PubMed Health⌕ Search

Biomedical subjects

P H Simkin

Publications and source records attributed to P H Simkin.

5 recordsLinked to original sources

Effect of various doses of recombinant human thyrotropin on the thyroid radioactive iodine uptake and serum levels of thyroid hormones and thyroglobulin in normal subjects.

Recombinant human TSH (rhTSH), usually given as 0.9-mg doses im on 2 successive days, increases serum thyroglobulin (Tg) and radioactive iodine uptake (RAIU) in residual thyroid tissue in patients with thyroid cancer. We previously reported that a single, relatively low dose of rhTSH (0.1 mg im) is a potent stimulator of T(4), T(3), and Tg secretion in normal subjects. The present study describes the effects of higher doses of rhTSH on thyroid hormone and Tg secretion. Six normal subjects for each dose group, having no evidence of thyroid disease, received either 0.3 or 0.9 mg rhTSH by im injection. Serum TSH, T(4), T(3), and Tg concentrations were measured at 2, 4, and 8 h and 1, 2, 3, 4, and 7 days after rhTSH administration. The peak serum TSH concentrations were 82 +/- 18 and 277 +/- 89 mU/L, respectively, for the 0.3- and 0.9-mg doses of rhTSH. Serum T(4), T(3), and Tg concentrations increased significantly in subjects receiving 0.3 and 0.9 mg rhTSH, with significant increases in T(4) and T(3) being observed before significant increases in serum TG: Peak concentrations of serum T(4), T(3), and Tg, after 0.3 mg rhTSH administration, were 100 +/- 19, 131 +/- 14, and 1035 +/- 724% above individual baselines, respectively. Similarly, peak concentrations of serum T(4), T(3), and Tg, after 0.9 mg rhTSH administration, were 102 +/- 16, 134 +/- 7, and 1890 +/- 768% above individual baselines, respectively. These data, compared with previously reported data for the responses to 0.1 mg rhTSH, indicated that 0.1, 0.3, and 0.9 mg rhTSH had similar quantitative stimulatory effects on thyroid hormone and Tg secretion, except that the T(4) response was greater in groups receiving 0.3 and 0.9 mg rhTSH than in the group receiving 0.1 mg rhTSH. We also studied the effect of rhTSH on the thyroid RAIU in the group that received 0.9 mg rhTSH. The 6- and 24-h RAIU values were significantly higher after rhTSH (pre-rhTSH, 6-h value = 12.5 +/- 1.8%; 24 h value = 23 +/- 2.7%; post-rhTSH, 6 h value = 27 +/- 4.8%; 24-h value = 41 +/- 4.2%). The stimulating effects of 0.9 mg rhTSH on the 6- and 24-h RAIUs were similar. rhTSH is a potent stimulator of T(4), T(3), and Tg secretion and the RAIU in normal subjects. Single doses greater than 0.1--0.3 mg do not seem to further enhance thyroid hormone or Tg secretion.

Adult↗

Comparing filtered backprojection and ordered-subsets expectation maximization for small-lesion detection and localization in 67Ga SPECT.

UNLABELLED: Iterative reconstruction of SPECT images has recently become clinically available as an alternative to filtered backprojection (FBP). However, there is conflicting evidence on whether iterative reconstruction, such as with the ordered-subsets expectation maximization (OSEM) algorithm, improves diagnostic performance over FBP. The study objective was to determine if the detection and localization of small lesions in simulated thoracic gallium SPECT images are better with OSEM reconstruction than with FBP, both with and without attenuation correction (AC). METHODS: Images were simulated using an analytic projector acting on the mathematic cardiac torso computer phantom. Perfect scatter rejection was assumed. Lesion detection accuracy was assessed using localization receiver operating characteristic methodology. The images were read by 5 nuclear medicine physicians. For each reconstruction strategy and for each observer, data were collected in 2 viewing sessions of 100 images. Two-way ANOVA and, when indicated, the Scheffé multiple comparisons test were applied to check for significant differences. RESULTS: Little difference in the accuracy of detection or localization was seen between FBP with and without AC. OSEM with AC extended the contrast range for accurate lesion detection and localization over that of the other methods investigated. Without AC, no significant difference between OSEM and FBP reconstruction was detected. CONCLUSION: OSEM with AC may improve the detection and localization of thoracic gallium-labeled lesions over FBP reconstruction.

Algorithms↗

Monomorphic teratoma of the ovary: a rare cause of triiodothyronine toxicosis.

A case of low thyroid radioactive iodine uptake (RAIU) thyrotoxicosis due to a large struma ovarii comprising pure thyroid tissue is presented, including a detailed diagnostic evaluation, histopathology, and demonstration of rapid recovery of native thyroid function after surgical excision. In addition, the first comprehensive analysis of thyroglobulin obtained from an ovarian struma is reported.

Aged↗

Effect of filtering on the detection and localization of small Ga-67 lesions in thoracic single photon emission computed tomography images.

Tumor detection can be significantly affected by filtering so determining an optimal filter is an important aspect of establishing a clinical reconstruction protocol. The purpose of this study was to identify the cut-off frequency of a Butterworth filter used in a filtered backprojection (FBP) reconstruction that maximized the detection and localization accuracy of 1 cm spherical lesions in Ga-67 citrate, thoracic SPECT images. Image quality was evaluated by means of a localization receiver operating characteristic (LROC) study using computer simulated images. Projection data were generated using the mathematical cardiac-torso digital phantom with a clinically realistic background source distribution. The images were reconstructed using FBP with multiplicative Chang attenuation correction and fifth-order Butterworth filtering. The cut-off frequencies considered were 0.25, 0.32, 0.47, and 0.79 cm(-1) for the case of three-dimensional (3D) post-filtering and 0.25, 0.32, and 0.47 cm(-1) for two-dimensional (2D) post-filtering. The images were read by three research scientists and one board certified nuclear medicine clinician. The area under the LROC curve and the localization accuracy for all test conditions were compared using Scheffé's multiple comparisons test. It was found that 3D post-filtering using filters with cut-off frequencies of 0.32 and 0.47 cm(-1) resulted in the highest lesion detectability and localization accuracy. These two test conditions did not differ significantly from each other but were significantly better (p<0.05) than all of the 2D, and the 3D 0.79 cm(-1) cut-off frequency cases.

Analysis of Variance↗

Pulmonary nuclear medicine.

The major nuclear medicine contribution to the pulmonary imaging literature for the past year was the inaugural report from the Prospective Investigation of Pulmonary Embolism Diagnosis study. Investigations focusing on the role of thrombolytic agents for the management of pulmonary thrombosis have advanced to the stage in which different therapeutic regimens are being tested along with new agents that continue to emerge. Ongoing research and clinical trials are evaluating newer radiolabeled aerosols in patients with airways and interstitial lung disease using imaging and clearance measurements. Positron-emission tomography continues to be utilized in a few research centers for tumor localization and characterization.

Humans↗