PubMed Health⌕ Search

Biomedical subjects

P Hopgood

Publications and source records attributed to P Hopgood.

10 recordsLinked to original sources

Delayed repair of the quadriceps using the Mitek anchor system: a case report and review of the literature.

Extensor mechanism disruptions are relatively uncommon knee injuries. Within this group, delayed treatment is an infrequent but difficult clinical situation. Fibrous degeneration, muscle contraction and subsequent hiatus present a challenge to the orthopaedic surgeon. We present an unusual case of a successful delayed repair using the Mitek anchors system (Mitek Products Inc., a division of Ethicon Inc., Westwood, Massachusetts).

Adult↗

Ankle arthrodesis for failed total ankle replacement.

Between 1999 and 2005, 23 failed total ankle replacements were converted to arthrodeses. Three surgical techniques were used: tibiotalar arthrodesis with screw fixation, tibiotalocalcaneal arthrodesis with screw fixation, and tibiotalocalcaneal arthrodesis with an intramedullary nail. As experience was gained, the benefits and problems became apparent. Successful bony union was seen in 17 of the 23 ankles. The complication rate was higher in ankles where the loosening had caused extensive destruction of the body of the talus, usually in rheumatoid arthritis. In this situation we recommend tibiotalocalcaneal arthrodesis with an intramedullary nail. This technique can also be used when there is severe arthritic change in the subtalar joint. Arthrodesis of the tibiotalar joint alone using compression screws was generally possible in osteoarthritis because the destruction of the body of the talus was less extensive. Tibiotalocalcaneal arthrodesis fusion with compression screws has not been successful in our experience.

Adult↗

A biomechanical comparison of the Mitek RapidLoc, Mitek Meniscal repair system, clearfix screws and vertical PDS and Ti-Cron sutures.

The aim of this in vitro study was to measure and compare the biomechanical properties and mode of failure of the five different methods of meniscal repair. Reproducible tears were created in 50 bovine medial menisci and repaired in a standardized fashion with one of the following devices: the RapidLoc meniscal repair device (Mitek Products, Westwood, MA), an 8 mm Mitek meniscal repair system (Mitek Products, Westwood, MA), Clearfix screw (Innovasive Devices, Marlborough, MA), a single vertical mattress suture of 2-0 Ti-Cron (Ethicon, Massachusetts) and a vertical mattress suture of No. 1 PDS II (Johnson and Johnson Int.). The repairs were tested by single cycle load to failure in a materials testing machine. The mean loads to failure for each of the repair groups were as follows: Mitek RapidLoc 44.9 N, Mitek meniscal repair system 20.3 N, Clearfix screw 37.4 N, vertical Ti-Cron 66.1 N and vertical PDS suture 103.0 N. The mean load to failure was significantly greater with PDS vertical sutures than with other techniques (P<0.05). The Mitek RapidLoc had the least extension at failure (14.8 mm) (P<0.05). This study confirms meniscal repair with vertical PDS sutures confers the highest biomechanical stability and that the new Mitek RapidLoc device offers improved load to failure than the previous generations.

Absorbable Implants↗

The role of MRSA screening in joint-replacement surgery.

The aim of this prospective study was to determine the effect of screening for methicillin-resistant Staphylococcus aureus (MRSA), in patients undergoing total hip and knee replacements, on reducing hospital-acquired infections and the length of hospital stay. We included 395 patients admitted to the elective orthopaedic ward for hip and knee replacements (knee 210; hip 185) from 16 October 2000 to 15 October 2001. Group 1 included 164 admissions before 16 April 2001 when MRSA swabs were not compulsory. Group 2 included 231 admissions after 16 April 2001 when axillary, nasal and groin swabs had to be negative for MRSA. Four patients in group 1 had post-operative MRSA infection compared with none in group 2. The mean length of hospital stay decreased significantly from 10.43 days +/- SD 4.2 days in group 1 to 9.47 days +/- SD 2.6 days in group 2. There was a significant reduction in the incidence of hospital-acquired infections following the introduction of pre-admission screening.

Aged↗

Subungual exostosis following toe nail removal--case report.

Removal of toe nail is a minor procedure that can be under ring block with no significant complications. We report the case of a young lady who developed a rapidly growing subungual exostosis on her right great toe following nail removal. Inadvertent iatrogenic injury to the nail bed and underlying phalangeal periosteum during nail removal might have triggered off rapid bone growth resulting in the large exostosis. To our knowledge, this aetiology for subungual exostosis formation has not been reported before.

Adult↗

The effect of tibial implant size on post-operative alignment following medial unicompartmental knee replacement.

We have retrospectively reviewed a consecutive series of 71 medial unicompartmental knee replacements in 56 patients performed between 1991 and 1996 by a single surgeon. The aim of this study was to quantify the amount of correction in the tibiofemoral angle, which is achievable with each thickness of polyethylene tibial insert. Our results have shown that the amount of correction which can be expected with an 8 mm, 10 mm, 12 mm and 14 mm insert are 5.3 degrees, 4.8 degrees, 6.6 degrees and 9.5 degrees, respectively. These results will act as a useful reference for surgeons who perform this procedure.

Aged↗

Migration of a broken meniscal arrow: a case report and review of the literature.

Meniscal repair is a common procedure that can be performed by the inside-out, outside-in, and all-inside techniques. The all-inside technique using the meniscal arrow is increasingly popular. We report a case in which a broken segment of a meniscal arrow was found on exploration of a subcutaneous swelling around the knee three weeks following meniscal repair.

Absorbable Implants↗