PubMed Health⌕ Search

Biomedical subjects

P Kapnoudhis

Publications and source records attributed to P Kapnoudhis.

4 recordsLinked to original sources

On line ST-segment analysis for detection of myocardial ischaemia during and after coronary revascularization.

PURPOSE: A paucity of information exists to validate the accuracy and reliability of ECG monitoring in the operating room or ICU. The purpose of this study was to determine the accuracy, sensitivity, specificity, and predictive values of the Marquette ECG monitor for detection of perioperative myocardial ischaemia (PMI) as measured by ST segment changes in a high risk population. METHODS: Monitoring for PMI in 28 patients scheduled for aortocoronary bypass surgery was done with the Cardiodata PR ambulatory continuous electrocardiography (ACECG) monitor lead V5, and compared with lead V5 of the Marquette Series 7000 ECG/Surgical operating room monitor, and ECG/Resp ICU monitor. The Marquette lead V5 was evaluated using current criteria for the assessment of diagnostic tests including concordance, sensitivity, specificity, positive and negative predictive values, false positive and false negative rates and compared with the ACECG monitor which served as the reference or "gold standard." Agreement beyond chance between the two methods was assessed using the Kappa statistic. RESULTS: Of the 53 observation data points, 27 were defined as ischaemic episodes by ACECG. Concordance between lead V5 in each system was 83% (44/53 episodes). Discordance was 17% (9/53 episodes), predominantly in the postbypass interval (77%, 7/9; P = 0.0184). The incidences of false negatives and false positives for Marquette lead V5 was 26% (7/27) and 7.7% (2/26), respectively. The sensitivity and specificity of the Marquette was 0.74 and 0.92. Positive predictive value was 0.91, negative predictive value was 0.77, and Kappa statistic was 66%. CONCLUSION: Automated ST segment analysis with the Marquette Series 7000 monitoring system demonstrates good diagnostic accuracy, moderate sensitivity, and high specificity. However, clinically significant false negative and false positive rates of ischaemia detection are associated with its use, especially in the postoperative period.

Electrocardiography↗

Exposure to N2O.

Explore the source record for details and available documents.

Air Pollutants, Occupational↗

Continuous lumbosacral block using a Tuohy needle and catheter technique.

Three cases are reported where continuous lumbosacral block was performed using a catheter through an epidural needle technique. Good unilateral lower limb surgical anaesthesia was achieved in all three cases with successful blockade of the lumbar and sacral plexuses. A 17-gauge Tuohy needle was positioned between the transverse processes of L4 and L5 and an epidural catheter inserted into the space between the quadratus lumborum and psoas muscles. Forty to seventy millilitres of local anaesthetic were injected and resulted in good surgical anaesthesia within 12-20 min. Radiographic studies in these patients confirmed placement of the catheter in close proximity to the lumbosacral plexus. Experience in a further 12 cases is also reported. There were no side-effects. The technique is successful and is recommended when unilateral lower limb anaesthetic is required and when spinal and epidural anaesthesia are contraindicated.

Aged↗