Intracoronary ultrasound imaging: intraobserver and interobserver variability of morphometric measurements.

Measurements of lumen and plaque dimensions by intracoronary ultrasound imaging are useful in assessing effects of intracoronary interventions and in quantifying plaque burden in transplant patients or during regression trials. However, these measurements are affected by inter- and intraobserver variability. In 87 patients, 120 intracoronary ultrasound images were obtained with a 4.3F, 30 MHz catheter. Morphometric measurements were performed two times by three independent observers using computerized planimetry. Intraobserver and interobserver agreement for qualitative parameters (presence of atherosclerotic plaque, calcified plaque, and residual nondiseased wall) was high (> 87%). For quantitative parameters measured directly in the images (lumen area, minimal and maximal lumen diameters, area within the internal elastic lamina, arc of calcium plaque) interobserver and intraobserver correlation between measurements was high (correlation coefficient r > 0.90) and differences between measurements were low (mean differences < 10%; SD < 20%). Measurement of the arc of nondiseased wall showed less interobserver correlation (r = 0.76 to 0.91), but percentages of difference between the measurements were low. Parameters derived from directly measured variables (plaque area, area stenosis, thickness, and eccentricity) showed slightly higher variability (correlations between measurements r = 0.78 to 0.91). SD for percentages of difference ranged between 20% and 30% (plaque area, area stenosis, and thickness) and systematic deviation between measurements (mean differences > 10%) occurred for plaque area. Thus most qualitative and quantitative measurements of lumen and plaque dimensions performed in intracoronary ultrasound images have low in intraobserver and interobserver variability; derived parameters may have slightly higher variability. Variability of morphometric measurements has to be considered, especially when serial ultrasound measurements are compared.

Adult↗

Detection of intralesional calcium by intracoronary ultrasound depends on the histologic pattern.

This study was designed to examine the accuracy of intravascular ultrasound in detecting different histologic types of calcium pattern in human coronary artery atherosclerotic lesions. Previous studies have shown that calcium deposits in atherosclerotic lesions may occur in various forms and that intravascular ultrasound is a sensitive technique to detect calcium in atherosclerotic lesions. However, there has been no distinction between varying image representations of calcium and different histologic patterns of intralesional calcific deposits. Calcific lesions have an important clinical impact on the outcome of intracoronary transcatheter therapy, and the varying types of calcium may also play a role in the guidance of intracoronary interventions. Fifty fresh coronary vessel segments were studied by intracoronary ultrasound imaging and the images compared with the corresponding histologic sections. With intracoronary ultrasound imaging, calcium was defined as bright echo with corresponding sharp edged shadowing in the distal field. Three different histologic types of calcification were defined, and the sensitivity and specificity of the detection by intravascular ultrasound were determined for each type. Dense calcified plaques (type 1) were found 18 cases, microcalcification (small flecks of calcium) with single calcium fleck size < or = 0.05 mm (type 2) in 12 cases, and combination of calcified plaque surrounded by small calcium flecks (type 3) in 3 cases. In 17 (34%) coronary vessel segments, histologic analyses detected no calcium. Intracoronary ultrasound correctly detected 16 (89%) of 18 cases of type 1 calcification, 2 (17%) of 12 type 2, and all 3 (100%) type 3. Sensitivity for detection of type 1 and 3 calcification was 90%, with specificity of 100%.(ABSTRACT TRUNCATED AT 250 WORDS)

Calcium↗

Analysis of pulsed wave Doppler ultrasound spectra obtained from a model intracoronary catheter.

Abnormal arterial blood flow patterns have been implicated in the evolution of various vascular disease processes. Intravascular ultrasound techniques using the pulsed wave Doppler catheter offer the opportunity to characterize these abnormal flow patterns. We have developed a mathematical model that predicts the first two moments of the Doppler spectrum obtained using a Doppler catheter based on the distribution of ultrasonic beam power and velocity profile of fluid flow with an arbitrary distribution of flow disturbances. A scaled-up, in vitro experimental arterial system was used to confirm the validity of the model. Comparison of the predicted first two moments of the Doppler spectrum to the experimental values in this system demonstrated that the distribution of beam power significantly affects the magnitude of the first two moments. Additionally, both velocity gradient and velocity fluctuation broadening effects play prominent roles in determining the magnitude of the second moment. These phenomena must therefore be considered when evaluating in vivo Doppler spectra used for the characterization of abnormal flow patterns.

Analysis of Variance↗

Assessment of coronary conductance and resistance vessel reactivity in response to nitroglycerin, ergonovine and adenosine: in vivo studies with simultaneous intravascular two-dimensional and Doppler ultrasound.

