Coronary artery compliance and adaptive vessel remodelling in patients with stable and unstable coronary artery disease.

OBJECTIVE: To test the hypothesis that patients with unstable coronary syndromes show accentuated compensatory vessel enlargement compared with patients with stable angina, and that this may in part be related to increased coronary artery distensibility. DESIGN AND PATIENTS: In 23 patients with unstable coronary syndromes (10 with non-Q wave myocardial infarction and 13 with unstable angina), the culprit lesion was investigated by intravascular ultrasound before intervention. The vessel cross sectional area (VA), lumen area (LA), and plaque area (VA minus LA) were measured at end diastole and end systole at the lesion site and at the proximal and distal reference segments. Similar measurements were made in 23 patients with stable angina admitted during the same period and matched for age, sex, and target vessel. Calculations were made of remodelling index (VA at lesion site / VA at reference site), distensibility index ([(delta A/A)/delta P] x 10(3), where delta A is the luminal area change in systole and diastole and delta P the difference in systolic and diastolic blood pressure measured at the tip of the guiding catheter during a cardiac cycle), and stiffness index beta ([ln(P(sys)/P(dias))]/(delta D/D), where P(sys) is systolic pressure, P(dias) is diastolic pressure, and delta D is the difference between systolic and diastolic lumen diameters). Positive remodelling was defined as when the VA at the lesion was > 1.05 times larger than at the proximal reference site, and negative remodelling when the VA at the lesion was < 0.95 of the reference site. RESULTS: Mean (SD) LA at the lesion site was similar in both groups (4.03 (1.8) v 4.01 (1. 93) mm(2)), while plaque area was larger in the unstable group (13. 29 (4.04) v 8.34 (3.6) mm(2), p < 0.001). Remodelling index was greater in the unstable group (1.14 (0.18) v 0.83 (0.15), p < 0.001). Positive remodelling was observed in 15 patients in the unstable group (65%) but in only two (9%) in the stable group (p < 0.001). Negative remodelling occurred only in two patients with unstable symptoms (9%) but in 17 (74%) with stable symptoms. At the proximal reference segment, the difference in LA between systole and diastole was 0.99 (0.66) mm(2) in the unstable group and 0.39 (0.3) mm(2) in the stable group (p < 0.001), and the calculated coronary artery distensibility was 3.09 (2.69) and 0.94 (0.83) per mm Hg in unstable and stable patients, respectively (p < 0.001). The stiffness index beta was lower in patients with unstable angina (1.95 (0.94) v 3.1 (0.96), p < 0.001). CONCLUSIONS: Compensatory vessel enlargement occurs to a greater degree in patients with unstable than with stable coronary syndromes, and is associated with increased coronary artery distensibility.

Aged↗

Feasibility of in vivo intravascular ultrasound tissue characterization in the detection of early vascular transplant rejection.

BACKGROUND: Unprocessed ultrasound radiofrequency (RF) signal analysis has been shown to distinguish different tissue structures more reliably than gray-scale interpretation of conventional ultrasound images. METHODS AND RESULTS: The objective of this study was to test the feasibility of in vivo intravascular ultrasound (IVUS) RF signal analysis in an animal model of allograft rejection. Six cynomolgus monkeys underwent transplantation of 3-cm aortic allograft segments distal to the renal arteries from immunologically mismatched donors. IVUS imaging with a 30-MHz system was performed 84 to 105 days after the operation. RF signals were acquired from cross sections of the recipient and the allograft aortas in real time with a digitizer at 500 MHz with 8-bit resolution. Sixty-five cross sections and 68 regions of interest (31 in host aorta and 37 in allograft) were analyzed in the adventitial layer with a total number of 8568 vectors processed. For each region of interest, a weighted-average attenuation was calculated on the basis of the attenuation and length for each individual vector. Histological examination was performed at every cross section imaged by IVUS. When the gray-scale images of conventional IVUS scored by an independent observer were compared, no distinction between adventitia of the native aorta and allograft was possible. Analysis of the average RF backscatter power also showed no significant difference (70.32+/-3.55 versus 70.72+/-3.38 dB). However, the average attenuation of allografts was significantly lower than that of the host aortas (2.64+/-1.38 versus 4.02+/-1.16 dB/mm, P<0.001). Histology demonstrated a marked adventitial inflammatory response in all allografts, with no inflammation observed in the host aortas. CONCLUSIONS: In vivo IVUS tissue characterization can be performed during routine imaging. In this model of transplant vasculopathy, RF attenuation measurements were more sensitive than visual or quantitative gray-scale analysis.

Animals↗

Intravascular ultrasound volumetric assessment of intimal hyperplasia in stents treated with intracoronary radiation.

Iridium-192 (gamma)-radiation is effective in preventing recurrent in-stent restenosis by reducing neointimal hyperplasia as illustrated by intravascular ultrasound study and plaque area-length plot. This analytic technique will further our understanding of vessel behavior to radiant energy source both inside and outside the stented coronary artery segments.

Constriction, Pathologic↗

Impact of residual plaque burden on clinical outcomes of coronary interventions.

In this study, we summarize the role of residual plaque burden, as determined by intravascular ultrasound, on the development of restenosis following percutaneus coronary interventions. Several clinical trials have shown that the amount of residual plaque is a consistent and independent predictor of subsequent restenosis. The impact of residual plaque burden on late lumen loss is particularly augmented by negative vessel remodeling that is commonly seen after balloon angioplasty and atherectomy. However, early evidence suggests that the importance of plaque burden also applies in the context of stenting. The cotreatment of debulking may further improve the long-term outcome of stenting by maximizing an acute lumen gain with less vessel stretching, preventing stent edge problems and possibly reducing the cell source involved in the intimal hyperplastic process. Evaluation of residual plaque burden with on-line intravascular ultrasound could lead to definitive therapies via risk stratification of the treated segments.

Angioplasty, Balloon, Coronary↗

Long-term clinical follow-up of patients treated with the coronary rotablator: a single-center experience.

The acute angiographic and long-term clinical outcomes of a consecutive series of patients treated with the coronary rotablator at a single center are described. The patient population was a high-risk population, with significant instances of unstable angina or acute myocardial infarctions (MI) on presentation (75.5%), three-vessel coronary artery disease (27.5%), congestive heart failure (23.8%), and diabetes (39%). The coronary anatomy was also complex, with 79.3% of lesions treated being National Heart Lung and Blood Institute (NHLBI) class B or C. The maximum burr:artery ratio averaged 0.79+/-0.11. The maximum balloon:artery ratio averaged 1.19+/-0.17. Acute procedural success was 90%. The reference vessel diameter was 2.72 mm +/-0.54 mm. The average minimum luminal diameter (MLD) preprocedure was 0.87+/-0.31 mm. The average MLD postprocedure was 2.01+/-0.54 mm. The acute gain averaged 1.14+/-0.51 mm. Urgent coronary artery bypass grafting was required in 1% of patients. Subendocardial infarctions occurred in 8.5% of patients, and abrupt closure postprocedure while in hospital occurred in 1% of patients. Reinterventions or coronary artery bypass grafting (CABG) in hospital occurred in only 3.5% of patients; 96% of patients were available for a long-term clinical follow-up. Repeat coronary interventions for target lesion revascularizations were required in 17.4% of patients, coronary artery bypass grafting for target lesion revascularization was necessary in 9.5% of patients, and the combined target lesion revascularization rate was 25.3% at 1 year. Subsequent Q-wave myocardial infarctions or cardiac death occurred in 5.7% of patients at 1 year. Event-free survival was 75.1% at 6 months and 69.9% at 1 year. The strongest predictor of subsequent target lesion revascularization was lesion length (P=0.034) and not the postprocedure MLD (P=0.41). Most major adverse clinical events occurred within the first 4 months and greater than 90% of all major adverse clinical events occurred within the first 6 months. The coronary rotablator was able to achieve a high degree of clinical success in a high-risk patient population with complex anatomy. Most major adverse clinical events occurred early (<6 months) and were comprised principally of target lesion revascularizations. The overall target lesion revascularization rates and combined major adverse clinical event rates are favorable, given the complex anatomy and the high proportion of diabetics, females, and multivessel disease patients treated in this series.

Coronary Angiography↗

The progression of thrombus in an ex-vivo shunt model evaluated by intravascular ultrasound radiofrequency analysis.

We tested the ability of ultrasound radiofrequency (RF) signal analysis to characterize thrombus accumulation in a Dacron graft incorporated into the exteriorized arteriovenous shunt in 3 baboons with constant blood flow for 60 min. Thrombus formation was quantified by sequential measurements of 111Indium-labeled platelet deposition. RF signals were acquired every 15 min at 2 sites in the graft, using a 2.9 Fr intravascular ultrasound catheter-based transducer (30 MHz) and digitized at 250 MHz in 8-bit resolution. Regions of interest were placed within a 0.5-mm perimeter adjacent to the graft wall. Integrated backscatter increased significantly (p < 0.001) with increasing platelet deposition. However, mean-to-standard deviation ratio of the RF envelope showed no significant change and the distribution pattern of the RF probability function remained constant and consistent with a Rayleigh scattering process. These results provide a basis for using RF analysis to monitor the time-course of thrombus formation.

Analysis of Variance↗

Effects of adjunctive balloon angioplasty after intravascular ultrasound-guided optimal directional coronary atherectomy: the result of Adjunctive Balloon Angioplasty After Coronary Atherectomy Study (ABACAS).

OBJECTIVES: This study was conducted to evaluate: 1) the effect of adjunctive percutaneous transluminal coronary angioplasty (PTCA) after directional coronary atherectomy (DCA) compared with stand-alone DCA, and 2) the outcome of intravascular ultrasound (IVUS)-guided aggressive DCA. BACKGROUND: It has been shown that optimal angiographic results after coronary interventions are associated with a lower incidence ofrestenosis. Adjunctive PTCA after DCA improves the acute angiographic outcome; however, long-term benefits of adjunctive PTCA have not been established. METHODS: Out of 225 patients who underwent IVUS-guided DCA, angiographically optimal debulking was achieved in 214 patients, then theywere randomized to either no further treatment or to added PTCA. RESULTS: Postprocedural quantitative angiographic analysis demonstrated an improved minimum luminal diameter (2.88 +/- 0.48 vs. 2.6 +/- 0.51 mm; p = 0.006) and a less residual stenosis (10.8% vs.15%; p = 0.009) in the adjunctive PTCA group. Quantitative ultrasound analysis showed a larger minimum luminal diameter (3.26 +/- 0.48 vs. 3.04 +/- 0.5 mm; p < 0.001) and lower residual plaque mass in the adjunctive PTCA group (42.6% vs. 45.6%; p < 0.001). Despite the improved acute findings in the adjunctive PTCA group, six-month angiographic and clinical results were not different. The restenosis rate (adjunctive PTCA 23.6%, DCA alone 19.6%; p = ns) and target lesion revascularization rate (20.6% vs. 15.2%; p = ns) did not differ between the groups. CONCLUSIONS: With IVUS guidance, aggressive DCA can safely achieve optimal angiographic results with low residual plaque mass, and this was associated with a low restenosis rate. Although adjunctive PTCA after optimal DCA improved the acute quantitative coronary angiography and quantitative coronary ultrasonography outcomes, its benefit was not maintained at six months.

Aged↗

Coronary stents: In vitro aspects of an angiographic and ultrasound quantification with in vivo correlation.

BACKGROUND: The validity of quantitative coronary angiography (QCA) after stent placement has been questioned because the optical density of a metallic stent, added to the density of a contrast-filled lumen, could affect border definition. METHODS AND RESULTS: We deployed 3.0- and 4.0-mm Palmaz-Schatz, Wiktor, Multilink, NIR, and InStent stents in precision-cast phantoms. Central lumens of 2.0 mm were created. There was no difference between the "true" diameters of any stented lumen by both QCA and quantitative ultrasonic (QCU) measurement poststenting. QCA systematic error (SE) varied from 0.01 for the Wiktor stents to 0.14 mm for the Palmaz-Schatz stents; the random error (RE) was 0.03 to 0.14 mm. QCU SE varied from 0.05 to 0.11 mm, and RE ranged from 0.01 to 0.07 mm. At the next stage, 4.0-mm Wiktor and Palmaz-Schatz stents were deployed into the phantom lumens; 1.5-, 2.0-, 2.5- and 3.0-mm lumens were created inside the stents. QCA and QCU measurements of 1.5- to 2.5-mm residual lumens were overestimated by 0.1 to 0.3 mm. In the 3. 0-mm residual lumen within the Wiktor stent, QCA underestimated the luminal size by -0.1 mm. There was no QCA inaccuracy for a 3.0-mm lumen within the Palmaz-Schatz stent. In patients, in 25 stented segments in both the Palmaz-Schatz and Wiktor groups, there was no difference between QCA and QCU diameters. CONCLUSIONS: QCU is sufficiently precise for the assessment of the coronary lumen after stenting. QCA can be used as an accurate method of poststent assessment, except when a very mild recurrence within a highly opaque stent is measured. In that instance, QCA may underestimate the luminal diameter.

Coronary Angiography↗

Intravascular ultrasound: state of the art and future directions.

A variety of new devices in the field of intravascular ultrasound imaging are being designed and tested. Mechanical intravascular ultrasound (IVUS) devices with rotating transducers have been developed that allow transducer pullback with integrated longitudinal 2-dimensional displays. Recent advances in the area of imaging include (1) solid-state systems that combine ultrasound with balloon and stent placement; (2) combined imaging atherectomy devices; (3) imaging cores or guidewires; (4) forward-looking devices; (5) 3-dimensional reconstruction techniques; (6) high-frequency imaging; and (7) improved methods for characterizing tissue. Other promising approaches include magnetic resonance imaging, thermography, and optical coherence tomography. An important goal for long-term technologic improvement is visualization of lipid accumulations and fibrous caps during their early stages of development.

Animals↗

'Optimal' directional coronary atherectomy: final results of the Optimal Atherectomy Restenosis Study (OARS).

BACKGROUND: Previous clinical trials of directional coronary atherectomy (DCA) have failed to show significant improvement in early or late outcomes compared with balloon angioplasty (PTCA). The present study tested the hypothesis that more aggressive "optimal" atherectomy could be performed safely to produce larger initial lumen diameters and a lower late restenosis rate. METHODS AND RESULTS: The present study was a prospective multicenter registry of consecutive patients undergoing optimal DCA of de novo or restenotic lesions in 3.0- to 4.5-mm native coronary arteries. Optimal DCA was defined as using a 7F atherectomy device and adjunctive PTCA if necessary to achieve a < 15% residual stenosis. Six-month angiographic and 1-year clinical follow-up was planned in all patients. A total of 199 patients with 213 lesions met eligibility criteria for enrollment. Short-term procedural success was achieved in 97.5%, with a major complication rate (death, emergency bypass surgery, or Q-wave myocardial infarction [MI]) of 2.5%. There were no early deaths. Non-Q-wave MI (CK-MB > 3 times normal) occurred in 14% of patients. Mean reference vessel diameter was 3.28 mm. Mean diameter stenosis was reduced from 63.5% to a final stenosis of 7%. Late 1-year clinical follow-up revealed one cardiac death and a target lesion revascularization rate of 17.8%. The angiographic restenosis rate at 6 months was 28.9%, with the major predictor of restenosis being a smaller postprocedure lumen diameter. CONCLUSIONS: Optimal DCA produced a low residual percent diameter stenosis and a lower restenosis rate than seen in previous trials without an increase in early or late major adverse events.

Aged↗

The stent decade: 1987 to 1997. Stanford Stent Summit faculty.

