Volumetric spectroscopic imaging with spiral-based k-space trajectories.

Spiral-based k-space trajectories were applied in a spectroscopic imaging sequence with time-varying readout gradients to collect volumetric chemical shift information. In addition to spectroscopic imaging of low signal-to-noise ratio (SNR) brain metabolites, the spiral trajectories were used to rapidly collect reference signals from the high SNR water signal to automatically phase the spectra and to aid the reconstruction of metabolite maps. Spectral-spatial pulses were used for excitation and water suppression. The pulses were designed to achieve stable phase profiles in the presence of up to 20% variation in the radiofrequency field. A gridding algorithm was used to resample the data onto a rectilinear grid before fast Fourier transforms. This method was demonstrated by in vivo imaging of brain metabolites at 1.5 T with 10 slices of 18 x 18 pixels each. Nominal voxel size was 1.1 cc, spectral bandwidth was 400 Hz, scan time was 18 min for the metabolite scan and 3 min for the reference scan.

Aspartic Acid↗

Inhomogeneity correction using an estimated linear field map.

A fast and robust method for correcting magnetic resonance image distortion due to field inhomogeneity is proposed and applied to spiral k-space scanning. The method consists of acquiring a local field map, finding the best fit to a linear map, and using it to deblur the image distortions due to local frequency variations. The linear field map is determined using a maximum likelihood estimator with weights proportional to the pixel intensity. The method requires little additional computation and is robust in low signal regions and near abrupt field changes. Additionally, it can be used in combination with other deblurring methods. The application of this method is illustrated in conjunction with a multislice, T2-weighted, breath-held spiral scan of the liver.

Abdomen↗

Three-dimensional spectroscopic imaging with time-varying gradients.

A spectroscopic imaging sequence with a time-varying readout gradient in the slice selection direction is used to image multiple contiguous slices. For a given voxel size, the imaging time and signal-to-noise ratio of the three-dimensional spectroscopic sequence are the same as for a single slice acquisition without the oscillating readout gradient. The data reconstruction employs a gridding algorithm in two dimensions to interpolate the nonuniformly sampled data onto a Cartesian grid, and a fast Fourier transform in four dimensions: three spatial dimensions and the spectral dimension. The method is demonstrated by in vivo imaging of NAA in human brain at 1.5 T with 10 slices of 16 x 16 pixels spectroscopic images acquired in a total scan time of 17 min.

Algorithms↗

A velocity k-space analysis of flow effects in echo-planar and spiral imaging.

A velocity k-space formalism facilitates the analysis of flow effects for imaging sequences involving time-varying gradients such as echo-planar and spiral. For each sequence, the velocity k-space trajectory can be represented by kv(kr); that is, its velocity-frequency (kv) position as a function of spatial-frequency (kr) position. In an echo-planar sequence, kv is discontinuous and asymmetric. However, in a spiral sequence, kv is smoothly varying, circularly symmetric, and small near the kr origin. To compare the effects of these trajectory differences, simulated images were generated by computing the k-space values for an in-plane vessel with parabolic flow. Whereas the resulting echo-planar images demonstrate distortions and ghosting that depend on the vessel orientation, the spiral images exhibit minimal artifacts.

Artifacts↗

Fast three dimensional magnetic resonance imaging.

To reduce the scan time in three-dimensional (3D) imaging, the authors consider alternative trajectories for traversing k-space. They differ from traditional 3D trajectories, such as 3DFT, in that they employ time-varying gradients allowing longer readouts and in turn a reduced scan time. Some of these trajectories reduce by an order of magnitude the number of excitations compared with 3DFT and provide flexibility for trading off signal-to-noise ratio for scan time. Other concerns are the minimum echo time and flow/motion properties. As examples, the authors show two applications: A 3D data set of the head (field of view of 30 x 30 x 7.5 cm and resolution of 1.5 x 1.5 x 1.5 mm) acquired in 56 s using a stack of spirals in 3D k-space; and a 3D movie of the heart (20 x 20 x 20 cm field of view, 2 x 2 x 2 mm resolution, and 16 time frames per cardiac cycle) acquired in 11 min using a cones trajectory.

Fourier Analysis↗

The diminishing variance algorithm for real-time reduction of motion artifacts in MRI.

A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of several algorithms to reduce or eliminate motion effects from an image as it is being acquired. One such algorithm previously described is the acceptance/rejection method. This paper deals with another real-time algorithm called the diminishing variance algorithm (DVA). With this method, a complete set of preliminary data is acquired along with information about the relative motion position of each frame of data. After all the preliminary data are acquired, the position information is used to determine which data frames are most corrupted by motion. Frames of data are then reacquired, starting with the most corrupted one. The position information is continually updated in an iterative process; therefore, each subsequent reacquisition is always done on the worst frame of data. The algorithm has been implemented on several different types of sequences. Preliminary in vivo studies indicate that motion artifacts are dramatically reduced.

Algorithms↗

Spatially resolved and localized real-time velocity distribution.

A technique is presented for collecting the spin velocity distribution as a function of position and time. It uses a multidimensional excitation pulse to select a cylinder, giving localization in two dimensions. Resolution in the third spatial dimension is achieved in the readout. During readout, an oscillating gradient encodes the acquired data in both one spatial dimension (x) and one velocity dimension (v). Two acquisitions (42 ms each) are needed to get a complete coverage of kx--kv space, which makes this technique real-time. The data is interpolated from the nonuniformly sampled kx--kv space to a Cartesian frame with a gridding scheme to take advantage of the Fast Fourier Transform. The technique was successfully applied to phantoms and normal volunteers, giving reasonable real-time measurements of velocity.

Blood Flow Velocity↗