Transthoracic defibrillation using sequential and simultaneous dual shock pathways: experimental studies.

Dual pathway sequential DC shocks reduce energy requirements for internal defibrillation. Our purpose was to determine if dual pathway shocks similarly reduce energy requirements or improve shock success in transthoracic (external) defibrillation. We studied 39 closed-chest anesthetized mongrel dogs. The dual pathways used were left chest to right chest and left chest to posterior. In eight dogs we also assessed dual shock pathways oriented orthogonally, left lower chest to right upper chest and left upper chest to right lower chest. Four different dual pathway groups were studied: group 1: simultaneous shocks, sinusoidal waveform; group 2: sequential shocks, sinusoidal waveform, 100-msec shock separation, orthogonal shock pathways; group 3: sequential shocks, sinusoidal waveform, 100 msec shock separation; and group 4: sequential shocks, rectangular waveform (sequential shocks: 2 pulses, 2.5 msec each, 0.1-msec separation; single shock: 1 pulse, 5 msec). Shocks were given at 50 (J) joules, 100 J and 150 J and curves of energy versus success compared for dual pathway shocks versus single shocks. We found that the highest mean success rates (96 +/- SD 9%) were achieved by simultaneous sinusoidal waveform dual pathway shocks at 100 J; this was identical to results achieved by the single pathway sinusoidal waveform comparison shocks at 100 J. Sequential dual pathway sinusoidal shocks separated by 100 msec achieved a mean success rate of 79 +/- 31% at 150 J; the comparison single pathway mean success rate was similar: 81 +/- 22% at 150 J. Thus, dual pathway sequential or simultaneous transthoracic shocks did not demonstrate clear superiority over single pathway shocks.

Animals

High frequency epicardial echocardiography for coronary artery evaluation: in vitro and in vivo validation of arterial lumen and wall thickness measurements.

The purpose of this study was to determine the accuracy of a new high frequency echocardiographic technique for the quantitative assessment of coronary artery luminal and wall dimensions. In 32 open chest animals, high frequency echocardiographic measurements (echo) of luminal diameter correlated well with in vitro histologic measurements (Histo) (r = 0.86; high frequency echo = 0.89 Histo + 0.79) (range 1.7 to 5.8 mm). Similar results were found in the evaluation of five human autopsy hearts studied in vitro. Coronary artery wall thickness measurements in human autopsy hearts showed a good correlation with high frequency echocardiographic measurements (r = 0.86; high frequency echo = 0.65 Histo + 0.24) (range 0.3 to 0.8 mm). In eight open chest calves, high frequency echocardiographic measurements of total vessel diameter correlated well with sonomicrometer measurements (Sono) (r = 0.94; high frequency echo = 1.03 Sono + 0.4) (range 2.1 to 5.3 mm). Inter- and intraobserver variability measurements of high frequency echocardiographic measurements demonstrated excellent reproducibility (r = 0.95, interobserver variability for wall thickness; r = 0.97, interobserver variability for luminal diameter; n = 10 postmortem human coronary arteries). In conclusion, high frequency echocardiography is an accurate and reproducible method of measuring coronary luminal and wall geometry and may be a potentially useful tool for in vivo coronary artery evaluation in patients.

Animals

Defibrillator electrode-chest wall coupling agents: influence on transthoracic impedance and shock success.

The purpose of this study was to determine if the difference in transthoracic impedance produced by different coupling agents affects the success of shocks for defibrillation. Three different coupling agents, Harco pads (Hewlett-Packard), Littman pads (3M) and Redux paste (Hewlett-Packard), were assessed in 10 anesthetized dogs in which ventricular fibrillation was induced by electrical stimulation of the right ventricle. Defibrillation was attempted 15 seconds later, using 50, 100 and 150 joules (selected energy). Actual delivered energy, current, impedance and the percent of the shocks that achieved defibrillation were determined for the three coupling agents. Redux paste gave significantly lower impedance and higher current than the two disposable performed coupling pads tested. Despite this, there were no significant differences in shock success among the three coupling agents. Thus, in this experimental model, over a three-fold energy range, disposable coupling pads were as effective as electrode paste for defibrillation despite the slightly higher impedance of the disposable pads.

Alcohols

Automated impedance-based energy adjustment for defibrillation: experimental studies.

In defibrillation, current flow depends on the energy selected and the transthoracic impedance. If transthoracic impedance is high, current flow may be inadequate to defibrillate. We developed a method by which high transthoracic impedance is automatically compensated for by an increase in operator-selected energy when impedance is high. Transthoracic impedance was predicted in advance of the first shock by passing a low-level current between the defibrillator electrodes during the defibrillator charge cycle; a microprocessor monitored current flow and determined impedance. In 28 mongrel dogs we manipulated transthoracic impedance by placing glycerin-soaked gauze pads between the paddle electrodes and the chest. If the predicted impedance exceeded a preset value, the delivered energy was automatically increased by 40% or 100%. Using this impedance-based energy adjustment technique, we found significant improvements in current flow and success rate of shocks when energy was automatically increased to compensate for high transthoracic impedance. The use of transthoracic impedance as a basis for energy adjustment appears a promising technique to minimize the hazards of high electrical energy; it allows low-energy shocks in most patients while avoiding inappropriate low energies in patients with high impedance. Clinical trials are justified.

Animals

Echocardiographically detected dyskinesis, myocardial infarct size, and coronary risk region relationships in reperfused canine myocardium.

After permanent coronary artery occlusion, the extent of two-dimensional echocardiographically detected dyskinesis correlates well with infarct size. Reperfusion after coronary artery occlusion decreases infarct size; however, contractile function of myocardium salvaged in this way may remain depressed for several weeks. The purpose of this study was to explore the relationship between echocardiographically detected dyskinesis and infarct size in reperfused myocardium. We hypothesized that after transient coronary artery occlusion, the relationship between dyskinesis and infarct size would be altered because of the prolonged depression of contractile function after reperfusion so that dyskinesis would not predict infarct size. We also wanted to explore two related questions: (1) Does inotropic stimulation of reperfused myocardium result in improved systolic function in segments that are dysfunctional but not necrotic? (2) Does the relationship between infarct size and coronary risk region, which is linear in myocardium subjected to permanent coronary occlusion, remain linear in myocardium subjected to a sequence of occlusion and reperfusion? Thirty-seven sedated dogs with preplaced circumflex occluders underwent 1 or 2 hr of coronary artery occlusion, then 2 or 10 days of reperfusion. The percentage of the left ventricle that was dyskinetic was estimated from short-axis two-dimensional echocardiograms at the chordal and papillary muscle level obtained at control, after 1 or 2 hr of occlusion, after 20 min of reperfusion, and after 2 or 10 days of reperfusion. At 2 or 10 days of reperfusion, echocardiograms were also obtained during infusion of dobutamine. Area at risk was determined from postmortem barium-gelatin angiography and infarct size was determined at pathologic examination. We found a significant linear correlation between infarct size and risk region size in reperfused myocardium.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals