Pacemaker syndrome induced by the mode switching algorithm of a DDDR pacemaker.

A patient with marked first-degree AV block and a DDDR pacemaker presented with a history of paroxysmal narrow QRS tachycardia, subsequently identified as sinus tachycardia (with a very long PR interval), causing a clinical problem similar to pacemaker syndrome because of loss of AV synchrony. The latter resulted from an excessively long postventricular atrial refractory period (PVARP) that prevented sensing of sinus P waves. The unfavorable hemodynamics caused reflex sinus tachycardia. The long PVARP was mandated by the mode switching algorithm of this particular device and was automatically set according to the selected tachycardia detection rate. The patient became asymptomatic when the mode switching function was turned off and the PVARP shortened.

Algorithms↗

Radiofrequency catheter ablation of drug refractory symptomatic ventricular ectopy: short- and long-term results.

We performed radiofrequency catheter ablation (RFCA) in 12 consecutive patients (17-77 years) with daily, symptomatic, monomorphic ventricular ectopy (VE) (12,096 +/- 3,326 on 24-hour Holter) resistant to antiarrhythmic drugs. Nine patients had no apparent structural heart disease, 1 patient had a mild dilated cardiomyopathy, 1 patient had a treated mitral stenosis, and 1 patient had arrhythmogenic ventricular dysplasia. VE morphology was LBBB with inferior axis in 9 patients, RBBB with inferior axis in 2 patients, RBBB with superior axis in 1 patient. None of the patients had spontaneous or inducible sustained ventricular tachycardia. The VE focus was targeted with RF energy at the earliest endocardial activation site and based on a matching 12-lead ECG pace map. The VE focus was localized in the right outflow tract in 9 patients and on the left ventricle in 3 patients. RFCA was delivered with a standard 4-mm tip electrode. The ablation was initially successful in 11 patients and unsuccessful in 1 patient. All successfully ablated patients were asymptomatic and discharged without antiarrhythmic drugs. During follow-up (25 +/- 8; 17-38 months), two patients had a recurrence of symptoms, which were controlled by a previously ineffective drug. At the end of follow-up, 1,329 +/- 3198 VE were observed on Holter monitoring (P < 0.001 compared with initial values). No short- and long-term complications were observed. RFCA is a safe and effective method for treating drug-resistant symptomatic monomorphic VE in carefully selected patients. A persistent benefit without complications was obtained over a 2-year follow-up.

Adolescent↗

Local electrogram-based criteria of cavotricuspid isthmus block.

INTRODUCTION: The efficacy and outcome of cavotricuspid isthmus ablation guided by local electrogram-based criteria of linear block were prospectively assessed. METHODS AND RESULTS: In 40-consecutive patients (age 65+/-11 years) with typical right atrial (RA) flutter (cycle length = 255+/-31 msec), radiofrequency (RF) energy was delivered at electrograms in the isthmus coinciding with the center of the ECG plateau until termination of flutter, followed by local assessment of isthmus conduction during slow rate low-lateral RA pacing. 'Gaps' in the ablation line were located in the form of single or fractionated potentials centered on the isoelectric intervals of adjacent double potentials and ablated. Complete linear isthmus block was defined by the achievement of a complete corridor of parallel double potentials from the right ventricle to the inferior vena cava edge. Applications of 11+/-7 RF applications were required in all patients to achieve a complete line of double potentials separated by an isoelectric interval of 120+/-26 msec (range 60 to 190). After 6+/-3 RF applications, 6 (15%) patients had evidence of isthmus block using indirect RA activation sequence mapping without a complete line of double potentials. 5+/-5 further RF applications of eliminated local conduction and achieved complete linear block without altering descending septal RA activation. Conduction recovery occurred in 20 (50%) patients--1.85 times per patient-indicated by reversed changes in local electrograms eliminated by further ablation of the recovered gaps. After discharge, two recurrences (5%) occurred during a follow-up of 16+/-2 months. CONCLUSION: Double potential mapping is an effective assessment modality for local isthmus conduction. Slow conduction limited to the ablation line is observed during ablation in 15% of patients.

