephrine-induced renal vasoconstriction.

We evaluated the changes in flow induced by intrarenal infusion of norepinephrine by an ultrasonographic contrast agent and power Doppler imaging. Hypoperfusion was induced in dogs (N = 5) by infusing norepinephrine directly into the renal artery for 30 min at doses of 0.7 microg/kg/min, 1.0 microg/kg/min, and 1.9 microg/kg/min. Contrast agent injections were made before and after each infusion of norepinephrine. The transit of contrast agent through the kidney and color enhancement were measured by computer analysis of power Doppler images. Mean transit time and effective renal plasma flow were measured. The effective renal plasma flow decreased by 29%, 30%, and 64%, respectively, with the increasing doses of norepinephrine. Paralleling this change, the mean transit time, which corresponds to reduction in renal blood flow, increased by 26%, 43%, and 77%, respectively, from the preinfusion value. Regression analysis shows renal blood flow to decrease exponentially with norepinephrine dose. Renal blood flow changes measured by contrast-enhanced imaging correlated closely with the effective renal plasma flow measurements. Computer analysis of contrast-enhanced power Doppler images allowed measurement of renal blood flow. This technique may be useful in assessing renal perfusion during pharmacologic and other therapeutic interventional procedures.

Animals↗

Comparison of power Doppler and B-scan sonography for renal imaging using a sonographic contrast agent.

The goal of this study was to evaluate the relative performance of power Doppler and B-scan imaging modes in detecting vascular perfusion changes resulting from injection of a contrast agent. To allow this comparison the imaging plane and the contrast agent injection must be the same for both modes. We achieved this by using a rigid transducer holder and simultaneously recording power Doppler and B-scan images on separate videotapes. The kidneys of five adult beagles were scanned to allow a comparison of how power Doppler and B-scan imaging methods monitor changes during the injection of 0.1 ml/kg of a contrast agent, EchoGen emulsion (Sonus Pharmaceuticals, Bothell, WA). The changes in the images were assessed qualitatively by three radiologists and quantitatively using a custom-designed image analysis software. All of the radiologists agreed that no visually detectable changes occurred in B-scan images but that significant changes could be observed in power Doppler images. Image analysis also indicated a difference between power Doppler and B-scan images. The change in mean color level of power Doppler images could be displayed as an indicator dilution curve with a peak enhancement of 46 +/- 16 above the preinjection value. The time at which mean color level peaked was 18 +/- 13 s. The mean color level returned to half of the peak value by 69 +/- 42 s and returned to the preinjection baseline value by 148 +/- 73 s. Conversely, B-scan images showed statistically insignificant changes, and time measurements could not be made. By all measures used to evaluate images, power Doppler imaging had a greater sensitivity in detecting changes resulting from contrast agent injection than B-scan imaging. This finding indicates that power Doppler imaging of contrast agent injections can be used to map regional differences in flow as well as quantitative measurements of a contrast agent's transit time and has the potential to assess kidney abnormalities associated with renal blood flow.

Animals↗

First-trimester US parameters of failed pregnancy.

PURPOSE: To test the reliability of established ultrasound (US) parameters in predicting the outcome of first-trimester pregnancy. MATERIALS AND METHODS: The authors retrospectively reviewed 2,655 first-trimester US scans in 2,285 patients. Parameters tested against outcome were (a) a yolk sac and mean gestational sac diameter of 8 mm on transvaginal US scans, (b) an embryo and mean sac diameter of 16 mm on transvaginal US scans, and (c) a difference between the mean sac diameter and crown-rump length of less than 5 mm (oligohydramnios) at 5.5-9.0 weeks gestation. RESULTS: Thirty (22%) of 135 patients without yolk sacs and with an 8-mm mean sac diameter developed live embryos: 24 had normal follow-up or delivery; six were lost to follow-up. Five (8%) of 59 patients with no depiction of embryos and with a 16-mm mean sac diameter developed live embryos: Two delivered, one spontaneously aborted, one had death of one twin embryo before being lost to follow-up, and one was lost to follow-up. Seventeen (0.74%) of 2,285 patients had early oligohydramnios: Six (35%) had normal follow-up scans or delivery, two (12%) spontaneously aborted, and nine (53%) were lost to follow-up. CONCLUSION: Established parameters predictive of early pregnancy failure potentially result in misdiagnosis of nonviability or poor prognosis when applied to a large, unselected patient population. Close follow-up is necessary in cases with borderline abnormal findings.

