PubMed Health⌕ Search

Biomedical subjects

P Husar

Publications and source records attributed to P Husar.

8 recordsLinked to original sources

Spectral characteristics of light sources for S-cone stimulation.

PURPOSE: Electrophysiological investigations of the short-wavelength sensitive pathway of the human eye require the use of a suitable light source as a S-cone stimulator. Different light sources with their spectral distribution properties were investigated and compared with the ideal S-cone stimulator. METHODS: First, the theoretical background of the calculation of relative cone energy absorption from the spectral distribution function of the light source is summarized. From the results of the calculation, the photometric properties of the ideal S-cone stimulator will be derived. The calculation procedure was applied to virtual light sources (computer generated spectral distribution functions with different medium wavelengths and spectrum widths) and to real light sources (blue and green light emitting diodes, blue phosphor of CRT-monitor, multimedia projector, LCD monitor and notebook display). The calculated relative cone absorbencies are compared to the conditions of an ideal S-cone stimulator. RESULTS: Monochromatic light sources with wavelengths of less than 456 nm are close to the conditions of an ideal S-cone stimulator. Spectrum widths up to 21 nm do not affect the S-cone activation significantly (S-cone activation change < 0.2%). Blue light emitting diodes with peak wavelength at 448 nm and spectrum bandwidth of 25 nm are very useful for S-cone stimulation (S-cone activation approximately 95%). A suitable display for S-cone stimulation is the Trinitron computer monitor (S-cone activation approximately 87%). The multimedia projector has a S-cone activation up to 91%, but their spectral distribution properties depends on the selected intensity. LCD monitor and notebook displays have a lower S-cone activation (< or = 74%). CONCLUSION: Carefully selecting the blue light source for S-cone stimulation can reduce the unwanted L-and M-cone activation down to 4% for M-cones and 1.5% for L-cones.

Humans↗

[Improving SNR (signal to noise ratio) in multichannel EEG recording].

The main problem in measurements of the focal VEP (Visual Evoked Potential) is its weak SNR (Signal-to-Noise Ratio). The most common method for enhancement of the SNR is the stimulus synchronized averaging. For study of single responses other ways in SNR improvement are needed. In this contribution a new method based on space-time selective measurement is introduced, which can be interpreted as beaming a signal source. Since the anatomical structures of sources generating the focal VEP are known in general and if the electrode positions are of sufficient density over the visual cortex, a source beamer can be realized by controlling the channels' delays.

Algorithms↗

A periodogram-based method for the detection of steady-state visually evoked potentials.

The task of objective perimetry is to scan the visual field and find an answer about the function of the visual system. Flicker-burst stimulation--a physiological sensible combination of transient and steady-state stimulation--is used to generate deterministic sinusoidal responses or visually evoked potentials (VEP's) at the visual cortex, which are derived from the electroencephalogram by a suitable electrode array. In this paper we develop a new method for the detection of VEP's. Based on the periodogram of a time-series, we test the data for the presence of hidden periodic components, which correspond to steady-state VEP's. The method is applied successfully to real data.

Electroencephalography↗