Adult↗

Diagnosis of Zollinger-Ellison syndrome. From symptoms to biological evidence.

With insulinoma, Zollinger-Ellison syndrome is one of the most common functional islet-cell tumour. Since it is a life-threatening condition, needing appropriate management, the diagnosis must be accurately established. This paper reviews the clinical situations leading to suspect the diagnosis and the biological tests, mainly the secretin test, that confirm the diagnosis. The different ways of performing the secretin test and the respective results are presented. This review will also focus on some aspects of the diagnosis of multiple endocrine neoplasia type 1 in these patients.

Age of Onset↗

Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.

BACKGROUND: Atrial fibrillation, the most common sustained cardiac arrhythmia and a major cause of stroke, results from simultaneous reentrant wavelets. Its spontaneous initiation has not been studied. METHODS: We studied 45 patients with frequent episodes of atrial fibrillation (mean [+/-SD] duration, 344+/-326 minutes per 24 hours) refractory to drug therapy. The spontaneous initiation of atrial fibrillation was mapped with the use of multielectrode catheters designed to record the earliest electrical activity preceding the onset of atrial fibrillation and associated atrial ectopic beats. The accuracy of the mapping was confirmed by the abrupt disappearance of triggering atrial ectopic beats after ablation with local radio-frequency energy. RESULTS: A single point of origin of atrial ectopic beats was identified in 29 patients, two points of origin were identified in 9 patients, and three or four points of origin were identified in 7 patients, for a total of 69 ectopic foci. Three foci were in the right atrium, 1 in the posterior left atrium, and 65 (94 percent) in the pulmonary veins (31 in the left superior, 17 in the right superior, 11 in the left inferior, and 6 in the right inferior pulmonary vein). The earliest activation was found to have occurred 2 to 4 cm inside the veins, marked by a local depolarization preceding the atrial ectopic beats on the surface electrocardiogram by 106+/-24 msec. Atrial fibrillation was initiated by a sudden burst of rapid depolarizations (340 per minute). A local depolarization could also be recognized during sinus rhythm and abolished by radiofrequency ablation. During a follow-up period of 8+/-6 months after ablation, 28 patients (62 percent) had no recurrence of atrial fibrillation. CONCLUSIONS: The pulmonary veins are an important source of ectopic beats, initiating frequent paroxysms of atrial fibrillation. These foci respond to treatment with radio-frequency ablation.

Adolescent↗

Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.

BACKGROUND: Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS: Of 170 patients referred for ablation of common atrial flutter, conventional ablation of the cavotricuspid isthmus with >21 applications failed to create a bidirectional block in 13 (7.6%). An irrigated-tip catheter ablation was performed on identified gaps in the ablation line according to a protocol found to be safe in animals: a moderate flow rate of 17 mL/min and temperature-controlled (target, 50 degrees C) RF delivery with a power limit of 50 W. Bidirectional isthmus block was achieved in 12 patients by use of a mean delivered power of 40+/-6 W with a single application in 6 patients and 2 to 6 applications in the other 6. No side effects occurred during or after the procedure. CONCLUSIONS: Irrigated-tip catheter ablation is safe and effective for achieving cavotricuspid isthmus block when conventional RF energy has failed.

Adult↗

Association of serum antibodies against p53 protein with poor survival in patients with Zollinger-Ellison syndrome.

