PubMed Health⌕ Search

Biomedical subjects

P Kellman

Publications and source records attributed to P Kellman.

5 recordsLinked to original sources

Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE.

Parallel imaging applied to first-pass, contrast-enhanced cardiac MR can yield greater spatial coverage for a fixed temporal resolution. The method combines rate R=2 acceleration using TSENSE with shot-to-shot interleaving of two slices. The square root R SNR loss is largely compensated for by a longer effective repetition time (TR) and increased flip angle associated with slice interleaving. In this manner, increased spatial coverage is achieved while comparable or better image quality is maintained. Single-heartbeat temporal resolution was accomplished with spatial coverage of eight slices at heart rates up to 71 bpm, six slices up to 95 bpm, and four slices up to 143 bpm. Experiments in normal subjects (N=6) were performed to assess signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values.

Artifacts↗

Fluctuation analysis of mitochondrial NADH fluorescence signals in confocal and two-photon microscopy images of living cardiac myocytes.

A fluctuation analysis was performed on the reduced nicotine adenine dinucleotide (NADH) fluorescence signal from resting rabbit myocytes using confocal and two-photon microscopy. The purpose of this study was to establish whether any co-ordinated biochemical processes, such as binding, metabolism and inner mitochondrial membrane potential, were contributing to NADH signal fluctuations above background instrument noise. After a basic characterization of the instrument noise, time series of cellular NADH fluorescence images were collected and compared with an internal standard composed of NADH in the bathing medium. The coefficient of variation as a function of mean signal amplitude of cellular NADH fluorescence and bathing media NADH was identical even as a function of temperature. These data suggest that the fluctuations in cellular NADH fluorescence in resting myocytes are dominated by sampling noise of these instruments and not significantly modified by biological processes. Further analysis revealed no significant spatial correlations within the cell, and Fourier analysis revealed no coherent frequency information. These data suggest that the impact of biochemical processes, which might affect cellular NADH fluorescence emission, are either too small in magnitude, occurring in the wrong temporal scale or too highly spatially localized for detection using these standard optical microscopy approaches.

Animals↗

Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

A number of different methods have been demonstrated which increase the speed of MR acquisition by decreasing the number of sequential phase encodes. The UNFOLD technique is based on time interleaving of k-space lines in sequential images and exploits the property that the outer portion of the field-of-view is relatively static. The differences in spatial sensitivity of multiple receiver coils may be exploited using SENSE or SMASH techniques to eliminate the aliased component that results from undersampling k-space. In this article, an adaptive method of sensitivity encoding is presented which incorporates both spatial and temporal filtering. Temporal filtering and spatial encoding may be combined by acquiring phase encodes in an interleaved manner. In this way the aliased components are alternating phase. The SENSE formulation is not altered by the phase of the alias artifact; however, for imperfect estimates of coil sensitivities the residual artifact will have alternating phase using this approach. This is the essence of combining temporal filtering (UNFOLD) with spatial sensitivity encoding (SENSE). Any residual artifact will be temporally frequency-shifted to the band edge and thus may be further suppressed by temporal low-pass filtering. By combining both temporal and spatial filtering a high degree of alias artifact rejection may be achieved with less stringent requirements on accuracy of coil sensitivity estimates and temporal low-pass filter selectivity than would be required using each method individually. Experimental results that demonstrate the adaptive spatiotemporal filtering method (adaptive TSENSE) with acceleration factor R = 2, for real-time nonbreath-held cardiac MR imaging during exercise induced stress are presented.

Algorithms↗

Ghost artifact cancellation using phased array processing.

In this article, a method for phased array combining is formulated which may be used to cancel ghosts caused by a variety of distortion mechanisms, including space variant distortions such as local flow or off-resonance. This method is based on a constrained optimization, which optimizes SNR subject to the constraint of nulling ghost artifacts at known locations. The resultant technique is similar to the method known as sensitivity encoding (SENSE) used for accelerated imaging; however, in this formulation it is applied to full field-of-view (FOV) images. The method is applied to multishot EPI with noninterleaved phase encode acquisition. A number of benefits, as compared to the conventional interleaved approach, are reduced distortion due to off-resonance, in-plane flow, and EPI delay misalignment, as well as eliminating the need for echo-shifting. Experimental results demonstrate the cancellation for both phantom as well as cardiac imaging examples.

Artifacts↗

Low-latency temporal filter design for real-time MRI using UNFOLD.

To improve real-time control of interventional procedures such as guidance of catheters, monitoring of ablation therapy, or control of dosage during drug delivery, the image acquisition and reconstruction must be high speed and have low latency (small time delay) in processing. A number of different methods have been demonstrated which increase the speed of MR acquisition by decreasing the number of sequential phase-encodes. A design and implementation of the UNFOLD method which achieves the desired low latency with a recursive temporal filter is presented. The recursive filter design is characterized for this application and compared with more commonly used moving average filters. Experimental results demonstrate low-latency UNFOLD for two applications: 1) high-speed, real-time imaging of the heart to be used in conjunction with cardiac interventional procedures; and 2) the injection of drugs into muscle tissue with contrast enhancement, i.e., monitoring needle insertion and injection of a drug with contrast enhancement properties. Proof-of-concept was demonstrated by injecting a contrast agent. In both applications the UNFOLD technique was used to double the frame rate.

Animals↗