High-efficiency multiplex capillary electrophoresis single strand conformation polymorphism (multi-CE-SSCP) mutation screening of SCN5A: a rapid genetic approach to cardiac arrhythmia.

Mutations in the SCN5A gene coding for the alpha-subunit of the cardiac Na(+) ion channel cause long QT syndrome, Brugada syndrome, idiopathic ventricular fibrillation, sick sinus node syndrome, progressive conduction disease, dilated cardiomyopathy and atrial standstill. These diseases exhibit variable expressivity, and identification of gene carriers is clinically important, particularly in sudden infant and adult death syndromes. The SCN5A gene comprises 28 exons distributed over 100 kbp of genomic sequence at chromosome 3p21. Disease-causing mutations are private and scattered over the DNA sequence, making it difficult to screen for specific mutations. We developed a multiplex capillary-electrophoresis single-strand conformation polymorphism (Multi-CE-SSCP) mutation screening protocol on the ABI 3100 platform and applied it to 10 previously slab-gel SSCP identified mutations and SNPs and used it to identify one novel deletion. The method is highly efficient, with a turnover of 23 patients per 24 h and a false positive rate of 0.5% of the analyzed amplicons. Each variant has a particular elution pattern, and all 20 carriers of the H558R polymorphism out of 57 persons were correctly identified. We suggest that the method could become part of routine work-up of patients with suspicious syncope and of members of families with sudden unexplained death.

Amino Acid Substitution↗

Automated quality assurance and patient dosimetry in diagnostic radiology.

It has been generally considered that improved methods of quality assurance would reduce the population dose from diagnostic radiology. This paper describes the development of a computerized method of automatically monitoring tube and generator parameters to perform on-line quality assurance, whilst undertaking various patient dosimetry measurements and calculations for each exposure. The method involves interfacing a microcomputer to a microprocessor controlled X-ray generator. Details of the various interfacing methods and modifications to the X-ray unit are given. The instrument enables quality assurance to be performed for every exposure by comparing tube and generator parameters against nominal settings. The software automatically warns the operator of any deviations from accepted limiting values. When a patient is examined, details of the examination and projection are entered into a database. The exposure area product and field size are monitored for each exposure. This data, together with information on tube potential and examination/projection is used to deduce patient entrance skin dose and energy imparted. Doses to individual organs are estimated using normalized organ dose data and a knowledge of tube potential and field size.

Equipment Design↗

An instrument for monitoring the force applied by breast compression devices on mammography x-ray sets.

Automatic breast compression devices are commonly fitted to mammographic x-ray sets. The force exerted by these compression devices should be limited and periodically checked. This article describes the design and construction of an instrument for the routine assessment of the force applied by breast compression devices on mammography x-ray sets. Results obtained on four different mammography x-ray units are presented. In addition, data on the effect of compression plate design on compression force is given for one unit. The instrument has proved to be a simple and quick method of monitoring the force applied by the compression plates on mammographic x-ray units.