BACKGROUND & AIMS: Long-term survival of patients with Zollinger-Ellison syndrome (ZES) is largely determined by the presence or absence of liver metastases. However, because of the lack of precision of these criteria, development of further indicators is still required. Recent evidence showing that autoantibodies directed against the p53 protein could predict poor survival for some types of cancers prompted us to investigate the presence of such antibodies in sera from patients with ZES and their potential value as survival indicator. METHODS: Anti-p53 antibodies were detected in the sera of 44 consecutive patients with ZES using both an enzyme-linked immunosorbent assay (ELISA) and Western blotting. The mean follow-up of these patients was 92 months. RESULTS: Anti-p53 antibodies were detected in 7 of the patients with ZES (16%) by both ELISA and Western blotting. Univariate and multivariate analyses showed that the presence of anti-p53 antibodies (P = 0.0009 and P = 0.017, respectively) and liver metastases (P = 0.0009 and P = 0.012, respectively) was independently associated with shorter survival. CONCLUSIONS: These results suggest that anti-p53 antibodies are an indicator of survival and could be used in combination with staging to determine which patients with ZES have poor prognoses and therefore require reinforced therapy.

Adult↗

Absence of somatic alterations of the EB1 gene adenomatous polyposis coli-associated protein in human sporadic colorectal cancers.

The human EB1 gene product was recently found, by a yeast two-hybrid screening, to be associated with the carboxy terminus of the APC (adenomatous polyposis coli) protein, the product of a tumour-suppressor gene thought to act as a gatekeeper in colorectal carcinogenesis. Because virtually all of the APC mutations result in the synthesis of carboxy-terminal truncated proteins, mutant APC proteins are expected to lose their ability to interact with EB1 gene product. Thus, the interaction between APC and EB1 proteins may be important for the tumour-suppressor activity of APC protein, and raises the hypothesis that EB1 is also involved in sporadic colorectal tumorigenesis. To investigate this hypothesis, somatic mutations in the entire coding sequence of EB1 cDNA were searched by reverse transcriptase single-strand conformational polymorphism (SSCP) analysis in 21 sporadic colorectal cancers and seven adenomas. None of these tumours contained somatic mutation, whereas a silent cDNA variant was identified in 14% of alleles. Furthermore, to investigate whether EB1 locus was included within a region subjected to losses of heterozygosity, four polymorphism markers surrounding EB1 locus were surveyed. Only one out of 28 colorectal tumours contained a loss of heterozygosity at the D20S107 marker. In conclusion, the present findings strongly suggest that EB1 gene is not involved in somatic colorectal carcinogenesis.

Adenomatous Polyposis Coli↗

Scoring method for assessing rate adaptive pacemakers: application to two different activity sensors.

To optimize programming of rate adaptive pacemakers (RAPs), we explored a new mathematical method to assess the performance of RAPs during daily-life tests, using customized Windows-based software. By stepwise discriminant analysis and linear regression, this method allows calculation of the acceleration and deceleration capacity of pacemakers and their general behavior during effort and recovery phases. Twenty-three patients (10 females and 13 males; 68 +/- 8 years) with chronic atrial fibrillation and a slow ventricular response were evaluated. They randomly received an accelerometer-controlled VVIR Dash Intermedics pacemaker (10 patients) or a vibration piezoelectric-controlled VVIR Sensolog III Siemens pacemaker (13 patients). All patients underwent the same test protocol: 6 minutes walking, 1.5 minutes climbing stairs, 1.5 minutes descending stairs, and 0.5 minutes sit-ups. By definition, the pacemaker responsiveness slope was programmed so that the heart rate response of paced patients during the walking test corresponded best to that of healthy controls. The slope was left unchanged for the other tests. We considered four scores: an acceleration score (EA score), an effort rate score (ER score), a deceleration score (RD score), and a recovery rate score (RR score). Scores ranged from -10 (hypochronotropic behavior of the pacemaker) to +10 (hyperchronotropic behavior), based on daily-life tests of 15 healthy controls (7 females and 8 males, 65 +/- 9 years). A score of 0 represented exact concordance with healthy controls. During stair descent, the Sensolog III produced excessive acceleration (EA score = +2.9 +/- 1.1) compared to: (1) stair climbing (EA score = -4.0 +/- 1.9; P = 0.01, with the same pacemakers); and (2) the Dash (+1.8 +/- 1.9; P = 0.04) and healthy controls (P = 0.02). The sit-up tests revealed a hypochronotropic response of both pacemakers compared to healthy controls, with a larger difference for the Sensolog III (EA score = -2.0 +/- 5.8; P = 0.04; RD score = -6.8 +/- 3.8' P = 0.02). We conclude that activity-driven pacemakers can accommodate brief activities, except for isovolumetric exercise such as sit-ups. During daily activities, accelerometer-driven pacemakers seem to provide a heart rate resoibse closer to that of healthy controls. Our new mathematical analysis is a simple and reproducible method for evaluating and quantifying the efficacy of any sensor-driven pacemaker.