In January 1997, experts from the United States, Europe, and Japan gathered at Stanford University to review their collective experience with intracoronary and noncoronary stenting and to identify and prioritize issues requiring further clinical investigation. This report summarizes the discussions that took place during this stent summit. Knowledge of stent-tissue interaction from animal and human pathologic specimens was reviewed in the context of evolving stent designs. The relative merits of coil and slotted tubular stent designs were discussed. Stent deployment routines, including self-expansion, balloon expansion, and high-pressure delivery were debated. The potential for covered stents and coated stents was explored. Problems surrounding the routine deployment of stents were identified: small vessel disease, long lesions, bifurcation stenoses, vein graft disease, ostial disease, left main stenoses, and intrastent restenosis. The value of intravascular ultrasound, as an adjunct to stenting, was explored and debated. An algorithm for "provisional stenting" based on ultrasound criteria was developed. Noncoronary stenting of the aorta, iliacs, and carotids were discussed. Clinical applications that may lead to randomized clinical trials were identified.

Carotid Arteries↗

Enhancement of spatial orientation of intravascular ultrasound images with side holes in guiding catheters.

BACKGROUND: Intravascular ultrasound (IVUS) images are typically viewed and recorded in an arbitrary rotational orientation. This study was performed to validate a new method for improved orientation of sonographic vascular cross-sections. METHODS AND RESULTS: We have tested a simple technique for rotational indexing of IVUS in cases in which guiding catheters with side holes are used. Although guiding catheters are opaque to ultrasonography, the side holes transmit the beam and therefore can be easily identified. The orientation of the side holes, which is characteristic for each make of guiding catheter, can be used to determine the anatomically appropriate rotational orientation of the IVUS image. In this study images of four commercially available side-hole guiding catheters were viewed in vitro to confirm the visibility of the side holes and to characterize their orientation for purposes of rotational orientation of images. Feasibility tests of rotational orientation based on side holes were then performed in canine coronary arteries (n = 3) and in six human coronary arteries. Three serial imaging runs in each clinical case yielded a mean variability in rotational orientation of 7.5 +/- 1.5 degrees. CONCLUSION: Validation testing of the side-hole technique demonstrates the potential for consistent and anatomically appropriate orientation of intravascular ultrasound images.

Animals↗

Remodeling after directional coronary atherectomy (with and without adjunct percutaneous transluminal coronary angioplasty): a serial angiographic and intravascular ultrasound analysis from the Optimal Atherectomy Restenosis Study.

OBJECTIVES: The intravascular ultrasound (IVUS) substudy of OARS (Optimal Atherectomy Restenosis Study) was designed to assess the mechanisms of restenosis after directional coronary atherectomy (DCA). BACKGROUND: Recent serial IVUS studies have indicated that late lumen loss after interventional procedures was determined primarily by the direction and magnitude of arterial remodeling, not by cellular proliferation. METHODS: Complete quantitative coronary angiography (QCA) and IVUS were obtained in 104 patients before and after intervention and during follow-up. All studies were performed after administration of 200 microg of intracoronary nitroglycerin. Angiographic measurements included minimum lumen diameter (MLD), interpolated reference diameter and diameter stenosis (DS). Intravascular ultrasound measurements included lesion and reference external elastic membrane (EEM), lumen and plaque+media cross-sectional area (CSA). The axial location of the lesion site was at the smallest follow-up lumen CSA; the reference segment was the most normal-looking cross section within 10 mm proximal to the lesion but distal to any major side branch. Results are reported as mean +/- one standard deviation. RESULTS: The QCA reference decreased from 3.51 +/- 0.46 mm to 3.22 +/- 0.44 mm; the MLD decreased from 3.22 +/- 0.47 mm to 2.03 +/- 0.72 mm; and the DS increased from 8 +/- 10% to 38 +/- 20%. On IVUS, the decrease in lumen CSA (from 8.8 +/- 2.5 mm2 to 5.5 +/- 4.0 mm2) was associated with a significant decrease in EEM (from 19.7 +/- 5.6 mm2 to 16.9 +/- 6.2 mm2); there was no significant increase in P+M (from 10.9 +/- 4.2 mm2 to 11.3 +/- 3.9 mm2). A change in lumen correlated with a change in EEM (r = 0.790, p < 0.0001), not with a change in P+M (r = 0.133, p = 0.2258). A decrease in reference EEM (from 19.1 +/- 7.7 mm2 to 17.6 +/- 8.0 mm2) also correlated with a decrease in lesion EEM (r = 0.665, p < 0.0001). Results in restenotic lesions were similar. CONCLUSION: Restenosis after optimal DCA is caused primarily by a decrease in EEM CSA that extends into contiguous reference segments.