OBJECTIVES: The aim of this study was to determine the differential effects of nitroglycerin, ergonovine and adenosine on the resistance vessels in vivo by using a Doppler-tipped guide wire in combination with an ultrasound imaging catheter. BACKGROUND: Catheter-based two-dimensional intravascular ultrasound yields images of the coronary arteries from which cross-sectional areas can be measured. Intravascular Doppler ultrasound techniques allow measurement of coronary blood flow velocity. The simultaneous use of the two techniques can yield anatomic and physiologic information on conductance and resistance vessels but has not been tried in the coronary arteries. METHODS: In 15 dogs, we studied coronary flow and vascular reactivity in response to pharmacologic agents using two approaches: 1) a 30-MHz, 4.3F imaging catheter placed alongside a 0.018-in. (0.046 cm) Doppler wire in the circumflex or left anterior descending coronary artery (n = 5); 2) the ultrasound imaging catheter introduced directly over a 0.014-in. (0.036 cm) Doppler wire (n = 10). Vasodilator and vasoconstrictor responses were studied by using intracoronary nitroglycerin (50, 100 and 200 micrograms), ergonovine (200 micrograms) and adenosine (6 mg). RESULTS: Nitroglycerin caused a dose-dependent increase in epicardial coronary artery cross-sectional area and, to a lesser extent, in average peak flow velocity, resulting in an increase in volumetric coronary blood flow of 39% and 50% at the doses of 100 and 200 micrograms, respectively. With these doses of nitroglycerin, the decrease in diastolic to systolic velocity ratio and the increased change in cross-sectional area from end-diastole to end-systole suggested an enhanced epicardial coronary artery compliance. With ergonovine, a 12% reduction in epicardial coronary artery cross-sectional area was seen, without a significant change in average peak velocity, resulting in a 15% decrease in volumetric coronary blood flow. Adenosine caused a 270% increase in average peak velocity but no change in epicardial coronary artery cross-sectional area, resulting in a 270% increase in volumetric blood flow. CONCLUSIONS: This study demonstrates that nitroglycerin and ergonovine predominantly influence coronary conductance arteries whereas adenosine mainly dilates coronary resistance vessels. These findings also demonstrate that the combined use of a two-dimensional and a Doppler ultrasound transducer within one catheter assembly can provide information on the differential effects of vasoactive agents on the epicardial and microvascular coronary circulation.

Adenosine↗

Intravascular ultrasound imaging of coronary arteries. Is three layers the norm?

BACKGROUND: The purpose of this study was to evaluate the significance of the three-layered appearance of coronary arteries in adolescence and adults from intravascular ultrasound scans and to correlate these observations with histopathology. METHODS AND RESULTS: Sixteen intact hearts were excised at autopsy from patients with no clinical history of coronary artery disease. The patients' ages ranged from 13 to 55 years. A 30-MHz ultrasound imaging catheter was used to obtain images throughout the epicardial coronary vasculature. A total of 72 image cross sections was marked by epivascular sutures, and the corresponding histological sections were examined. Ultrasound images were classified into two groups: images exhibiting three-layered appearance and images without distinct layering. Histological analysis revealed a significantly greater degree of intimal thickening in segments with three layers (243 +/- 105 microns) than in nonlayered segments (112 +/- 55 microns). Discriminant analysis of these data predicted the threshold between the two groups to be 178 microns. Measurements of medial thickness were not different between these two groups (235 +/- 61 versus 210 +/- 76 microns). In the nonlayered group, the average patient age was 27.1 +/- 8.5 years, whereas in the three-layered groups, the average age was 42.8 +/- 9.8 years. CONCLUSIONS: The intracoronary ultrasound image appearance of young, morphologically normal coronary artery walls is homogeneous without layering. A three-layered appearance suggests the presence of at least 178 microns of intimal thickening and is seen more frequently with advancing age.

Adolescent↗

Contribution of localized calcium deposits to dissection after angioplasty. An observational study using intravascular ultrasound.

BACKGROUND: Atherosclerotic plaque fracture and dissection of the arterial wall are frequent concomitants of the balloon angioplasty process. The composition and morphology of plaque within the vessel may be critical in determining the extent of plaque fracture and dissection during balloon angioplasty. To examine this potential association in the clinical setting, we studied patients with intravascular ultrasound imaging after balloon angioplasty. METHODS AND RESULTS: Forty-one patients were studied with intravascular ultrasound after angioplasty in both peripheral and coronary arteries. Ultrasound images representing the target lesion cross section were digitized, stored on computer, and analyzed off-line. The presence of intralesional calcium and the relative size of dissection for each lesion was computed. Thirty-one patients (76%) had ultrasound evidence of significant dissection or plaque fracture immediately after balloon dilation. In 23 of 31 (74%) of the lesions, the ultrasound scans showed significant localized calcium deposits within the plaque substance. In 87% of these cases, the dissections were adjacent to the calcific portion of the vessel wall. In addition, the relative size of dissections referenced to the neolumen area were significantly larger (p less than or equal to 0.002) in the calcified vessels (27.5 +/- 12.3%) compared with the size of the dissections in lesions without calcium (11.2 +/- 5.8%). CONCLUSIONS: The presence of calcium within the vessel wall appeared to be significantly associated with both the location and size of the dissected tissue arm from the vessel wall. These data suggest that localized calcium deposits have a direct role in promoting dissection, presumably by increasing shear stresses within the plaque.