Adaptation, Physiological↗

Prevention of atrial arrhythmias during DDD pacing by atrial overdrive.

We evaluated the effect of atrial overdrive on the incidence of atrial arrhythmias (AA) in 22 patients (67 +/- 9 years, 7 women, 15 men) with Chorus 6234 DDD pacemakers. Atrial overdrive was defined as a programmed paced rate 10 ppm faster than the mean ventricular rate stored for the last 24-hour period in the pacemaker memory. The protocol consisted of three phases of 1 month each. Phase I: observation after discontinuation of antiarrhythmic therapy. Phase II: arrhythmia analysis using the pacemaker memory after programming the lower rate to 55 ppm. The fallback function and histogram data were used to document the number and maximal duration of AA episodes as well as the total AA time in a month. Phase III: atrial overdrive. The mean ventricular heart rate was 65 +/- 4 beats/min before atrial overdrive versus 75 +/- 5 with atrial overdrive (P = 0.02). At the end of phase II, all patients presented with AA episodes (mean number per patient: 42 +/- 78 in one month). In phase III (with atrial overdrive), 14 (64.6%) patients had no recorded AA (group A). In the other eight patients with persistent AA episodes in phase III (group B), there was a significant reduction in the number of AA episodes (90 +/- 106 in phase II vs 38 +/- 87 in phase III; P = 0.01), their total duration (166 +/- 115 in phase II vs 92 +/- 134 hours in phase III; P = 0.03) and their maximal duration (121 +/- 103 in phase II vs 85 +/- 89 min; P = 0.04). Our short-term data suggest that atrial overdrive prevents or reduces AA episodes and demonstrate the feasibility and need of long-term studies to determine whether this benefit is sustained.

Aged↗

Endocardial biventricular pacing.

Simultaneous right and left ventricular pacing was performed in a 73-year-old man with coronary artery disease end-stage congestive heart failure and a DDD pacemaker implanted for sick sinus syndrome. An endocardial LV lead was introduced transseptally after unsuccessful attempts to enter the coronary sinus. This new approach for multisite pacing offers an alternative to epicardial LV from the coronary sinus or by thoracotomy.

Aged↗

Long-term follow-up after right atrial radiofrequency catheter treatment of paroxysmal atrial fibrillation.

UNLABELLED: Catheter ablation of paroxysmal atrial fibrillation using long linear lesions in the right atrium is still under investigation, and its long-term follow-up is unknown. METHODS: Thirty-six men and nine women (aged 51 +/- 12 years) with symptomatic daily episodes of AF for 6 +/- 5 years despite the use of 4.7 +/- 1.5 antiarrhythmic drugs were studied between July 1994 and January 1996. Progressively longer ablation lines were performed in 3 groups of 15 consecutive patients each, using a 14-electrode catheter or a single-electrode dragging technique. Success was defined as atrial fibrillation elimination or recurrence for no longer than 6 hours over 3 months of observation. Patients who had fewer than 6 hours of atrial fibrillation per month were considered "improved." Medium- (11 +/- 4 months) and long-term (26 +/- 5 months) results were assessed clinically from a patient's diary and from Holter recordings. RESULTS: After a follow-up of 11 months, 24 patients had a favorable result of the ablation procedure with or without additional antiarrhythmic drug therapy, representing 53% of the original cohort. After 26 +/- 5 months of follow-up, these successful results were reduced to 17 patients (37%). CONCLUSIONS: After linear atrial ablation, a significant long-term attrition of arrhythmia-free patients was observed. This may be due to a combination of disease progression, incomplete linear block, and ineffective ablation of arrhythmogenic triggers.

