PubMed Health⌕ Search

Biomedical subjects

P Irarrazaval

Publications and source records attributed to P Irarrazaval.

4 recordsLinked to original sources

Matrix description of general motion correction applied to multishot images.

Motion of an object degrades MR images, as the acquisition is time-dependent, and thus k-space is inconsistently sampled. This causes ghosts. Current motion correction methods make restrictive assumptions on the type of motions, for example, that it is a translation or rotation, and use special properties of k-space for these transformations. Such methods, however, cannot be generalized easily to nonrigid types of motions, and even rotations in multiple shots can be a problem. Here, a method is presented that can handle general nonrigid motion models. A general matrix equation gives the corrupted image from the ideal object. Thus, inversion of this system allows us to get the ideal image from the corrupted one. This inversion is possible by efficient methods mixing Fourier transforms with the conjugate gradient method. A faster but empirical inversion is discussed as well as methods to determine the motion. Simulated three-dimensional affine data and two-dimensional pulsation data and in vivo nonrigid data are used for demonstration. All examples are multishot images where the object moves between shots. The results indicate that it is now possible to correct for nonrigid types of motion that are representative of many types of patient motion, although computation times remain an issue.

Algorithms↗

Fast magnetic resonance coronary angiography with a three-dimensional stack of spirals trajectory.

In this work, three-dimensional (3D) spiral imaging has been utilized for magnetic resonance coronary angiography. Spiral-based 3D techniques can dramatically reduce imaging time requirements compared with 3D Fourier Transform imaging. The method developed here utilized a "stack of spirals" trajectory, to traverse 3D k-space rapidly. Both thick-slab volumes encompassing the entire coronary tree with isotropic resolution and thin-slab volumes targeted to a particular vessel of interest were acquired. Respiratory compensation was achieved using the diminishing variance algorithm. T2-prepared contrast was also applied in some cases to improve contrast between vessel and myocardium, while off-resonance blurring was minimized by applying a linear correction to the acquired data. Images from healthy volunteers were displayed using a curved reformatting technique to view long segments of vessel in a single projection. The results demonstrate that this 3D spiral technique is capable of producing high-quality coronary magnetic resonance angiograms.

Algorithms↗

3D MR coronary artery segmentation.

Coronary arteries are segmented from the blood pool using mathematical morphology operations from a 3D magnetic resonance spiral acquisition on a continuously breathing healthy volunteer. The segmented volume is maximal intensity projected at different views to yield coronary angiograms showing the left anterior descending artery (LAD), right coronary artery (RCA), and left circumflex artery (LCX). Magnetic resonance coronary angiography provides a retrospective rotating view of the coronary artery tree that complements oblique reformatted sections.

Algorithms↗

Three-dimensional flow-independent peripheral angiography.

A magnetization-prepared sequence, T2-Prep-IR, exploits T1, T2, and chemical shift differences to suppress background tissues relative to arterial blood. The resulting flow-independent angiograms depict vessels with any orientation and flow velocity. No extrinsic contrast agent is required. Muscle is the dominant source of background signal in normal volunteers. However, long-T2 deep venous blood and nonvascular fluids such as edema also contribute background signal in some patients. Three sets of imaging parameters are described to address patient-specific contrast requirements. A rapid, spiral-based, three-dimensional readout is utilized to generate high-resolution angiograms of the lower extremities. Comparisons with x-ray angiography and two-dimensional time-of-flight angiography indicate that this flow-independent technique has unique capabilities to accurately depict stenoses and to visualize slow flow and in-plane vessels.

Angiography↗