Angioplasty, Balloon, Coronary↗

Detection of coronary atherosclerosis in young adult hearts using intravascular ultrasound.

BACKGROUND: Coronary atherosclerosis has been demonstrated in young adults by postmortem pathology. Angiographic evaluation of coronary disease in young adults is limited by ethical issues and the insensitivity of angiography for detecting early pathology. Catheter-based intracoronary ultrasound has proven useful both in detecting and quantitating coronary disease, but the ultrasound appearance of young, angiographically normal, coronary arteries has not been well defined. METHODS AND RESULTS: Twenty-five subjects were examined with intracoronary ultrasound within 1 month of cardiac transplantation. Mean age of the donor hearts was 28 years (range, 14-43 years). Measurements of an index of intimal thickening were obtained at four left anterior descending coronary artery sites in each patient. All study patients had angiographically normal coronary arteries. Ultrasound in 14 subjects demonstrated a three-layered appearance of the coronary vessel wall with a mean intimal index of 0.16 +/- 0.07. The other 10 subjects, including all donors under the age of 25 years, had coronary vessel wall layers too thin to be imaged separately at the 30-MHz sound frequency. Five subjects had ultrasound evidence of focal intimal thickening greater than 500 microns. The donors of these hearts each had risk factors for coronary artery disease. Two subjects died within 5 weeks of their ultrasound study. Histological measurements of the vessel wall layers were similar to the corresponding ultrasound values. CONCLUSIONS: This study provides a reference for the intravascular ultrasound appearance of young adult coronary arteries and confirms pathology findings that young subjects with angiographically normal vessels have a range of coronary intimal thickening, which includes occasional evidence of focal, early atheromatous lesions.

Adult↗

Intravascular ultrasound imaging for guidance of atherectomy and other plaque removal techniques.

Intravascular ultrasound imaging provides a direct view of atherosclerotic disease, generating in vivo information about the depth and mechanical characteristics of plaque at any point in the vessel wall. For this reason, ultrasound has significant potential to serve as a guidance modality for catheter-based techniques designed to remove or ablate plaque. Although the current generation mechanical atherectomy, laser ablation and ultrasound pulverization techniques all have some specificity for attacking plaque as opposed to normal vessel wall, it appears that in practice all of these devices will continue to carry a risk of traumatizing or even perforating arteries. In addition, it seems highly likely that aggressive 'debulking' of plaque will require some type of guidance beyond angiography - a role which ultrasound is theoretically well suited to play. The purpose of this review is to consider the theoretical and practical applications of ultrasound imaging as a guide to catheter-based plaque removal and ablation techniques. Specific uses will be discussed with respect to both directional and coaxial therapeutic devices.

Arteriosclerosis↗

Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography.

Intravascular ultrasound, a new technique for real-time two-dimensional visualization of arteries and veins, delineates vessel wall morphology and measures luminal dimensions. This imaging method has been validated with in vitro systems and in peripheral vessels, but there are few in vivo coronary artery studies. Twenty cardiac transplant recipients with no angiographic coronary artery disease were scanned with a 30-MHz intravascular ultrasound catheter from the left main coronary ostium to the mid-left anterior descending coronary artery. Simultaneous angiographic measurements were performed at 76 sites. Ultrasound end-diastolic diameters in two perpendicular axes were 3.8 +/- 0.9 and 3.9 +/- 0.6 mm, respectively, and mean diameter derived from an area determined by planimetry was 3.9 +/- 0.9 mm. Angiographic coronary artery diameters measured with a computer-assisted edge detection system perpendicular to the long axis of the vessel and to the long axis of the catheter were 3.4 +/- 0.8 and 3.6 +/- 0.8 mm, respectively. Luminal diameters measured with the two imaging systems correlated closely, with an r value of 0.86 when ultrasound was compared with the angiographic diameter measured perpendicular to the vessel and 0.88 when compared with the angiographic diameter measured perpendicular to the imaging catheter. Eighty-three percent of the ultrasound-measured diameters were above the line of identity when compared with the simultaneous angiographic measurement. The more the imaging catheter deviated from the long axis of the vessel, the greater was the discrepancy between the ultrasound and angiographic measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

Intravascular ultrasound guidance for catheter-based coronary interventions.