Atrial Fibrillation↗

Segment by segment linear ablation with an articulated bilimb catheter: initial experimental results.

Transcatheter radiofrequency (RF) ablation of atrial fibrillation or flutter requires the creation of linear lesions. However, conventional catheters are not predictably effective because of poor endocardial contact, and limited lesion size and penetration. The purpose of the study was to assess in the right atrium, the efficacy and safety of a new catheter designed to create long myocardial tissue lesions using RF energy. The main characteristics of this 8 Fr deflectable RF ablation catheter were: (1) a perpendicularly contacting articulated bilimb electrodes ensuring stable and firm endocardial firm contact; and (2) an irrigated planar interface. Three different electrode prototypes were tested. Fourteen anesthetized sheep weighing 61 +/- 7 kg underwent RF ablation in the right atrium using three incremental power levels (25 to 45, 50, 55 to 75 W) with the aim of creating fully transmural (FT) lesions, defined as continuous and complete epicardial and endocardial lesion imprints. The animals were euthanized 1 hour later for macroscopic and histologic examinations. Forty-three of the 80 right atrial lesions created, in smooth as well as in trabeculated areas, were FT. The percentage of FT lesions increased with the applied power from 37% with 25-45 W, to 49% with 50 W, and up to 86% for 55-75 W. In all but two cases, histologic examination showed no discontinuity between FT lesions produced by both limbs resulting in 19 coalescent linear lesions with an average size of 25 x 6 x 4 mm (length x width x depth). In situ bipolar electrograms after ablation in the FT group showed split potentials and/or a marked decrease in amplitude from 2.85 +/- 1.79 to 0.33 +/- 0.14 mV (P = 0.001) accompanied by near complete disappearance of unipolar electrograms. There was no perforation due to RF ablation. In conclusion, continuous and FT lesions can be achieved in various areas of sheep atria, including the trabecular right atrium, with a perpendicularly contacting bilimb electrode catheter. It represents a promising tool for catheter ablation of atrial fibrillation and flutter.

Animals↗

Specific electrocardiographic features of manifest coronary vein posteroseptal accessory pathways.

INTRODUCTION: Some posteroseptal accessory pathways (APs) can be successfully ablated by radiofrequency current only from inside the coronary sinus (CS) or its branches, because of an absolute or relatively epicardial location. The aim of this study was to identify ECG features of manifest posteroseptal APs requiring ablation in the CS or the middle cardiac veins (MCVs). METHODS AND RESULTS: One hundred seventeen consecutive patients with manifest posteroseptal APs successfully ablated: (1) > or = 1 cm deep inside the MCV (group MCV: n = 13); (2) inside the CS, including the area adjacent to the MCV ostium (group CS: n = 10); (3) at the right (group R: n = 60); or (4) the left posteroseptal endocardial region (group L: n = 34) were included. We reviewed delta wave polarity (initial 40 msec) and QRS morphology during sinus rhythm and atrial pacing as well as electrogram characteristics in these patients. The local target site electrogram in groups MCV and CS was characterized by a longer atrial to ventricular electrogram interval, suggesting a longer course of the pathway and more frequent recording of a presumptive AP potential compared to the group ablated at the right or left endocardium. The most sensitive ECG feature for group CS or group MCV was a negative delta wave in lead II in sinus rhythm (87%), but specificity (79%) and positive predictive value (50%) were relatively low. A steep positive delta wave in aVR during maximal preexcitation possessed the highest specificity and positive predictive value (98% and 88%, sensitivity 61%) which increased to 99% and 91%, respectively, when combined with a deep S wave in V6 (R wave < or = S wave). CONCLUSION: These data suggest that posteroseptal APs ablated inside the coronary venous system have highly specific features, including the combination of a steep positive delta wave in lead aVR and a deep S wave in lead V6 (R wave < or = S wave) during maximal preexcitation. The highest sensitivity is provided by a negative delta wave in lead II. These findings may be helpful for anticipating and planning an epicardial ablation strategy.