Anatomy, Cross-Sectional↗

Orientation of intracoronary ultrasonography: looking beyond the artery.

Over the past 5 years intravascular ultrasound imaging has achieved many technical advancements both in catheter design and image quality. In addition to improved image quality that provides clear display of the endovascular structure, efficient signal penetration permits the viewing of structures beyond the artery by highlighting the perivascular structures. These perivascular landmarks, which are unique within a particular coronary segment, help provide both axial and spatial orientation during multiple imaging runs throughout a coronary artery. Orientation on the basis of veins and pericardium assists the operator to appreciate the full three-dimensional view of a particular coronary segment. This article describes several of the common perivascular structures that may be viewed from different arteries routinely imaged during coronary procedures.

Coronary Vessels↗

Characterisation of coronary atherosclerotic morphology by spectral analysis of radiofrequency signal: in vitro intravascular ultrasound study with histological and radiological validation.

OBJECTIVE: To determine whether spectral analysis of unprocessed radiofrequency (RF) signal offers advantages over standard videodensitometric analysis in identifying the morphology of coronary atherosclerotic plaques. METHODS: 97 regions of interest (ROI) were imaged at 30 MHz from postmortem, pressure perfused (80 mm Hg) coronary arteries in saline baths. RF data were digitised at 250 MHz. Two different sizes of ROI were identified from scan converted images, and relative amplitudes of different frequency components were analysed from raw data. Normalised spectra was used to calculate spectral slope (dB/MHz), y-axis intercept (dB), mean power (dB), and maximum power (dB) over a given bandwidth (17-42 MHz). RF images were constructed and compared with comparative histology derived from microscopy and radiological techniques in three dimensions. RESULTS: Mean power was similar from dense fibrotic tissue and heavy calcium, but spectral slope was steeper in heavy calcium (-0.45 (0.1)) than in dense fibrotic tissue (-0.31 (0.1)), and maximum power was higher for heavy calcium (-7.7 (2.0)) than for dense fibrotic tissue (-10.2 (3.9)). Maximum power was significantly higher in heavy calcium (-7.7 (2.0) dB) and dense fibrotic tissue (-10.2 (3.9) dB) than in microcalcification (-13.9 (3.8) dB). Y-axis intercept was higher in microcalcification (-5.8 (1.1) dB) than in moderately fibrotic tissue (-11.9 (2.0) dB). Moderate and dense fibrotic tissue were discriminated with mean power: moderate -20.2 (1.1) dB, dense -14.7 (3.7) dB; and y-axis intercept: moderate -11.9 (2.0) dB, dense -5.5 (5.4) dB. Different densities of fibrosis, loose, moderate, and dense, were discriminated with both y-axis intercept, spectral slope, and mean power. Lipid could be differentiated from other types of plaque tissue on the basis of spectral slope, lipid -0.17 (0.08). Also y-axis intercept from lipid (-17.6 (3.9)) differed significantly from moderately fibrotic tissue, dense fibrotic tissue, microcalcification, and heavy calcium. No significant differences in any of the measured parameters were seen between the results obtained from small and large ROIs. CONCLUSION: Frequency based spectral analysis of unprocessed ultrasound signal may lead to accurate identification of atherosclerotic plaque morphology.

Calcinosis↗