Intravascular ultrasound is a new method for visualizing the details of vascular pathology, providing high resolution images of plaque and thrombus. This review summarizes the potential applications of ultrasound imaging in the guidance of balloon angioplasty, atherectomy, laser ablation and stenting. Ultrasound differs from angiography and angioscopy in its ability to penetrate below the surface of the vessel lumen, demonstrating specific aspects about the distribution and composition of plaque. Because the different layers of the arterial wall have different acoustic properties, ultrasound catheters are able to define the layers of normal wall in comparison with plaque. Particularly in combination with therapeutic techniques designed to remove or ablate plaque, ultrasound may prove useful in maximizing the amount of plaque treated and minimizing trauma to normal vessel wall components. Combined imaging/therapeutic devices are in the pilot phase of development and show promise for enhancing the safety and efficacy of the catheter devices.

Angioplasty, Balloon, Coronary↗

Transvenous coronary ultrasound imaging. A novel approach to visualization of the coronary arteries.

BACKGROUND: Catheter-based ultrasound is a new imaging modality to examine endovascular detail in the coronary circulation. This technique requires direct placement of the catheter in the arterial segment of interest. METHODS AND RESULTS: We examined the feasibility of a less invasive approach by imaging the coronary arterial circulation by using a 5F (30 MHz) imaging catheter placed in the cardiac venous system. Using simultaneous fluoroscopy, we studied anesthetized closed-chest dogs (n = 6) and human subjects undergoing right heart catheterization (n = 11). After cannulation of the coronary sinus, the circumflex coronary artery (Cx) was visualized from the great cardiac vein (GCV), and on advancing the catheter into the anterior interventricular vein (AIV), the left anterior descending artery (LAD) was identified. Where artery and vein were parallel to each other, circular cross-sectional images of the coronary artery were obtained, whereas oblique and transverse orientation of artery to vein produced ellipsoid images or long-axis images. In the dogs, ultrasound-determined cross-sectional area of the coronary arteries (4.81 +/- 0.18 mm2) correlated closely with angiography (4.77 +/- 0.21 mm2) (r = 0.91, p less than 0.001). In humans, the Cx was readily visualized from the GCV in all subjects but because of anatomic variability, the LAD was seen less consistently from the AIV (73%). There was significant correlation between ultrasound-determined cross-sectional areas of the coronary arteries (8.25 +/- 0.34 mm2) with those from angiography (8.59 +/- 0.3 mm2) (r = 0.82, p = 0.001) in humans. In all subjects, the ultrasound transducer could be safely advanced into the AIV to the cardiac apex. Limitations of the technique include ultrasonic penetration problems, caused in part by the large size of human coronary veins and variability in artery-vein relations. CONCLUSIONS: We conclude that transvenous imaging of coronary arteries with intravascular ultrasound is a less invasive, promising new approach to the study of structure and morphology in the coronary vasculature.

Animals↗

Two-dimensional ultrasonic tissue characterization: backscatter power, endocardial wall motion, and their phase relationship for normal, ischemic, and infarcted myocardium.

To understand the possible differences in reflected ultrasonic energy from normal, ischemic, and infarcted myocardium, we studied 20 open-chest dogs with a commercially available two-dimensional ultrasonic scanner. Echocardiographic radiofrequency images of anterior myocardium were obtained serially during complete coronary occlusion for 2 hr (n = 15) or 5 hr (n = 10), or after temporary coronary clamping for 15 min with release for 1 hr (n = 5). We investigated two variables: the cyclic backscatter power and the phase difference among endocardial wall motion (EWM), cyclic backscatter power (BSP), and left ventricular pressure (LVP). The cyclic BSP decreased from a control (nonischemic) level of 5.1 +/- 0.8 to 2.3 +/- 0.7 dB during ischemia (up to 30 min after coronary ligation). The phase difference between the EWM and BSP progressed from a control (nonischemic) value of 38 +/- 20 to 115 +/- 23 degrees during ischemia. For the infarction period (2 to 5 hr after coronary ligation), the cyclic BSP progressively returned toward baseline control levels to 4.0 +/- 1.2 dB, but the phase had increased further to 170 +/- 28 degrees. The reperfusion study showed a similar decrease in cyclic BSP and an increase in phase after arterial clamping and both returned to near-normal nonischemic values upon arterial release. Simultaneous LVP recordings were performed to assess the phase contribution of endocardial dyskinesis to the total phase difference measurement. At 5 hr the dyskinesis had contributed 46% to the total phase difference, while the backscatter power contributed 54%. However, the EWM contribution occurred immediately while BSP contribution changed progressively during the 5 hr study period.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