Abortion, Spontaneous↗

Mathematical modeling of the dilution curves for ultrasonographic contrast agents.

Most techniques using sonographic contrast agents are based on introducing the agent intravenously. The sonographic changes occur over time and follow a characteristic "skewed gaussian curve," often referred to as the indicator dilution curve. This study uses principles of linear acoustics and tracer kinetics to develop a quantitative model for the indicator dilution curve. A rapid increase in image brightness occurs after bolus injection; brightness peaks after a time related to the blood flow and stability of the contrast agent, which is followed by an asymptotic decrease in image brightness. The net image enhancement, represented by the area under the dilution curve, increases nonlinearly with the injected dose. In stable contrast agents the peak-time and mean transit time are related directly to the flow rate. This relationship changes when the microbubbles of a contrast agent collapse. In an unstable contrast agent the indicator dilution curve is attenuated and peaks earlier than expected on the basis of flow rate. The extent of shift in the mean transit time varies with the half-life of the contrast agent and follows a sigmoid relationship. In conclusion, the properties of the time-videointensity (indicator dilution) curves are significantly affected by the attenuation and stability of the contrast agents. These factors must be taken into consideration in deriving flow related information.

Absorption↗

Power, spectral, and color flow Doppler enhancement by a new ultrasonographic contrast agent.

The ability of EchoGen contrast agent (Sonus Pharmaceuticals, Bothell, WA) to enhance aortic, renal, and scrotal spectral Doppler, color flow, and power Doppler sonography at doses from 0.01 ml/kg to 0.65 ml/kg was evaluated in dogs. Videotaped images were digitized and analyzed for Doppler signal strength at known postinjection times. Contrast agent increased aortic spectral Doppler peak height, spectral width, and brightness. Contrast agent increased renal and testicular color flow and power Doppler sonographic signal and enhanced the visualization of vascular anatomy. Intensity and duration of these effects increased with increasing dose of contrast agent. Enhancement effect varied in different organs. At higher doses, blooming and Doppler shift artifacts were observed and are believed to be due to machine limitation.

Animals↗

Strategy for repeat biopsy of patients with prostatic intraepithelial neoplasia detected by prostate needle biopsy.

PURPOSE: We evaluated the strategy for repeat biopsy of patients with prostatic intraepithelial neoplasia without concurrent carcinoma detected on prostate needle biopsy. MATERIALS AND METHODS: Of 1,275 consecutive patients undergoing prostate needle biopsy 61 were identified with prostatic intraepithelial neoplasia but without concurrent prostate carcinoma. Of the 61 patients 53 had undergone repeat biopsy. The medical records, transrectal ultrasound, and operative and pathological reports of these patients were reviewed. RESULTS: Repeat biopsy was done in 53 patients with prostatic intraepithelial neoplasia, yielding carcinoma in 15, prostatic intraepithelial neoplasia without carcinoma in 8 and benign tissue in 30. The yield of carcinoma from repeat biopsy of a prostatic intraepithelial neoplasia site was 8.3% (7 of 84 sites). A total of 18 sites of carcinoma was detected by repeat biopsy of a previous random biopsy site (8), a prostatic intraepithelial neoplasia site only (5), a transrectal ultrasound nodule (3), a palpable nodule and prostatic intraepithelial neoplasia site (1), and a transrectal ultrasound nodule and prostatic intraepithelial neoplasia site (1). Carcinoma was as frequently detected by repeat biopsy of a prostatic intraepithelial neoplasia site (6 patients) as by random repeat biopsy (6 patients). CONCLUSIONS: Repeat prostate needle biopsy of patients with prostatic intraepithelial neoplasia should include random repeat biopsy and repeat biopsy of transrectal ultrasound abnormalities as well as previous sites of prostatic intraepithelial neoplasia.