Adolescent↗

Three-dimensional mapping of the common atrial flutter circuit in the right atrium.

BACKGROUND: The full circuit of common atrial flutter using conventional methods of sequential or multielectrode activation mapping is not completely understood. METHODS AND RESULTS: We performed three-dimensional right atrial endocardial activation mapping during common counterclockwise atrial flutter in 17 patients (16 men, 1 woman; mean age, 53+/-11 years) by using the Cordis-Biosense EP Navigation system and assessed the distribution of estimated conduction velocities and double and fractionated potentials. ECG flutter wave morphologies were compared with activation patterns. Points (91+/-29) were sequentially acquired covering 88+/-11% of the flutter cycle length of 239+/-22 ms. A wide and variable posterior zone of double and fractionated potentials coincided with blocking and colliding wave fronts and formed the posterior limit of the circuit. A progressively widening septal (sep) wave front ascending from just beyond the coronary sinus ostium, passed cranially as a broad front anterior to the superior vena cava (SVC) in 14 patients, whereas fusion around the SVC formed the superior (sup) limb of the circuit in 3. Bounded anteriorly by the tricuspid valve, the wave front descended down the lateral (lat) aspect of the right atrium before completing the circuit in all cases through the inferior vena cava-tricuspid annulus isthmus. The estimated conduction velocity in the medial isthmus (0.6+/-0.3 m/s) was lower than in the other limbs of the circuit (sup=1+/-0.5 m/s, lat=1+/-0.5 m/s, sep=0.9+/-0.4 m/s, P=.05). Double and fractionated potentials were constant and more prevalent in the posterior right atrium. ECG flutter wave morphology did not correlate with three-dimensional activation maps. CONCLUSIONS: Interindividual variations occur in the right atrial circuit of common atrial flutter, with constant activation through the cavotricuspid isthmus. A variable zone of block forms the posterior limit. Fusion around the SVC can occur, and ascending medial septal activation does not follow a consistent pattern.

Adult↗

Simplified electrophysiologically directed catheter ablation of recurrent common atrial flutter.

BACKGROUND: Despite verification of bidirectional conduction block after radiofrequency (RF) catheter ablation in the inferior vena cava (IVC)-tricuspid annulus (TA) isthmus, recurrence of common atrial flutter is relatively common. Although complete linear reablation is usually performed, we evaluated a simplified electrophysiological strategy selectively targeting recovered conducting isthmus tissue. METHODS AND RESULTS: Twenty-one patients (18 men and 3 women, age, 54+/-10 years) with a recurrence of typical atrial flutter 6+/-7 months after an apparently successful catheter ablation in the IVC-TA isthmus prospectively underwent electrophysiologically targeted reablation during flutter. Sites with narrow electrograms or fractionated electrograms interposed between adjacent sites with double potentials considered to represent gaps were ablated without movement of the catheter. Mapping showed that 18 of 21 patients had a single gap. Successful ablation required a single application in 14 patients and, in the group as a whole, a median of one application (mean, 2+/-2; range, 1 to 11) with resultant bidirectional block in 13 of 16. A single narrow electrogram (duration, 48+/-6 ms; amplitude, 0.1+/-0.05 mV) was noted at the successful site in 11, whereas a fractionated electrogram (97+/-32 ms, 0.05+/-0.04 mV, P<.05) was noted in 9. There were four additional recurrences during a follow-up at 7+/-5 months; three were similarly ablated with a median of one pulse. CONCLUSIONS: Transmural ablation lesions in the isthmus can be recognized during flutter by double potentials separated by an isoelectric interval. Postablation recurrent flutter is usually due to a single discrete recovered gap; this is represented by a single or a fractionated potential spanning the isoelectric interval of adjacent double potentials, which can be selectively targeted to minimize repeat ablation.

Adult↗