Adenocarcinoma↗

Influence of postprocessing curves on contrast-echographic imaging: preliminary studies.

The aim of this study was to evaluate the influence of postprocessing curves on the visual and quantitative enhancement of image brightness caused by the injection of a contrast agent. A fixed dose (0.45 ml/kg) of contrast agent EchoGen was injected into three dogs, and images of the kidney were investigated using one linear (A) and three nonlinear (B, C, D) postprocessing curves. Curve D gave the best gray scale images and was generally used for diagnostic imaging. Images were analyzed qualitatively in three dogs and quantitatively in one dog for brightness change caused by contrast agent injection. Visually the changes were most identifiable with curve C and least by curve D. Video intensity time curves reflected the qualitative changes. Peak contrast and area under the video density curve changed in the order curve D < curve B approximately curve A < curve C. Choice of the postprocessing curve can have a marked influence on the enhancement of image brightness by a contrast agent. Postprocessing curves optimized to display a wide range of echo levels may not always be an ideal choice for contrast sonography.

Animals↗

Sonographic enhancement of renal cortex by contrast media.

The purpose of this study was to evaluate whether a phase shift contrast agent could enhance the renal cortex. Four doses of the contrast agent EchoGen ranging from 0.25 to 0.65 ml/kg were injected intravenously in three healthy dogs. Images of the kidney were recorded on a videotape before and after each injection. The images were evaluated visually and were computer-analyzed for brightness change caused by the contrast agent. Marked changes in cortical brightness were observed at the doses of 0.45 and 0.65 ml/kg. At lower doses the changes in image brightness were significantly reduced but measurable. The brightness peaked at 65 +/- 9 seconds after injection and gradually decreased to the baseline value in approximately 12 minutes. The video density varied nonlinearly with dose, and at low doses its value drifted below the baseline. This is believed to be due to attenuation of echoes by the contrast agent. The results of this study indicate that the microbubbles formed by phase shift contrast media are sufficiently small and persist long enough to enhance sonographic images of the cortex. Contrast media whose effect is based on the phenomenon of phase shift permit enhancement of the gray scale characteristic of the kidney. The enhancements last up to several minutes and have strong potential to allow investigation of perfusion in kidney.

Animals↗

Pancreatic sparing of focal fatty infiltration.

PURPOSE: To describe typical findings of focal fatty sparing of the pancreas. MATERIALS AND METHODS: Computed tomography, ultrasonography, and/or magnetic resonance imaging were performed in seven patients. RESULTS: In these patients, the area of sparing of fatty change was within the head or uncinate process of the pancreas. CONCLUSION: Differentiating pancreatic fatty sparing from true neoplasm by means of cross-sectional imaging obviates the need for invasive diagnostic studies.

Adipose Tissue↗

Emergency department screening for ectopic pregnancy: a prospective US study.

PURPOSE: To determine the effectiveness of pelvic sonography as a screening test for ectopic pregnancy. MATERIALS AND METHODS: Pelvic sonograms were prospectively analyzed in 1,427 consecutive patients with a serum level of the beta subunit of human chorionic gonadotropin of over 1,500 IU/L. RESULTS: Sonograms were diagnostic in 1,158 patients and indeterminate in 269. When indeterminate studies were considered falsely negative, the diagnostic accuracy was 81%. Twenty-four percent of patients with indeterminate studies were subsequently proved to have ectopic pregnancy. In ectopic pregnancy (n = 103), the most common finding was a complex adnexal mass (specificity = 92% [P < .001]). The sensitivity and specificity of screening sonography for ectopic pregnancy were 99% and 84%, respectively. CONCLUSION: Pelvic sonography is an effective screening test for ectopic pregnancy. Having a one in four chance of harboring an ectopic pregnancy, patients with indeterminate studies require close follow-up. The presence of a complex adnexal mass is a strong predictor of ectopic pregnancy.

Adult↗